TITLE

Recent developments of the JET far-infrared interferometer-polarimeter diagnostic

AUTHOR(S)
Boboc, A.; Gelfusa, M.; Murari, A.; Gaudio, P.; JET-EFDA Contributors
PUB. DATE
October 2010
SOURCE
Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D538
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The far-infrared diagnostic provides essential internal measurements of the plasma density and magnetic field topology (q-profile via Faraday rotation angle) in real-time. The diagnostic capabilities have recently been extended in a number of key areas. Fast interferometer data, with 10 μs time resolution, and a new MATLAB code have allowed improved analysis of the evolution of density profiles during fast events such as vertical plasma displacements, edge localized mode, pellet fuelling, and disruptions. Using the polarimeter measurements in real-time, a new calibration procedure has been developed based on a propagation code using the Mueller matrix formalism. A further major upgrade of the system is presently underway: adding a second color laser to the vertical channels and implementing a new phase counter based on analog zero crossing and field-programmable gate array boards.
ACCESSION #
54857932

 

Related Articles

  • The multichannel triple-laser interferometer/polarimeter system at RTP (abstract) Rommers, J. H.; Donne, A. J. H.; Karelse, F. A.; Howard, J. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p446 

    Describes a 19-channel combined interferometer and polarimeter system at the Rijnhuizen Tokamak Project in the Netherlands that is being used to determine the poloidal magnetic field and plasma density distribution simultaneously. Theoretical basis for the method.

  • FIR interferometer/polarimeter system on ISX-B tokamak. Ma, C. H.; Hutchinson, D. P.; Staats, P. A.; Vander Sluis, K. L. // Review of Scientific Instruments;May85, Vol. 56 Issue 5, p911 

    Recent results of simultaneous measurements of electron density and Faraday rotation on all five channels of the FIR interferometer/polarimeter system on ISX-B are presented. The time resolution of the interferometer is typically 1 µs. The standard deviation of the output of the...

  • Influence of refraction on plasma density measurements. Petrov, V. G. // Plasma Physics Reports;Apr2006, Vol. 32 Issue 4, p311 

    The plasma density profile in the T-11M tokamak is measured with a multichannel Cotton-Mouton polarimeter and also with a time-of-flight refractometer. Both instruments operate at frequencies in the range of 140 GHz. Since, in this case, the trajectory of the probing microwave beam deviates from...

  • Short wavelength far infrared laser polarimeter with silicon photoelastic modulators. Akiyama, T.; Kawahata, K.; Tanaka, K.; Okajima, S.; Nakayama, K. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E720 

    A short wavelength far infrared laser whose wavelength λ is about 50 μm is preferable for a polarimeter and an interferometer for high density operations in the Large Helical Device (LHD) and on future large fusion devices such as ITER. This is because the beam bending effect (∝λ2)...

  • High resolution polarimeter-interferometer system for fast equilibrium dynamics and MHD instability studies on Joint-TEXT tokamak (invited). Chen, J.; Zhuang, G.; Li, Q.; Liu, Y.; Gao, L.; Zhou, Y. N.; Jian, X.; Xiong, C. Y.; Wang, Z. J.; Brower, D. L.; Ding, W. X. // Review of Scientific Instruments;2014, Vol. 85 Issue 11, p1 

    A high-performance Faraday-effect polarimeter-interferometer system has been developed for the J-TEXT tokamak. This system has time response up to 1 µs, phase resolution < 0.1° and minimum spatial resolution > 15 mm. High resolution permits investigation of fast equilibrium dynamics as...

  • Prototype studies of the MFTF-B far-infrared interferometer (abstract). Zu, Q. X.; Du, Z. M.; Savage, R. L.; Peebles, W. A.; Luhmann, N. C.; Monjes, J. A.; Throop, A. L.; Thomas, S. R. // Review of Scientific Instruments;May85, Vol. 56 Issue 5, p939 

    A far-infrared (FIR) laser interferometer operating at 185 µm (Difluoremethane) will be used to monitor line integrated plasma density in the high-density center-cell region of the MFTF-B device at the Lawrence Livermore National Laboratory. There are a number of unique physical constraints...

  • Multiple view fan beam polarimetry on Tokamak devices Geck, W. R.; Domier, C. W.; Luhmann, Jr., N. C. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p416 

    Describes a polarimeter diagnostic which utilizes several fan beams to accumulate line integrated Faraday rotation data in a Tokamak plasma. Magnetic expansion technique; Multiple view reconstruction method.

  • Optical layout and mechanical structure of polarimeter-interferometer system for Experimental Advanced Superconducting Tokamak. Zou, Z. Y.; Liu, H. Q.; Jie, Y. X.; Ding, W. X.; Brower, D. L.; Wang, Z. X.; Shen, J. S.; An, Z. H.; Yang, Y.; Zeng, L.; Wei, X. C.; S. Li, G.; Zhu, X.; Lan, T. // Review of Scientific Instruments;2014, Vol. 85 Issue 11, p1 

    A Far-InfaRed (FIR) three-wave POlarimeter-INTerferometer (POINT) system for measurement current density profile and electron density profile is under development for the EAST tokamak. The FIR beams are transmitted from the laser room to the optical tower adjacent to EAST via ~20 m over-moded...

  • Measurements of Faraday rotation in TFTR plasmas. Ma, C. H.; Hutchinson, D. P.; Vander Sluis, K. L.; Mansfield, D. K.; Park, H.; Johnson, L. C. // Review of Scientific Instruments;Aug1986, Vol. 57 Issue 8, p1994 

    Recent results of simultaneous measurements of line electron density and poloidal field-induced Faraday rotation on the multichannel far infrared (FIR) interferometer/polarimeter on tokamak fusion test reactor (TFTR) are presented. The procedures and results of the calibration are described in...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.