TITLE

Study on the effect of measuring methods on incident photon-to-electron conversion efficiency of dye-sensitized solar cells by home-made setup

AUTHOR(S)
Guo, Xiao-Zhi; Luo, Yan-Hong; Zhang, Yi-Duo; Huang, Xiao-Chun; Li, Dong-Mei; Meng, Qing-Bo
PUB. DATE
October 2010
SOURCE
Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p103106
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
An experimental setup is built for the measurement of monochromatic incident photon-to-electron conversion efficiency (IPCE) of solar cells. With this setup, three kinds of IPCE measuring methods as well as the convenient switching between them are achieved. The setup can also measure the response time and waveform of the short-circuit current of solar cell. Using this setup, IPCE results of dye-sensitized solar cells (DSCs) are determined and compared under different illumination conditions with each method. It is found that the IPCE values measured by AC method involving the lock-in technique are sincerely influenced by modulation frequency and bias illumination. Measurements of the response time and waveform of short-circuit current have revealed that this effect can be explained by the slow response of DSCs. To get accurate IPCE values by this method, the measurement should be carried out with a low modulation frequency and under bias illumination. The IPCE values measured by DC method under the bias light illumination will be disturbed since the short-circuit current increased with time continuously due to the temperature rise of DSC. Therefore, temperature control of DSC is considered necessary for IPCE measurement especially in DC method with bias light illumination. Additionally, high bias light intensity (>2 sun) is found to decrease the IPCE values due to the ion transport limitation of the electrolyte.
ACCESSION #
54858092

 

Related Articles

  • Measuring methods of cell performance of dye-sensitized solar cells. Koide, Naoki; Han, Liyuan // Review of Scientific Instruments;Sep2004, Vol. 75 Issue 9, p2828 

    Cell performance measuring methods for dye-sensitized solar cells (DSCs) were investigated in comparison with those of crystalline silicon solar cells. It was found that cell performances of DSCs varied according to voltage sweep direction and sampling delay time. On the other hand, this...

  • Electron temperature determination and subsequent analysis of short time-scale variation of plasma parameters in ISTTOK discharges. Plyusnin, V. V.; Cabral, J. A. C.; Figueiredo, H.; Varandas, C. A. F. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1807 

    Measurements of the electron temperature using standard diagnostics, like electron cyclotron emission or soft x-ray diagnostics, tend to be inadequate due to the natural limitations of these methods at low-toroidal magnetic field (B[sub 0] ≤ 0.5 T) and plasma density [ n[sub e] ∼...

  • Design and noise model for CCD-based, time-resolved PHA measurements. Schooff, R.; Diem, S.; Fonck, R.; Reinke, M.; Tritz, K. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p2007 

    A CCD pulse height analysis system is considered for the measurement of electron temperature on the Pegasus Toroidal Experiment. The first-generation CCD/PHA system will have one spatial point and obtain seven time points with a time resolution of 2.4 ms. Time resolution is achieved by shifting...

  • Thomson scattering upgrades on Alcator C-Mod. Hughes, J. W.; Mossessian, D.; Zhurovich, K.; DeMaria, M.; Jensen, K.; Hubbard, A. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1667 

    The Thomson scattering (TS) diagnostics set has been upgraded to deliver measurements of electron temperature (T[sub e]) and density (n[sub e]) with improved temporal and spatial resolution. Two 30 Hz, 1.3 J Nd-doped yttrium-aluminum-garnet (Nd:YAG) lasers share a vertical beam path through the...

  • A selection method to improve temperature compensation of current regulator. Lin, Yan-Fang // Review of Scientific Instruments;Jun2000, Vol. 71 Issue 6 

    A selection method to improve temperature compensation is proposed, which is effective in forming current regulator device with low temperature coefficient. The experimental results show that the temperature coefficients are of the order of 10[sup -5]/°C. The method is simple and the device...

  • Camera length and field of view in Makyoh-topography instruments. Riesz, Ferenc // Review of Scientific Instruments;Feb2001, Vol. 72 Issue 2, p1591 

    Makyoh topography is an optical method for the study of the large-scale morphology of mirror-like surfaces. Formulas are derived for the two basic parameters, the camera length and the field of view of Makyoh instruments. The relation between these parameters and the sensitivity are established....

  • Diamond anvil cell for cryogenic temperature with optical measurement system. Kawamura, Haruki; Tachikawa, Kyoji; Shimomura, Osamu // Review of Scientific Instruments;Oct85, Vol. 56 Issue 10, p1903 

    A diamond anvil type high-pressure cell for a low-temperature experiment with an optical system is described. The diamond anvil type pressure cell is actuated by helium gas in the cryostat at low temperatures. The optical system is for the pressure calibration at low temperatures by the use of...

  • The beam position monitor of the BEAR beamline. Giglia, Angelo; Mahne, Nicola; Pedio, Maddalena; Nannarone, Stefano; Pelizzo, Maria Guglielmina; Naletto, Giampiero; Zambolin, Paolo // Review of Scientific Instruments;Jun2005, Vol. 76 Issue 6, p063111 

    This article describes the photon beam position monitor installed at the BEAR beamline at Elettra, Trieste. The device, based on four Mo photoemitting plates, is installed upstream of the beamline optics. Two modes of operation are possible, including single-plate operation (integral mode) and...

  • Recent design upgrades of the APS beamline standard components. Shu, Deming; Ramanathan, Mohan; Haeffner, Dean R. // Review of Scientific Instruments;Mar2002, Vol. 73 Issue 3, p1584 

    Over the last five years, based on the operating experiences, many upgrades have been made to the beamline standard components to continue improving beamline performance and reliability at the Advanced Photon Source (APS). In this article, the particular design upgrades, as well as the new...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library