TITLE

Strategy for the absolute neutron emission measurement on ITER

AUTHOR(S)
Sasao, M.; Bertalot, L.; Ishikawa, M.; Popovichev, S.
PUB. DATE
October 2010
SOURCE
Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D329
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Accuracy of 10% is demanded to the absolute fusion measurement on ITER. To achieve this accuracy, a functional combination of several types of neutron measurement subsystem, cross calibration among them, and in situ calibration are needed. Neutron transport calculation shows the suitable calibration source is a DT/DD neutron generator of source strength higher than 1010 n/s (neutron/second) for DT and 108 n/s for DD. It will take eight weeks at the minimum with this source to calibrate flux monitors, profile monitors, and the activation system.
ACCESSION #
54857955

 

Related Articles

  • GDT-based neutron source with multiple-mirror end plugs. Beklemishev, A.; Anikeev, A.; Burdakov, A.; Ivanov, A.; Ivanov, I.; Postupaev, V.; Sinitsky, S. // AIP Conference Proceedings;6/19/2012, Vol. 1442 Issue 1, p147 

    We present a new linear trap to be built at the Budker Institute. It combines gasdynamictype central cell with sloshing ions for beam fusion and the multiple-mirror end plugs for improved axial confinement. Thus it is designed as an efficient neutron source and a testbed for future development...

  • Development of in-vessel components of the microfission chamber for ITER. Ishikawa, M.; Kondoh, T.; Ookawa, K.; Fujita, K.; Yamauchi, M.; Hayakawa, A.; Nishitani, T.; Kusama, Y. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D308 

    Microfission chambers (MFCs) will measure the total neutron source strength in ITER. The MFCs will be installed behind blanket modules in the vacuum vessel (VV). Triaxial mineral insulated (MI) cables will carry signals from the MFCs. The joint connecting triaxial MI cables in the VV must be...

  • FUSION'S ROCKY ROAD TO REALITY. Grant, Andrew // Discover;Oct2010, Vol. 31 Issue 8, p77 

    The article presents a timeline of the development of fusion power, from physicists B. Stanley Pons and Martin Fleischmann's creation of a sustained fusion reaction in 1989 to the completion of the National Ignition Facility in 2009.

  • Stability and compressional heating of large field-reversed configurations in the FRX-C/LSM device. Tuszewski, M.; Barnes, D. C.; Rej, D. J.; Taggart, D. P. // Physics of Fluids B: Plasma Physics;Aug91, Vol. 3 Issue 8, p2205 

    Recent data from the FRX-C/LSM device [ Plasma Physics and Controlled Nuclear Fusion Research (IAEA, Vienna, 1989), Vol. II, p. 517] concerning the stability, translation, and compression heating of field-reversed configurations (FRC's) are reported. FRC tilt instabilities are clearly observed...

  • Myxine design for an experimental Galathea reactor. Morozov, A. I.; Nevrovskii, V. A.; Pistunovich, V. I.; Svechkopal, A. N. // Technical Physics;Apr99, Vol. 44 Issue 4, p478 

    Analyzes the fundamental aspects of the design of a myxine with a superconducting chord required for the development of a Galathea fusion reactor. Three-zone radiation-accumulative myxine; Transport and absorption of neutrons and gamma rays; Energy distribution over the minor diameter of the...

  • Time for Japan to shine?  // Nature;2/26/2004, Vol. 427 Issue 6977, p763 

    Discusses the controversy in selecting the site for the International Thermonuclear Experimental Reactor (ITER), an international fusion project. Competition between the European Union, backing a site in Cadarache, France, and Japan, which would build ITER at Rokkasho; Preference expressed by...

  • Design of radial neutron spectrometer array for the International Thermonuclear Experimental Reactor Nishitani, T.; Kasai, S.; Iguchi, T.; Takada, E.; Ebisawa, K.; Kita, Y. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p565 

    Describes the design of a radial neutron spectrometer using a type deuterium-tritium neutron spectrometer base on a recoil proton counter-telescope technique aiming ion temperature measurement for the International Thermonuclear Experimental Reactor. Installation of the neutron spectrometer on...

  • Neutron source strength monitors for ITER Barnes, Cris W.; Roquemore, A. L. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p573 

    Describes a neutron source strength monitor system for the International Thermonuclear Experimental Reactor (ITER). Desired characteristics of the system; Required dynamic range and number of detectors; Fission chamber design; Calibration.

  • Flux calculation in LSNAA using an 241Am-Be source. Khelifi, R.; Bode, P.; Amokrane, A. // Journal of Radioanalytical & Nuclear Chemistry;Dec2007, Vol. 274 Issue 3, p639 

    The CITATION code based on neutron diffusion theory is used for flux calculation inside voluminous sample in prompt gamma activation analysis with an isotopic neutron source (241Am-Be). The code used the specific parameters related to energy spectrum source, irradiation system materials...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics