TITLE

A new real-time and precision capnography for human respiration carbon dioxide concentration

AUTHOR(S)
Jiachen Yang; Bin Wang; Ran Xu; Lei Wang
PUB. DATE
November 2010
SOURCE
Perfusion;Nov2010, Vol. 25 Issue 6, p399
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
This paper is a description of the designing of a new mainstream device to measure human respiration carbon dioxide concentration, based on non-dispersive infrared (NDIR) absorption technology. The device can be used to accurately monitor the cardiopulmonary status during anaesthesia and mechanical ventilation in real time. This new device can not only make up the error of real-time gas measurement of the side-stream device, but also make up the accuracy of the main-stream device. In the paper, four issues which can affect the measurement accuracy were considered: respiration gas flow, turbulence of the light source with all ranges of wavelength, temperature drift and signal noise. The experimental results showed that the device could produce a stable output signal and deviation of measurement accuracy could be achieved to within 4%.
ACCESSION #
55472893

 

Related Articles

  • Patients and Health Care Providers Breathe Easier with Capnography. Page, Christina Orlovsky // NurseZone Newsletter;6/17/2013, p1 

    The article focuses on the use of capnography tool in the operating room to monitor patient respiration while under anesthesia. It lists the innovative and proprietary technological benefits provided by Oridion Microstream Capnography from Covidien. The American Heart Association (AHA) adapted...

  • Capnography monitors.  // RN;Oct2002, Vol. 65 Issue 10, p65 

    Presents information on various brands of capnography monitors. Capnocheck Plus Capnograph from BCI; Microcap Portable Canograph from Oridion; NPB-70 Handheld Capnograph from Nellcor.

  • Efficient Ventilation Utilizing Noninvasive Capnography. Waugh, Jonathan B.; Epps, Chad A. // AARC Times;Mar2009, Vol. 33 Issue 3, p12 

    The article discusses the advantages of using noninvasive capnography in monitoring the ventilatory status of patients. Compared to a transcutaneous carbon dioxide (tcCO2) monitor, which approximates arterial CO2 detected through the skin, capnography approximates arterial CO2 by directly...

  • Adjustable Monitor Can Be Tailored To Patients' Needs.  // RN;Feb2004, Vol. 67 Issue 2, p72 

    Features the sidestream capnography option in BCI Inc.'s Advisor portable vital signs monitor. Application in the measurement and analysis of inspired and end-tidal carbon dioxide; Other parameters measured by the device.

  • Spacelabs Healthcare Receives 510(k) Clearance for Sidestream Capnography Module.  // Biomedical Market Newsletter;8/28/2012, Vol. 21, p1 

    The article informs that Spacelabs Healthcare Inc. has received clearance from the U.S. Food & Drug Administration (FDA) for its Capnography Pod. It informs that the Capnography Pod provides a non-invasive method ofmeasuring the concentration of carbon dioxide in a gas mixture and helps in the...

  • Evaluation of an Oxygen Mask-Based Capnometry Device in Subjects Extubated After Abdominal Surgery. Shunsuke Takaki; Takahiro Mihara; Kenji Mizutani; Osamu Yamaguchi; Takahisa Goto // Respiratory Care;May2015, Vol. 60 Issue 5, p705 

    BACKGROUND: For early detection of respiratory and hemodynamic changes during anesthesia, continuous end-tidal carbon dioxide concentration (PETCO2) is monitored by capnometry. However, the accuracy of CO2 monitoring during spontaneous breathing in extubated patients remains undetermined....

  • Update 2003.  // Critical Care Nurse;Aug2003, Vol. 23 Issue 4, p88 

    Presents an update on the techniques of carbon dioxide measurement in critical care. Use of exhaled carbon dioxide measurement during placement of feeding tubes; Use of resuscitation bags in carbon dioxide measurement.

  • Volumetric capnography as a bedside monitoring of thrombolysis in major pulmonary embolism. Verschuren, Franck; Heinonen, Erkki; Clause, Didier; Roeseler, Jean; Thys, Frédéric; Meert, Philippe; Marion, Eric; El Gariani, Abduiwahed; Col, Jacques; Reynaert, Marc; Liistro, Giuseppe; Thys, Frédéric; El Gariani, Abdulwahed // Intensive Care Medicine;Nov2004, Vol. 30 Issue 11, p2129 

    Objective: To describe the use of volumetric capnography, a plot of expired CO(2) concentration against expired volume, in monitoring fibrinolytic treatment of major pulmonary embolism.Design and Setting: Two case reports in the emergency department of a teaching...

  • QUANTIFYING ORGANICS THROUGH OXIDATION, DETECTION. DePalma, Angelo // Lab Manager Magazine;Jan2011, Vol. 6 Issue 1, p38 