TITLE

Comparison Between Standard and High-Flexion Posterior- Stabilized Rotating- Platform Mobile-Bearing Total Knee Arthroplasties

AUTHOR(S)
Won Chul Choi; Sahnghoon Lee; Sang Cheol Seong; Jong Hun Jung; Myung Chul Lee
PUB. DATE
November 2010
SOURCE
Journal of Bone & Joint Surgery, American Volume;11/17/2010, Vol. 92-A Issue 16, p2634
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: A high-flexion posterior-stabilized rotating-platform mobile-bearing prosthesis was designed in an attempt to improve the range of motion after total knee arthroplasty without compromising the theoretical advantages of the posterior-stabilized rotating-platform mobile-bearing system. The aim of this study was to compare the outcomes of standard and high-flexion posterior-stabilized rotating-platform mobile-bearing total knee arthroplasties. Methods: One hundred and seventy knees were randomly allocated to receive either a standard (n = 85) or a high-flexion (n = 85) posterior-stabilized rotating-platform mobile-bearing prosthesis and were followed prospectively fora minimum of two years. Ranges of motion, functional outcomes determined with use of standard scoring systems, and radiographic measurements were assessed. In addition, patients' abilities to perform activities requiring deep knee flexion and patient satisfaction were evaluated with use of questionnaires. Results: The average postoperative maximal flexion was 1300 for the knees with the standard design and 128° for those with the high-flexion design, and the difference was not significant. The two prosthetic designs also did not differ significantly with regard to the Knee Society scores; Hospital for Special Surgery (HSS) scores; or the scores on the pain, stiffness, and function subscales of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). In addition, the numbers of knees able to perform deep-flexion-related activities and the rates of patient satisfaction were similar in the two study groups. Conclusions: This prospective randomized study revealed no significant differences between standard and high-flexion posterior-stabilized rotating-platform mobile-bearingtotal knee prostheses in terms of clinical or radiographic outcomes or range of motion at a minimum of two years postoperatively.
ACCESSION #
55513448

 

Related Articles

  • In vivo stability of total knee arthroplasty using a navigation system. Jong Seon; Eun Song; Taek Yoon; Bong Bae; Sang Park; Sang Cho // International Orthopaedics;Feb2007, Vol. 31 Issue 1, p45 

    Abstract??The aim of this study was to evaluate in vivo stability for mediolateral laxity in extension and anteroposterior laxity in 90? of flexion and to correlate these and the range of motion (ROM) in 42 total knee arthroplasties (TKA) performed using a navigation system, with a minimum...

  • Three- to six-year follow-up results after high-flexion total knee arthroplasty: can we allow passive deep knee bending? Sung-Do Cho; Yoon-Seok Youm; Ki-Bong Park // Knee Surgery, Sports Traumatology, Arthroscopy;Jun2011, Vol. 19 Issue 6, p899 

    Purpose: We evaluated 3- to 6-year clinical and radiological follow-up results after NexGen LPS-flex total knee arthroplasty (TKA). Methods: A retrospective evaluation was undertaken of 218 knees in 166 patients (22 males, 144 females) who were followed up for more than 3 years after TKA....

  • Is Knee Range of Movement on Discharge Important After Total Knee Replacement - A prospective audit based study. Darch, Ross; Swan, Jonathan; Wainwright, Tom; Middleton, Robert // Indian Journal of Physiotherapy & Occupational Therapy;Jul-Sep2011, Vol. 5 Issue 3, p10 

    Questions: Is knee range of movement on discharge important after total knee replacement? Is there a difference in flexion over 6 weeks post TKR between sub-groups based on varying flexion scores on discharge? Design: A prospective audit utilising a repeated measures design was adopted, using a...

  • Total knee arthroplasty treatment of active tuberculosis of the knee: a review of 10 cases. HABAXI, K.-K.; WANG, L.; MIAO, X.-G.; ALIMASI, WU Q.-K.; ZHAO, X.-B.; SU, J.-G.; YUAN, H. // European Review for Medical & Pharmacological Sciences;Dec2014, Vol. 18 Issue 23, p3587 

    OBJECTIVE: TO discuss the surgical methods of total knee arthroplasty (TKA) in the patients with active tuberculosis of the knee and find out its curative effect after TKA. PATIENTS ANDMETHODS: We analyzed 10 patients with active tuberculosis of the knee who received TKA in our department from...

  • Mid-term Results of Total Knee Arthroplasty Using PFC Sigma RP-F. Jun-Young Kim; Sang-Ho Cheon; Hee-Soo Kyung // Knee Surgery & Related Research;Dec2012, Vol. 24 Issue 4, p221 

    Purpose: We compared the mid-term results after total knee arthroplasty (TKA) using PFC Sigma RP-F mobile model with PFC Sigma PS fixed model. Materials and Methods: We analyzed 45 knees that underwent TKA with PFC Sigma RP-Fn (study group) and 45 knees with PFC Sigma PS (control group). The...

  • The femoral insertions of the anteromedial and posterolateral bundles of the anterior cruciate ligament: a radiographic evaluation. Steckel, Hanno; Musahl, Volker; Fu, Freddie H. // Knee Surgery, Sports Traumatology, Arthroscopy;Jan2010, Vol. 18 Issue 1, p52 

    The aim of this radiographic study was to visualize the femoral insertion sites of the anteromedial (AM) and posterolateral (PL) bundle of the anterior cruciate ligament (ACL) on lateral radiographs in different angles of knee flexion to gain better understanding for arthroscopic femoral tunnel...

  • The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty. Chen, Jerry; Yeo, Seng; Yew, Andy; Tay, Darren; Chia, Shi-Lu; Lo, Ngai; Chin, Pak // Knee Surgery, Sports Traumatology, Arthroscopy;Mar2014, Vol. 22 Issue 3, p630 

    Purpose: The aim of this study was to investigate the post-operative radiological outcomes of patient-specific instrumentation (PSI) surgery versus conventional total knee arthroplasty (TKA). Methods: Sixty patients scheduled for a primary TKA were prospectively divided into PSI or conventional...

  • Minimum Two-year Results of Revision Total Knee Arthroplasty Following Infectious or Non-infectious Causes. Kyoung-Jai Lee; Jae-Young Moon; Eun-Kyoo Song; Hong-An Lim; Jong-Keun Seon // Knee Surgery & Related Research;Dec2012, Vol. 24 Issue 4, p227 

    Purpose: To compare clinical outcome of revision total knee arthroplasty (TKA) between the infected and non-infected groups. Materials and Methods: This study compared the clinical and radiographic results of 21 infected and 15 non-infected revision TKAs at a minimum 2- years follow-up. Clinical...

  • Similar survival between screw cementless and cemented tibial components in young patients with osteoarthritis. Lizaur-Utrilla, Alejandro; Miralles-Muñoz, Francisco; Lopez-Prats, Fernando // Knee Surgery, Sports Traumatology, Arthroscopy;Jul2014, Vol. 22 Issue 7, p1585 

    Purpose: The aim of this study was to compare the outcomes of tibial fixation with either a cemented or cementless with screw augmentation component in young patients with non-inflammatory arthritis. Methods: Ninety-three patients aged 55 or younger with non-inflammatory arthritis were...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.