TITLE

Data processing of absorption spectra from photoionized plasma experiments at Z

AUTHOR(S)
Hall, I. M.; Durmaz, T.; Mancini, R. C.; Bailey, J. E.; Rochau, G. A.
PUB. DATE
October 2010
SOURCE
Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10E324
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We discuss the processing of x-ray absorption spectra from photoionized plasma experiments at Z. The data was recorded with an imaging spectrometer equipped with two elliptically bent potassium acid phthalate (KAP) crystals. Both time-integrated and time-resolved data were recorded. In both cases, the goal is to obtain the transmission spectra for quantitative analysis of plasma conditions.
ACCESSION #
54858028

 

Related Articles

  • Absorption Line Profile of the 5So2-5P1 Transition of Atomic Oxygen and Its Application to Plasma Monitoring. Sasaki, K.; Okumura, Y.; Asaoka, R. // International Journal of Spectroscopy;2010, p1 

    The line profile of the 5So2-5P1 transition of atomic oxygen was measured by diode laser absorption spectroscopy. As a result, it was found that the absorption line profile had a wing component in the wavelength range detuned from the line center and was not fitted with a Gaussian function. The...

  • Time Resolved Radiation Pyrometer For Transient Temperature Measurement. Rav, Amit S.; Saxena, A. K.; Joshi, K. D.; Kaushik, T. C.; Gupta, Satish C. // AIP Conference Proceedings;7/16/2011, Vol. 1349 Issue 1, p451 

    The four channel radiation pyrometer has been developed and used for the measurement of transient temperature profile of copper wire of cross-section diameter 77 μm and length 10 mm heated rapidly to plasma state by deposition of electrical energy within short duration of ∼100 ns. The...

  • High-resolution time-resolved extreme ultraviolet spectroscopy on NSTX. Lepson, J. K.; Beiersdorfer, P.; Clementson, J.; Bitter, M.; Hill, K. W.; Kaita, R.; Skinner, C. H.; Roquemore, A. L.; Zimmer, G. // Review of Scientific Instruments;Oct2012, Vol. 83 Issue 10, p10D520 

    We report on upgrades to the flat-field grazing-incidence grating spectrometers X-ray and Extreme Ultraviolet Spectrometer (XEUS) and Long-Wavelength Extreme Ultraviolet Spectrometer (LoWEUS), at the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Laboratory. XEUS...

  • Following the relaxation dynamics of photoexcited aniline in the 273-266 nm region using time-resolved photoelectron imaging. Thompson, James O. F.; Livingstone, Ruth A.; Townsend, Dave // Journal of Chemical Physics;Jul2013, Vol. 139 Issue 3, p034316 

    Time-resolved photoelectron imaging was used to investigate the relaxation dynamics of electronically excited aniline in the gas-phase following ultraviolet irradiation in the 273-266 nm region. We find that at all wavelengths studied, excitation is predominantly to the long-lived (>1 ns)...

  • Experimental and theoretical study of a capillary discharge dedicated to coherent XUV production. Pons, J.; Lan, Ke; Cachoncinlle, C.; Robert, E.; Viladrosa, R.; Pouvesle, J.-M.; Fleurier, C. // AIP Conference Proceedings;2002, Vol. 641 Issue 1, p107 

    An argon plasma generated by a fast capillary discharge for the amplification of Ar IX 46.9 nm line has been studied experimentally by time-resolved pinhole imaging and XUV spectroscopy. Self breakdown by hollow cathode effect induces plasma ignition along the capillary axis. Numerical...

  • Time-resolved spectra in the 80–330-Ã… wavelength region from PLT tokamak plasmas. Dave, J. H.; Feldman, U.; Seely, J. F.; Wouters, A.; Hinnov, E.; Suckewer, S. // Review of Scientific Instruments;Aug1986, Vol. 57 Issue 8, p2058 

    Time-resolved spectra from the PLT plasma have been recorded by the 2-m Schwob-Fraenkel spectrometer. The recording device was a 50-mm flat multichannel plate mounted with its center tangent to the Rowland circle. In order to record the 80-330-Ã… wavelength range, the multichannel plate was...

  • Time-resolved luminescence spectroscopy of plasma emission from laser ablation of Bi-Sr-Ca-Cu... Fukumura, Hiroshi; Nakaminami, Hiroshi; Eura, Shigeru; Masuhara, Hiroshi; Kawai, Tomoji // Applied Physics Letters;6/3/1991, Vol. 58 Issue 22, p2546 

    Reports on time-resolved spectroscopy of the plasma state produced by laser ablation of Bi-Sr-Ca-Cu oxide superconductor and related materials. Difference in the spectra among samples; Effects of the ambient gas.

  • Multiple-angle, time-resolved spectroscopy of scattered light from laser-produced plasmas (abstract). Bradley, K. S.; Batha, S. H.; Drake, R. P.; Montgomery, D. S. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p5205 

    A new instrument at the NOVA laser facility has been developed to measure absolute levels of scattered light at up to seven angles simultaneously from laser-produced plasmas. The multiple-angle time-resolving spectrometer (MATRS) both temporally (t=120 ps) and spectrally (λ=1 Å) resolves...

  • Spectroscopic Determination of Gradients in Indirect-Drive OMEGA Implosion Cores. Welser, L. A.; Mancini, R. C.; Golovkin, I. E.; Koch, J. A.; Dalhed, H. E.; Lee, R. W.; Marshall, F. J.; Delettrez, J. A.; Klein, L. // AIP Conference Proceedings;2002, Vol. 645 Issue 1, p294 

    We report here on a spectroscopic method for determining the gradient structure in implosion cores based on the self-consistent analysis of simultaneous X-ray monochromatic images and X-ray line spectra. This technique is applied to a series of stable and low convergence indirect drive...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics