TITLE

Clinical and Radiographic Results of Metal-on-Metal Hip Resurfacing with a Minimum Ten-Year Follow-up

AUTHOR(S)
Amstutz, Harlan C.; Le Duff, Michel J.; Campbell, Patricia A.; Gruen, Thomas A.; Wisk, Lauren E.
PUB. DATE
November 2010
SOURCE
Journal of Bone & Joint Surgery, American Volume;11/17/2010, Vol. 92-A Issue 16, p2663
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: There was a need for information about the long-term performance of the modern generation of hip resurfacing implants. A retrospective review of the first 100 hips that had implantation of one resurfacing design and had been followed for a minimum often years was performed. Methods: Between 1996 and 1998, 100 CONSERVE PLUS hip resurfacing devices were implanted by a single surgeon in eighty-nine patients. The mean age of the patients was 49.1 years, and fifty-nine patients were male. Primary osteoarthritis was the etiology for sixty-four hips. All patients were assessed clinically and radiographically. Results: The mean duration of follow-up was 11.7 years (range, 10.8 to 12.9 years). Two patients were lost to follow-up, and five patients died of causes unrelated to the surgery. Eleven hips had conversion to total hip arthroplasty because of loosening of the femoral component (eight), a femoral neck fracture (one), recurrent subluxation (one), and late infection (one). The Kaplan-Meier survivorship was 88.5% at ten years. None of the resurfacing arthroplasties failed in the twentyeight hips that had a femoral component of >46 mm and no femoral head cystic or necrotic defects of >1cm. Five hips had narrowing of the femoral neck, three had radiolucent zones interpreted as osteolysis, and twenty had signs of neck-socket impingement. Five hips had radiolucencies around the metaphyseal stem (two partial and three complete) that had been stable for 7.8 to 10.2 years. The mean scores on the University of California at Los Angeles (UCLA) system at the time of the latest follow-up were 9.5 points for pain, 9.3 points for walking, 8.9 points for function, and 6.8 points for activity; the mean scores on the physical and mental components of the Short Form-12 (SF42) were 47.3 and 50.5 points, respectively; and the mean Harris hip score was 90 points. Conclusions: The results of the present series constitute a reference point to which subsequent series should be compared. These ten-year results in a group of young patients are satisfactory, and the low rate of osteolysis is encouraging, but longer follow-up is required for comparison with conventional total hip arthroplasty.
ACCESSION #
55513451

 

Related Articles

  • Medium-term analysis of modern ceramic-on-ceramic bearing in THA. ALDRIAN, SILKE; NAU, THOMAS; GILLESBERGER, FELIX; PETRAS, NINA; EHALL, REINHARD // Hip International;Jan-Mar2009, Vol. 19 Issue 1, p36 

    A variety of different bearing surfaces have been used to avoid osteolysis following hip replacement. We report a retrospective review of medium-term results of a modern ceramic-ceramic bearing (Biolox®, CeramTec, Plochingen, Germany) and uncemented components (Alpha Cera Fit®...

  • Impingement Between the Acetabular Cup and the Femoral Neck After Hip Resurfacing Arthroplasty. Myung Chul Yoo; Yoon Je Cho; Young Soo Chun; Kee Hyung Rhyu // Journal of Bone & Joint Surgery, American Volume;5/4/2011 Supplement, Vol. 93-A, p99 

    Background: Loosening, femoral neck fracture, and metal ion release have been well documented after hip resurfacing arthroplasty, but impingement between the acetabular cup and the femoral neck has not. The goal of this study was to analyze radiographic findings that were presumed to represent...

  • The Ringloc liner compared with the Hexloc liner in total hip arthroplasty. Sköldenberg, Olof; Salemyr, Mats; Muren, Olle; Johansson, Åke; Ahl, Torbjörn; Bodén, Henrik // Orthopedic Reviews;2009, Vol. 1, p21 

    The aim of this study was to compare the 10- year survival rate, pelvic osteolysis frequency and linear head penetration rate of the Hexloc and Ringloc liners used together with a partially threaded porous and hydroxyapatite coated cup and the Bi-Metric uncemented femoral stem. The 15-year...

  • Optimizing for head height, head offset, and canal fit in a set of uncemented stemmed femoral components. KHMELNITSKAYA, E.; MOHANDAS, P.; WALKER, P. S.; MUIRHEAD-ALLWOOD, S. K. // Hip International;Oct-Dec2008, Vol. 18 Issue 4, p286 

    When inserting an uncemented hip stem, the objectives are to obtain a close fit of the stem in the canal and anatomic head placement. Our goals were to formulate a set of stems which would satisfy these two objectives, and to test the resulting templates on sequential radiographs of hip...

  • The Biology of Aseptic Osteolysis. G Holt // Clinical Orthopaedics & Related Research;Jul2007, Vol. 460 Issue 1, p240 

    Total hip arthroplasty is one of the most commonly performed and successful elective orthopaedic procedures. However, numerous failure mechanisms limit the long-term success including aseptic osteolysis, aseptic loosening, infection, and implant instability. Aseptic osteolysis and subsequent...

  • Modular Femoral Sleeve and Stem Implant Provides Long-term Total Hip Survivorship. Le, David; Smith, Karen; Tanzer, Dylan; Tanzer, Michael // Clinical Orthopaedics & Related Research;Feb2011, Vol. 469 Issue 2, p508 

    Background: A femoral implant with a modular sleeve and stem has been designed to allow independent and complete metaphyseal-diaphyseal fit and fill as well as independent rotation to accommodate anteversion at the time of THA. Questions/purposes: In a prospective study we asked whether such a...

  • Nine years follow-up of 100 ceramic-on-ceramic total hip arthroplasty. Chevillotte, Christophe; Pibarot, Vincent; Carret, Jean-Paul; Bejui-Hugues, Jacques; Guyen, Olivier // International Orthopaedics;Nov2011, Vol. 35 Issue 11, p1599 

    The aim of this study was to evaluate the first 100 cementless ceramic-on-ceramic total hip arthroplasty (THA) performed at our institution with more than nine years of follow-up. Clinical evaluation was performed using Harris hip score. Radiological evaluation was performed by two surgeons....

  • Ceramic-on-Ceramic Total Hip Arthroplasty: Incidence of Instability and Noise. Schroder, David; Bornstein, Lindsey; Bostrom, Mathias P. G.; Nestor, Bryan J.; Padgett, Douglas E.; Westrich, Geoffrey H. // Clinical Orthopaedics & Related Research;Feb2011, Vol. 469 Issue 2, p437 

    Background: Alternative bearing materials in THA have been developed to reduce the incidence of osteolysis. Alumina-on-alumina bearings exhibit extremely low wear rates in vitro, but concerns exist regarding component impingement with the potential for dislocation and the occurrence of noise....

  • Cement mantle defects in total hip arthroplasty: influence of stem size and cementing technique. A. Katzer; A. Ince; M. Hahn; M. Morlock; W. Steens // Journal of Orthopaedics & Traumatology;Dec2007, Vol. 8 Issue 4, p167 

    Abstract  The cause of isolated osteolysis in the femoral shaft around stem implants in patients with cemented THR has so far not been established. A number of factors have been considered such as torsional stability of the femoral stem implant, the time of reduction...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics