TITLE

Synchronization of Thomson scattering measurements on MAST using an FPGA based 'Smart' trigger unit

AUTHOR(S)
Naylor, G.
PUB. DATE
October 2010
SOURCE
Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10E110
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The MAST Thomson scattering diagnostic has recently been upgraded to make electron density and temperature measurements at 130 points across the 1.5 m diameter of the plasma. The new system is able to take 240 measurements per second using eight Nd:YAG lasers, each running at 30 Hz. The exact firing time of these lasers is adjusted with 100 ns precision using a field programmable gate array based trigger unit. Trigger pulses are produced to fire the lamps of all lasers and the Q switches with the appropriate delay depending on the warm-up status. The lasers may be fired in rapid bursts so as to achieve a high temporal resolution over eight points separated down to the microsecond level. This trigger unit receives optical trigger events and signals from external sources, allowing the trigger sequences to be resynchronized to the start of the plasma pulse and further events during the shot such as the entry of a fuelling pellet or randomly occurring plasma events. This resynchronization of the laser firing sequence allows accurate and reproducible measurements of fast plasma phenomena.
ACCESSION #
54858181

 

Related Articles

  • Design and implementation of a full profile sub-cm ruby laser based Thomson scattering system for MAST. O'Gorman, T.; Mc Carthy, P. J.; Prunty, S.; Walsh, M. J.; Dunstan, M. R.; Huxford, R. B.; Naylor, G.; Maguet, Emmanuel; Scannell, R.; Shibaev, S. // Review of Scientific Instruments;Dec2010, Vol. 81 Issue 12, p123508 

    A major upgrade to the ruby Thomson scattering (TS) system has been designed and implemented on the Mega-ampere spherical tokamak (MAST). MAST is equipped with two TS systems, a Nd:YAG laser system and a ruby laser system. Apart from common collection optics each system provides independent...

  • Laser system for high resolution Thomson scattering diagnostics on the COMPASS tokamak. Bohm, P.; Sestak, D.; Bilkova, P.; Aftanas, M.; Weinzettl, V.; Hron, M.; Panek, R.; Baillon, L.; Dunstan, M. R.; Naylor, G.; Walsh, M. J. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D511 

    A new Thomson scattering diagnostic has been designed and is currently being installed on the COMPASS tokamak in IPP Prague in the Czech Republic. The requirements for this system are very stringent with approximately 3 mm spatial resolution at the plasma edge. A critical part of this diagnostic...

  • Dynamic laser alignment control for Thomson scattering on ASDEX Upgrade. Murmann, H.; Jakobi, M.; Kurzan, B.; Schilling, H.B. // Review of Scientific Instruments;Oct2003, Vol. 74 Issue 10, p4310 

    Thomson scattering, as a very direct diagnostic method to measure electron density n[sub e] and temperature T[sub e] of a plasma, has become a standard tool in plasma physics. Reliable Nd:YAG lasers have been developed for industrial applications, the accuracy of scattering measurements is...

  • Upgraded multipulse laser and multipoint Thomson scattering diagnostics on EAST. Zang, Qing; Zhao, Junyu; Yang, Li; Hu, Qingsheng; Xi, Xiaoqi; Dai, Xingxing; Yang, Jianhua; Han, Xiaofeng; Li, Mengting; Hsieh, C. L. // Review of Scientific Instruments;Jun2011, Vol. 82 Issue 6, p063502 

    Recently a new Thomson scattering diagnostic system was upgraded in EAST tokamak experiment using a multipulse Nd:YAG (neodymium-yttrium aluminium garnet) laser and a multipoint observation volumes. This diagnostic uses a new optical laser alignment technique that was made to determine...

  • Development of KSTAR Thomson scattering system. Lee, J. H.; Oh, S. T.; Wi, H. M. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D528 

    To measure the electron temperature (Te) and electron density (ne) profiles in the Korean Superconducting Tokamak Advanced Research (KSTAR) device for the KSTAR third campaign (September 2010), we designed and installed a Thomson scattering system. The KSTAR Thomson scattering system is designed...

  • Comparing optical Thomson scattering with emission spectroscopy in He plasmas induced by laser breakdown at 1 atmosphere. Nedanovska, E; Riley, D.; Lewis, C. L. S; Morgan, T.; Hüwel, L.; Nersisyan, G.; Graham, W. G. // AIP Conference Proceedings;5/25/2012, Vol. 1438 Issue 1, p29 

    We have carried out optical Thomson scattering measurements from a laser induced breakdown in He at 1 atmosphere. The breakdown was created with a Nd:YAG laser with 9ns pulse duration and 400mJ pulse energy focused into a chamber filled with He. A second harmonic Nd:YAG laser with 9ns pulses and...

  • The effect of laser wavelength on heating of ablated carbon plume. Hoffman, J.; Moscicki, T.; Szymanski, Z. // Applied Physics A: Materials Science & Processing;Sep2011, Vol. 104 Issue 3, p815 

    The effect of laser wavelength on heating of the ablated carbon plume is studied. The plasma absorption coefficients are calculated in order to analyze the results and an experiment is conducted using the first, second, and third harmonic of a Nd:YAG laser. Plasma temperature and electron...

  • Forward plasma emission through laser-foil interaction with nanosecond lasers. Horisawa, Hideyuki; Yamaguchi, Shigeru; Funaki, Ikkoh // Applied Physics A: Materials Science & Processing;Sep2011, Vol. 104 Issue 3, p935 

    Fundamental investigations of plasma diagnostics of a forward laser plasma acceleration employing laser-foil interactions were conducted for an Al-foil target irradiated with an Nd:YAG laser of 1 J/pulse with pulse width of 10 ns. Temporal evolutions of electron temperatures and densities were...

  • Thomson scattering with a gated intensified charge-coupled device camera using a frequency... Hirsch, K.; Volk, G. // Review of Scientific Instruments;Nov95, Vol. 66 Issue 11, p5369 

    Reports on Thomson scattering with a gated intensified charge-coupled device camera using a frequency doubled periodically pulsed Neodymium:YAG laser. Use of only one detector array for spatial and spectral profile measurements in repetitive operation, easing alignment, and calibration;...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics