TITLE

Linear analysis of a W band groove-loaded folded waveguide traveling wave tube

AUTHOR(S)
He, Jun; Wei, Yanyu; Gong, Yubin; Wang, Wenxiang
PUB. DATE
November 2010
SOURCE
Physics of Plasmas;Nov2010, Vol. 17 Issue 11, p113305
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A linearized field theory of a groove-loaded folded waveguide traveling wave tube (FWTWT) is developed. The influence of groove dimensions and beam parameters on the linear gain and bandwidth of the device is investigated by numerical calculation. In addition, a comparison of the linear gain properties between the groove-loaded FWTWT and the conventional one is also carried out. It is indicated from the investigation that by the groove loading, the electric field that acts on the electron beam is enhanced, the electron beam gives more energy to wave, and the linear gain is raised.
ACCESSION #
55509448

 

Related Articles

  • Linear analysis of a rectangular waveguide cyclotron maser with a sheet electron beam. Zhao, Ding; Ding, Yaogen; Wang, Yong; Ruan, Cunjun // Physics of Plasmas;Nov2010, Vol. 17 Issue 11, p113110 

    A linear theory for a rectangular waveguide cyclotron maser with a sheet electron beam is developed by using the Laplace transformation approach. This theory can be applied to any TEmn rectangular waveguide mode. The corresponding equations for the TMmn mode in the rectangular waveguide are also...

  • Cerenkov and cyclotron Cerenkov instabilities in a dielectric loaded parallel plate waveguide sheet electron beam system. Zhao, Ding; Ding, Yaogen // Physics of Plasmas;Sep2011, Vol. 18 Issue 9, p093107 

    A dielectric loaded parallel plate waveguide sheet electron beam system can be taken as a reliable model for the practical dielectric loaded rectangular waveguide sheet beam system that has a transverse cross section with a large width to height ratio. By using kinetic theory, the dispersion...

  • Effect of symmetry center losses on energy bands and carrier kinematics in Zn3As2 and Cd3As2. Chuiko, G.; Don, N.; Martyniuk, V.; Stepanchikov, D. // Semiconductor Physics, Quantum Electronics & Optoelectronics;2006, Vol. 9 Issue 2, p17 

    The comparative analysis of the band structure and carrier kinematics for n-Cd3As2 and p-Zn3As2 has been executed. The influence of presence and absence of symmetry center in different crystalline phases of the above materials is explored. The direct and indirect solutions of dispersion...

  • A comparison between Rad-Hard Standard Float Zone (FZ) and Magnetic Czochralski (MCz) Silicon Diodes in Radiotherapy Electron Beams Dosimetry. dos Santos, T. C.; Gonçalves, J. A. C.; Vasques, M. M.; Tobias, C. C. B.; Neves-Junior, W. F. P.; Haddad, C. M. K.; Harkonen, J. // AIP Conference Proceedings;8/10/2011, Vol. 1351 Issue 1, p228 

    In this work we present the preliminary results obtained with a comparison between rad-hard FZ and MCz silicon diodes as on-line clinical electron beams dosimeters. The dynamic current response of the diodes under irradiation with electron beams within the energy range of 6 MeV up to 21 MeV was...

  • Dynamics of a high-current electron beam in an inverse high-power electron diode. Harper-Slaboszewicz, V. J.; Poukey, J. W.; Stygar, W. A.; Lee, J. R.; Fowler, W. E. // Journal of Applied Physics;11/1/1990, Vol. 68 Issue 9, p4481 

    Presents information on a study that examined the dynamics of a high-current electron beam in an inverse high-power electron diode. Description of an inverse triax diode; Results of the particle code simulations; Development of a model for the beam dynamics.

  • Aperture effects in intense beams. Bernal, S.; O’Shea, P. G.; Kishek, R.; Reiser, M. // AIP Conference Proceedings;2001, Vol. 569 Issue 1, p544 

    An aperture affects an intense beam in two ways: first, it changes the relative contributions of thermal and space charge effects by changing the ratio of emittance to generalized beam perveance; second, the velocity space is altered depending on the aperture size relative to the beam size and...

  • Adiabatic beam dynamics in a modified betatron. Roberts, G. A.; Rostoker, N. // Physics of Fluids (00319171);Jun85, Vol. 28 Issue 6, p1968 

    Electron beams in modified betatrons were previously analyzed by using a paraxial treatment. This treatment is valid only for a beam where particles have an axial velocity much larger than their perpendicular velocity. However, in accelerators such as the UCI Modified Betatron, the beam does not...

  • The effect of spot size on linearity improvement of tetra-lateral position sensitive detector. Cui, Song; Soh, Yeng // Optical & Quantum Electronics;Oct2011, Vol. 42 Issue 11-13, p721 

    Linearity improvement of tetra-lateral position sensitive detector (PSD) is highly desired in many applications where accurate measurements of the PSD are required. The effect of beam size on our newly proposed linearity improvement scheme is discussed in this paper. Theoretical studies on the...

  • RF design of X-band RF deflector for femtosecond diagnostics of LCLS electron beam. Dolgashev, Valery A.; Wang, Juwen // AIP Conference Proceedings;Dec2012, Vol. 1507 Issue 1, p682 

    We designed a successful constant impedance traveling wave X-band rf deflector for electron beam diagnostics at the 14 GeV SLAC Linac Coherent Light Source (LCLS). This is the first practical deflector built with a waveguide coupler. The 1-meter rf deflector produces 24 MeV peak transverse kick...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library