TITLE

Construction and testing of the instrument for neutron holographic study at the Budapest Research Reactor

AUTHOR(S)
Markó, Márton; Szakál, Alex; Török, Gyula; Cser, László
PUB. DATE
October 2010
SOURCE
Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p105110
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Neutron scattering device dedicated to neutron holography experiments is described. The device is operating at a constant wavelength prepared by a double focusing monochromator. It is equipped by highly efficient shielding, proper collimator, Eulerian cradle, monitor detector, gamma-ray, and neutron detectors as well. Relevant software serves as control for the measurement and data collection. The harmonized application of the components enumerated above makes our device extremely efficient and unparalleled. Two atomic resolution neutron holographic experiments carried out illustrate the efficiency and power of the instrument.
ACCESSION #
54858066

 

Related Articles

  • High-energy-resolution x-ray optics with refractive collimators. Chumakov, A. I.; Ru¨ffer, R.; Leupold, O.; Barla, A.; Thiess, H.; Asthalter, T.; Doyle, B. P.; Snigirev, A.; Baron, A. Q. R. // Applied Physics Letters;7/3/2000, Vol. 77 Issue 1 

    We have tested the concept of a high-resolution x-ray monochromator with a refractive collimator as an optical element. Two options were examined, where the refractive collimator was included either instead of, or in addition to the first crystal of the high-resolution monochromator. The first...

  • Magnetic phase transitions in CsCoBr3. Farkas, A.; Gaulin, B. D.; Tun, Z.; Briat, B. // Journal of Applied Physics;4/15/1991, Vol. 69 Issue 8, p6167 

    Provides information on elastic neutron-scattering measurements on a cesium-cobalt-bromine antiferromagnet. Presence of a third ordered phase at intermediate temperatures; Use of tight collimation of both the incident beam and the scattered beam; Reason for the change in the relative intensity...

  • Resolution of three-axis spectrometers by phase-space methods. Cussen, L.D. // Applied Physics A: Materials Science & Processing;Dec2002 Supplement, Vol. 74 Issue 6, ps58 

    Phase-space arguments are used to discuss the transmission function of three-axis spectrometers using an approximation where beam elements have rectangular rather than Gaussian transmission profiles. The optimum choice of collimators and monochromators and the 'focussing angle in scattering' are...

  • The use of multichannel collimation in small-angle neutron scattering: a computer-simulation study. Falcão, A.N.; Margaça, F.M.A.; Carvalho, F.G. // Applied Physics A: Materials Science & Processing;Dec2002 Supplement, Vol. 74 Issue 6, ps1462 

    A Monte Carlo computer simulation was performed to evaluate the use of converging multichannel collimation in a small-angle neutron-scattering arrangement, giving guidelines for the construction of a first prototype. The neutron-absorbing efficiency as well as the divergence of the incoming beam...

  • A novel compact three-dimensional laser-sintered collimator for neutron scattering. Ridley, Christopher J.; Manuel, Pascal; Khalyavin, Dmitry; Kirichek, Oleg; Kamenev, Konstantin V. // Review of Scientific Instruments;Sep2015, Vol. 86 Issue 9, p1 

    Improvements in the available flux at neutron sources are making it increasingly feasible to obtain refineable neutron diffraction data from samples smaller than 1 mm³. The signal is typically too weak to introduce any further sample environment in the 30-50 mm diameter surrounding the sample...

  • A water-cooled compound refractive lens as a white beam collimator. Zhao, J. Y.; Alp, E. E.; Toellner, T. S.; Sturhahn, W.; Sinn, H.; Shu, D. // Review of Scientific Instruments;Mar2002, Vol. 73 Issue 3, p1611 

    A white beam collimator has been built to increase the efficiency of a diamond high-heat-load premonochromator. The collimator is composed of a water-cooled beryllium compound refractive lens. We demonstrate a 30% increase in spectral flux of the diamond premonochromator (at 22.6 keV) by using...

  • Beamline X-11A at the NSLS: A unique facility for x-ray absorption spectroscopy. Heald, S. M.; Sayers, D. E. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p1932 

    The design and operation of beamline X-11A at the NSLS is described. It employs a unique optical design using a two/four crystal monochromator and a SiC collimating mirror. In either the two- or four-crystal mode a sagittal focusing crystal allows collection of up to 5 mrad of horizontal...

  • Double-Focusing Thermal Triple-Axis Spectrometer at the NCNR. Lynn, J. W.; Chen, Y.; Chang, S.; Zhao, Y.; Chi, S.; Ratcliff II, W.; Ueland, B. G.; Erwin, R. W. // Journal of Research of the National Institute of Standards & Tec;2012, Vol. 117 Issue 1, p61 

    The new thermal triple-axis spectrometer at the NIST Center for Neutron Research (NCNR) is located at the BT-7 beam port. The 165 mm diameter reactor beam is equipped with a selection of Söller collimators, beam-limiters, and a pyrolytic graphite (PG) filter to tailor the beam for the dual...

  • Characteristics of Pyrolytic Graphite as a Neutron Monochromator. Adib, M.; Habib, N.; El-Mesiry, M. S.; Fathallah, M. // Energy & Environment Research;Jun2012, Vol. 2 Issue 1, p35 

    Pyrolytic graphite (PG) has become nearly indispensable in neutron spectroscopy. Since the integrated reflectivity of the monochromatic neutrons from PG crystals cut along its c-axis is high within a wavelength band from 0.1 nm up to 0.65 nm. The monochromatic features of PG crystal is detailed...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics