TITLE

A digital method for separation and reconstruction of pile-up events in germanium detectors

AUTHOR(S)
Nakhostin, M.; Podolyak, Zs.; Regan, P. H.; Walker, P. M.
PUB. DATE
October 2010
SOURCE
Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p103507
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The problem of pulse pile-up is very often encountered in precise measurements of γ-rays using germanium detectors. The standard method of treating the pile-up events is to identify and reject them using an appropriate electronic system. Digital acquisition techniques now allow the recording of waveforms of pile-up events that can be analyzed and the contributing single pulses recovered, rather than simply tolerating the losses associated with pile-up. In this paper, a method for the off-line digital processing of pile-up events from germanium detectors is demonstrated. The method is based on an appropriate fitting of the detector signals, shaped with a suitable digital pulse shaper. It is shown that the method is able to recover the pile-up events with good accuracy even when the constituent signals are in close proximity. The method is very useful for γ-ray spectroscopy in nuclear physics experiments, where the low intensity signals can be lost due to the pile-up in a high-rate environment.
ACCESSION #
54858043

 

Related Articles

  • β-decay Spectroscopy at RIBF: The EURICA Project. Lorusso, G.; Nishimura, S.; Baba, H.; Browne, F.; Daido, R.; Doornenbal, P.; Yifan, F.; Gey, G.; Isobe, T.; Jung, H. -S.; Li, Z.; Lubos, D.; Moschner, K.; Nishibata, H.; Patel, Z.; Rice, S.; Sinclair, L.; Söderström, P. -A.; Sumikama, T.; Taprogge, J. // AIP Conference Proceedings;2014, Vol. 1594, p370 

    EURICA is a project at the RIKEN Nishina Center aimed at studying a wide range of exotic nuclei through ß -decay measurements and high-resolution ? -ray spectroscopy. During its first two years of operation, about 80 days of beam time have been dedicated to the project allowing the...

  • γ -ray spectroscopy study of 11ΛB and 12ΛC. Ma, Y.; Ajimura, S.; Aoki, K.; Dairaku, M.; Fu, Y.Y.; Fujioka, H.; Fukuda, T.; Futatsukawa, K.; Hosomi, K.; Imoto, W.; Kawai, M.; Kakiguchi, Y.; Kinoshita, S.; Koike, T.; Maruyama, N.; Mimori, M.; Minami, S.; Miura, Y.; Miwa, K.; Miyagi, Y. // European Physical Journal A -- Hadrons & Nuclei;Sep2007, Vol. 33 Issue 3, p243 

    In this paper, a preliminary result from the latest hypernuclear γ -ray spectroscopy experiment (KEK-E566) is presented together with a short discussion. The experiment was performed at the KEK-PS K6 beam line in 2005. In this experiment, the 12C(π+, K +)12ΛC reaction was employed to...

  • Si(Li) detector parameters optimization using efficiency calibration. Haifa, Ben Abdelwahed; Omrane, Kadri; Adel, Trabelsi // AIP Conference Proceedings;9/19/2007, Vol. 935 Issue 1, p223 

    The efficiency of a Si(Li) detector was determined experimentally and adequately simulated with the GEANT4 code in the energy range from 5 to 27 keV. The point-like sources used were 55Fe, 65Zn, 85Sr, 109Cd and 241Am. For simulation of the detector response we have used a recent version of...

  • Development of advanced x-ray imaging crystal spectrometer utilizing a large area segmented proportional counter for KSTAR. Lee, S. G.; Bak, J. G.; Nam, U. W.; Moon, M. K.; Cheon, J. K. // Review of Scientific Instruments;Jun2007, Vol. 78 Issue 6, p063504 

    An advanced x-ray imaging crystal spectrometer (XICS) for KSTAR tokamak has been developed by utilizing a segmented two dimensional (2D) position-sensitive multiwire proportional counter. The XICS for the KSTAR tokamak provides time-resolved measurements of the radial ion and electron...

  • Current profile reconstruction using electron temperature imaging diagnostics. Tritz, K.; Stutman, D.; Delgado-Aparicio, L. F.; Finkenthal, M.; Pacella, D.; Kaita, R.; Stratton, B.; Sabbagh, S. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p4033 

    Flux surface shape information can be used to constrain the current profile for reconstruction of the plasma equilibrium. One method of inferring flux surface shape relies on plasma x-ray emission; however, deviations from the flux surfaces due to impurity and density asymmetries complicate the...

  • X-ray fluorescence detection of low-Z elements using a microchannel plate detector. Rosenberg, R. A.; Simons, J. K.; Frigo, S. P.; Tan, K.; Chen, J. M. // Review of Scientific Instruments;Apr92, Vol. 63 Issue 4, p2193 

    We demonstrate the utility of a simple, inexpensive, microchannel plate (MCP) detector for monitoring the x-ray fluorescence (XRF) yield in the soft x-ray region. The detector consists of a dual MCP array, and appropriately biased grids. We compare the Al 2p XRF yield to the total-electron yield...

  • In-beam gamma-ray spectroscopy of 254No. Eeckhaudt, S.; Amzal, N.; Bastin, J. E.; Bouchez, E.; Butler, P. A.; Chatillon, A.; Eskola, K.; Gerl, J.; Grahn, T.; Görgen, A.; Greenlees, P. T.; Herzberg, R.-D.; Hessberger, F. P.; Hürstel, A.; Ikin, P. J. C.; Jones, G. D.; Jones, P.; Julin, R.; Juutinen, S.; Kettunen, H. // European Physical Journal A -- Hadrons & Nuclei;Aug2005 Supplement 1, Vol. 25, p605 

    The recoil-tagging technique has been employed to perform an in-beam gamma-ray spectroscopic study of the transfermium nucleus 254No. The experiment was carried out at the Department of Physics of the University of Jyväskylä and utilised the JUROGAM array of germanium detectors coupled to...

  • Use of electron cyclotron resonance x-ray source for nondestructive testing application. Baskaran, R.; Selvakumaran, T. S. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03C101 

    Electron cyclotron resonance (ECR) technique is being used for generating x rays in the low-energy region (<150 keV). Recently, the source is used for the calibration of thermoluminescent dosimetry (TLD) badges. In order to qualify the ECR x-ray source for imaging application, the source should...

  • Low-frequency noise of unipolar nanorectifiers. Balocco, Claudio; Kasjoo, Shahrir R.; Zhang, Linqing Q.; Alimi, Yasaman; Song, Aimin M. // Applied Physics Letters;9/12/2011, Vol. 99 Issue 11, p113511 

    Unipolar nanodiodes, also known as self-switching devices, have recently been demonstrated as terahertz detectors at room temperature. Here, we study their low-frequency noise spectra and noise equivalent power and show that both performance parameters are comparable to those reported for...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics