ABSTRACT
Plasma electrolyte oxidation (PEO) was utilized to produce thick films on titanium and Ti-5Mo-4V-3Al alloys by immersing them in various solutions of NaSiO and KOH with different concentrations to investigate the effect of SiO/OH relations on the morphology and formed phases by utilizing SEM and XRD. Corrosion resistance is evaluated by open circuit potential (OCP) variation of samples in NaCl 3.5% and potentiodynamic polarization. The results show that the unstable film is formed by using more aggressive PEO electrolyte. By increasing this ratio, pore size varied from fine to coarse and the rate of corrosion decreased and OCP became more positive. The best protective film was formed in SiO/OH ratio of 1.
ACCESSION #
55266951

 

Related Articles

  • Osseointegration improvement by plasma electrolytic oxidation of modified titanium alloys surfaces. Echeverry-Rendón, Mónica; Galvis, Oscar; Quintero Giraldo, David; Pavón, Juan; López-Lacomba, José; Jiménez-Piqué, Emilio; Anglada, Marc; Robledo, Sara; Castaño, Juan; Echeverría, Félix // Journal of Materials Science: Materials in Medicine;Feb2015, Vol. 26 Issue 2, p1 

    Titanium (Ti) is a material frequently used in orthopedic applications, due to its good mechanical properties and high corrosion resistance. However, formation of a non-adherent fibrous tissue between material and bone drastically could affect the osseointegration process and, therefore, the...

  • A microstructural study of the structure of plasma electrolytically oxidized titanium foils. El Achhab, Mhamed; Erbe, Andreas; Koschek, Georg; Hamouich, Rachid; Schierbaum, Klaus // Applied Physics A: Materials Science & Processing;Sep2014, Vol. 116 Issue 4, p2039 

    The structure and distribution of TiO rutile and anatase phases of anodized titanium foil, subjected to a special high-voltage electrochemical preparation technique, are reported. We applied X-ray diffraction, scanning electron microscopy, energy-dispersive X-ray spectroscopy, Raman...

  • Preparation and bioactivity of embedded-style hydroxyapatite-titania nanotube arrays. XIAO, X.-F.; LIU, R.-F.; TIAN, T. // Materials Science (0137-1339);2009, Vol. 27 Issue 1, p23 

    Embedded-style hydroxyapatite-titania nanotube arrays were successfully prepared by anodic oxidation of titanium substrate and centrifugal filling hydroxyapatite precursor sol into hollow nanotubes. The morphology, microstructure and thermal stability of the samples were characterized by X-ray...

  • Preparation and photocatalytic activity of N-doped TiO nanotube array films. Dang, Mingming; Zhou, Yi; Li, Hong; Lv, Caixia // Journal of Materials Science: Materials in Electronics;Jan2012, Vol. 23 Issue 1, p320 

    The N-doped TiO nanotube array films were fabricated directly by one-step electrochemical anodic oxidation of Ti foils in an HF electrolyte containing ammonium and nitrate ions. The as-prepared samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy...

  • Electrochemical Properties of Joints Formed Between Sn-9Zn-1.5Ag-1Bi Alloys and Cu Substrates in a 3.5 wt.% NaCl Solution. Chih-Yao Liu; Ying-Ru Chen; Wang-Long Li; Min-Hsiung Hon; Moo-Chin Wang // Journal of Electronic Materials;Nov2007, Vol. 36 Issue 11, p1531 

    The electrochemical properties of the joints formed between Sn-9Zn-1.5Ag-1Bi alloys and Cu substrates in a 3.5 wt.% NaCl solution have been investigated by potentiodynamic polarization, X-ray diffraction, and scanning electron microscopy. For the Sn-9Zn-1.5Ag-1Bi/Cu joints in a 3.5 wt.% NaCl...

  • Influence of Pd Addition of CoCrMo Biomedical Alloys on the Microhardness Behaviour. SAHIN, O.; UZUNOGLU, S.; SAHIN, E. // Acta Physica Polonica, A.;Aug2015, Vol. 128 Issue 2B, pB-145 

    CoCrMo alloys are often used as the material for metal artificial joint because of their high corrosion resistance and mechanical properties. In this study CoCrMo alloys having different palladium amount of produced by investment casting method. Scanning electron microscopy, X-ray diffraction...

  • A Novel Biodegradable Phosphate Coating on AZ31B Alloy. Tingting Yan; Siyu Wu; Qinghua Chen; Qingmei Liu; Jiarong Yang // Applied Mechanics & Materials;2014, Vol. 707, p158 

    Mg and its alloys draw more and more attentions to be used as biodegradable medical materials. But the rapid degradation of those materials limits their clinical applications. In this article, a phosphate coating was prepared on AZ31B magnesium alloy to improve its anti-corrosion property....

  • Plasma Electrolytic Oxidation of Binary Al-Sn Alloys. GENCER, Y.; TARAKCI, M.; GULEC, A. E.; OTER, Z. CAGATAY // Acta Physica Polonica, A.;Feb2014, Vol. 125 Issue 2, p659 

    Binary Al-Sn (1, 2, 4, 6, 8 at.% Sn) synthetic alloys were prepared under vacuum-atmosphere controlled furnace. The Al-Sn alloys were coated by plasma electrolytic oxidation technique for 120 min in aqueous electrolyte containing sodium silicate and potassium hydroxide using the same electrical...

  • New Functional Materials Based on Nano- and Micro-Objects with Developed Surface. DOROGOV, M. V.; DOVZHENKO, O. A.; GRYZUNOVA, N. N.; VIKARCHUK, A. A.; ROMANOV, A. E. // Acta Physica Polonica, A.;2015, Vol. 128 Issue 4, p503 