TITLE

Dose verification of helical tomotherapy intensity modulated radiation therapy planning using 2D-array ion chambers

AUTHOR(S)
Xu, S.; Xie, C.; Ju, Z.; Dai, X.; Gong, H.; Wang, L.; Yang, J.
PUB. DATE
March 2010
SOURCE
Biomedical Imaging & Intervention Journal;Mar2010, Vol. 6 Issue 1, p1
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Purpose: To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered for the patients during treatments. Materials and Methods: A pixel-segmented ionisation chamber device, IMRT MatriXX™ and Multicube™ phantom from IBA were used on ten selected Tomotherapy IMRT/IGRT head and neck plans in this study. The combined phantom was set up to measure the dose distribution from coronal and sagittal planes. The setup of phantom was guided for verifying the correction position by pre-treatment Tomotherapy MVCT images. After the irradiation, the measured dose distributions of coronal and sagittal planes were compared with those from calculation by the planning system for cross verification. The results were evaluated by the absolute and relative doses as well as Gamma (γ) function. The feasibility of the different measuring methods was studied for this rotational treatment technique. Results: The dose distributions measured by the MatriXX 2D array were in good agreements with plans calculated by Tomotherapy planning system. The discrepancy between the measured dose and predicted dose in the selected points was within ±3%. In the comparison of the pixel-segmented ionisation chamber versus treatment planning system using the 3 mm/3% γ-function criteria, the mean passing rates of 2 mm dose grid with γ-parameter =1 were 97.37% and 96.91%, in two orthogonal planes (coronal and sagittal directions), respectively. Conclusion: MatriXX with Multicube is a new system created for rotational delivery quality assurance (QA) and found to be reliable to measure both absolute dose and relative dose distributions, simultaneously. It achieves the goal of an efficient and accurate dosimetry validation method of the helical delivery pattern for the Helical Tomotherapy IMRT planning.
ACCESSION #
54904391

 

Related Articles

  • A Survey on the Quality Assurance Procedures Used in Intensity Modulated Radiation Therapy (IMRT) at Indian Hospitals. Kumar, Rajesh; Sharma, S. D.; Amols, H. I.; Mayya, Y. S.; Kushwaha, H. S. // Journal of Cancer Science & Therapy;Nov2010, Vol. 2 Issue 6, p166 

    A national survey to obtain information about the Quality Assurance (QA) procedures and methods being followed at Indian radiotherapy centers for intensity modulated radiation therapy (IMRT) was conducted. A questionnaire containing parameters relevant to IMRT QA was evolved to collect the...

  • Optimized point dose measurement: An effective tool for QA in intensity-modulated radiotherapy. Kumar, Alok; Mukherjee, Gautam; Yadav, Girigesh; Pandey, Vinod; Bhattacharya, Kalyan // Journal of Medical Physics;Oct2007, Vol. 32 Issue 4, p156 

    In some cases of Intensity-modulated radiotherapy (IMRT) point dose measurement, there exists significant deviation between calculated and measured dose at isocenter, sometimes greater than ±3%. This may be because IMRT fields generate complex profiles at the reference point. The deviation...

  • Impact of very long time output variation in the treatment of total marrow irradiation with helical tomotherapy. Takahashi, Yutaka; Hui, Susanta K. // Radiation Oncology;2013, Vol. 8 Issue 1, p1 

    Background: Beam-on time in Total Marrow Irradiation (TMI) delivery with helical tomotherapy is more than 30 minutes. The purpose of this study was to investigate extended time output variation in tomotherapy machine without dose servo system and its impact on the dosimetry of TMI planning....

  • Experimental Validation of Treatment Planning for Multiple Radiotherapy Fields by EDR2 Film Dosimeter. Fayaz, Vahid; Tavakol, Asieh // World Academy of Science, Engineering & Technology;Aug2011, Issue 56, p623 

    To investigate the applicability of the EDR-2 film for clinical radiation dosimetry, percentage depth-doses, profiles and distributions in open and dynamically wedged fields were measured using film and compared with data from a Treatment Planning system.The validity of the EDR2 film to measure...

  • Skin Dose Estimation from 6MV Photon Beams for Different Clinical Setup Parameters. Fayaz, Vahid; Zandi, Hassan; Tavakol, Asieh // World Academy of Science, Engineering & Technology;Aug2011, Issue 56, p629 

    Estimation of surface dose is very important for patients undergoing radiation therapy. Several instruments have been used to measure absorbed radiation dose under non-electronic equilibrium conditions, such as in the build-up region or near the interface between two different media, including...

  • Dosimetric Verification and Validation of Conformal and IMRT Treatments Fields with an Ionization Chamber 2D-Array. Evangelina, Figueroa M.; Gabriel, Reséndiz G.; Miguel, Pérez P. // AIP Conference Proceedings;8/11/2008, Vol. 1032 Issue 1, p222 

    A three-dimensional treatment planning system requires comparisons of calculated and measured dose distributions. It is necessary to confirm by means of patient specific QA that the dose distributions are correctly calculated, and that the patient data is correctly transferred to and delivered...

  • A national dosimetry audit of intraoperative radiotherapy. EATON, D. J.; EARNER, B.; FAULKNER, P.; DANCER, N. // British Journal of Radiology;Dec2013, Vol. 86 Issue 1032, p1 

    Objective: National dosimetry audits are a fundamental part of quality assurance in radiotherapy, especially for new techniques. Intraoperative radiotherapy with a compact mobile kilovoltage X-ray source is a novel approach for the treatment of breast and other cancers. All seven current...

  • Dosimetry: The Art of Measuring the Energy Deposited by Ionizing Radiation in a Medium. Brandan, María-Ester // AIP Conference Proceedings;11/26/2007, Vol. 958 Issue 1, p153 

    We present a brief overview of ideas related to dosimetry, its principles, and its practice. Cavity theories and the need for careful interpretation of dosimetric measurements are introduced. Ionization chambers, TLDs and radiochromic films are described, as well as the accuracy requirements for...

  • Dosimetric comparison between jaw tracking and static jaw techniques in intensity-modulated radiotherapy. Zhongsu Feng; Hao Wu; Yibao Zhang; Yunjun Zhang; Jinsheng Cheng; Xu Su // Radiation Oncology;2015, Vol. 10 Issue 1, p396 

    Purpose To compare the dosimetric differences between jaw tracking technique (JTT) and static jaw technique (SJT) in dynamic intensity-modulated radiotherapy (d-IMRT) and assess the potential advantages of jaw tracking technique. Methods Two techniques, jaw tracking and static jaw, were used...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics