The x-ray imaging crystal spectrometer (XICS) for the Korea Superconducting Tokamak Advanced Research has been first applied for the experimental campaign in 2009. The XICS was designed to provide measurements of the profiles of the ion and electron temperatures from the heliumlike argon (Ar XVII) spectra. The basic functions of the XICS are properly working although some satellites lines are not well matched with the expected theoretical values. The initial experimental results from the XICS are briefly described.


Related Articles

  • Upgrade of the Glasgow photon tagging spectrometer for Mainz MAMI-C. McGeorge, J. C.; Kellie, J. D.; Annand, J. R. M.; Ahrens, J.; Anthony, I.; Clarkson, A.; Hamilton, D. J.; Lumsden, P. S.; McNicoll, E. F.; Owens, R. O.; Rosner, G.; Thomas, A. // European Physical Journal A -- Hadrons & Nuclei;Jul2008, Vol. 37 Issue 1, p129 

    The Glasgow photon tagging spectrometer at Mainz has been upgraded so that it can be used with the 1500MeV electron beam now available from the Mainz microtron MAMI-C. The changes made and the resulting properties of the spectrometer are discussed.

  • Recording the energy spectrum and time characteristics of laser-plasma electrons. Bessarab, A. V.; Gorbunov, A. A.; Martsovenko, D. I.; Starodubtsev, V. A.; Sungatullin, R. R. // Instruments & Experimental Techniques;Mar2010, Vol. 53 Issue 2, p258 

    The design of small spectrometers of laser-plasma electrons with energies in the range 1�1000 keV is described. A technique for calibrating spectrometers is presented. The results of measuring an electron spectrum in a laser experiment performed with these spectrometers are presented.

  • Multipurpose Compact Spectrometric Unit. Bočarov, Viktor; Čermák, Pavel; Mamedov, Fadahat; Štekl, Ivan // AIP Conference Proceedings;11/9/2009, Vol. 1180 Issue 1, p117 

    A new standalone compact spectrometer was developed. The device consists of analog (peamplifier, amplifier) and digital parts. The digital part is based on the 160 MIPS Digital Signal Processor. It contains 20 Msps Flash-ADC, 1 MB RAM for spectra storage, 128 KB Flash/ROM for firmware storage,...

  • An integrated charge exchange recombination spectroscopy/beam emission spectroscopy diagnostic for Alcator C-Mod tokamak. Bespamyatnov, I. O.; Rowan, W. L.; Liao, K. T.; Granetz, R. S. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D709 

    A novel integrated charge exchange recombination spectroscopy (CXRS)/beam emission spectroscopy (BES) system is proposed for C-Mod, in which both measurements are taken from a shared viewing geometry. The supplementary BES system serves to quantify local beam densities and supplants the common...

  • Mass spectrometer.  // LC-GC North America;Dec2005, Vol. 23 Issue 12, p1298 

    The article evaluates the Finnigan LXQ linear ion-trap mass spectrometer by Thermo Electron Corp. and offers information on its ion-trap features and its applications in drug discovery and proteomics.

  • Ionization of Nitrogen, Oxygen, Water, and Carbon Dioxide Molecules by Near-Threshold Electron Impact. Zavilopulo, A. N.; Chipev, F. F.; Shpenik, O. B. // Technical Physics;Apr2005, Vol. 50 Issue 4, p402 

    An experimental technique for measuring the cross sections of direct and dissociative ionization of N2 ,O2 ,H2O, and CO2 molecules by electron impact in the near-threshold energy range is described. The setup used in the experiments allows mass separation of ions with a monopole mass...

  • e-beam-referenced work-function evaluation in an x-ray photoelectron spectrometer. Cohen, H.; Nogues, C.; Zon, I.; Lubomirsky, I. // Journal of Applied Physics;6/1/2005, Vol. 97 Issue 11, p113701 

    A method for work-function evaluation is proposed, based on recording the shift of x-ray photoelectron signals from a surface irradiated by low-energy electrons. The method is capable of measuring samples with very low conductivity, poor back contacts, and high dielectric constants. The method...

  • KATRIN – Direct measurement of ν-masses in the sub-eV range. Drexlin, Guido // European Physical Journal C -- Particles & Fields;Mar2004 Supplement 1, Vol. 33, ps808 

    The rlsruhe tium eutrino (KATRIN) experiment is a next-generation direct neutrino mass experiment with sensitivity to sub-eV ν-masses. It combines an ultra-luminous molecular windowless gaseous tritium source with a high resolution electrostatic retarding spectrometer (MAC-E filter) to...

  • Studying of hypernuclei with nuclotron beams. Averyanov, A. V.; Avramenko, S. A.; Aksinenko, V. D.; Anikina, M. Kh.; Bazylev, S. N.; Balandin, V. P.; Batusov, Yu. A.; Belikov, Yu. A.; Borzunov, Yu. T.; Borodina, O. V.; Golokhvastov, A. I.; Golovanov, L. B.; Granja, C.; Ivanov, A. B.; Ivanov, Yu. L.; Isupov, A. Yu.; Kohout, Z.; Korotkova, A. M.; Litvinenko, A. G.; Lukstiņš, J. // Physics of Atomic Nuclei;Dec2008, Vol. 71 Issue 12, p2101 

    A spectrometer is created to study relativistic hypernuclei produced with beams of accelerated nuclei from the Nuclotron facility (Dubna, JINR). Test runs have been carried out and the conclusion is drawn that the properties of the facility meet the requirements of the task of searching for...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics