Conceptual design of the collection optics for the edge Thomson scattering system in ITER

Yatsuka, E.; Hatae, T.; Suitoh, S.; Aida, Y.; Kusama, Y.
October 2010
Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D541
Academic Journal
Neutron and gamma-ray irradiation complicates the design of the edge Thomson scattering (TS) system in ITER. The TS light is relayed through the relaying optics with labyrinth and fiber coupling optics. Electron density of 2×1019 m-3 is sufficient to measure Te and ne within a 10% and 5% margin of error, respectively, with a spatial resolution of 5 mm. This system can cover from 0.85 to 1 of the normalized minor radius. The time resolution is 10 ms, which is determined by the repetition rate of the laser device. A super-Gaussian is the ideal laser profile for the laser injection optics to avoid a breakdown of the filling gas used in density calibration through Raman scattering.


Related Articles

  • Recent expansion of the TFTR multichannel neutron collimator Roquemore, A. L.; Bitter, M.; Johnson, L. C.; yon Goeler, S. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p544 

    Describes the design, installation and operation of four sight lines in the multichannel neutron collimator on the toroidal fusion test reactor to improve the view in the central region and better evaluate parameters such as global neutron yields and neutron peakedness and to localize neutron...

  • New Thomson scattering diagnostic on RFX-mod. Alfier, A.; Pasqualotto, R. // Review of Scientific Instruments;Jan2007, Vol. 78 Issue 1, p013505 

    This article describes the completely renovated Thomson scattering (TS) diagnostic employed in the modified Reversed Field eXperiment (RFX-mod) since it restarted operation in 2005. The system measures plasma electron temperature and density profiles along an equatorial diameter, measuring in 84...

  • Enhancement of pure volume negative ion production using a grid bias method or a magnetic filter method. Jyobira, Yasuhiro; Ito, Daisuke; Fukumasa, Osamu // Review of Scientific Instruments;Feb2008, Vol. 79 Issue 2, p02A508 

    Volume production of hydrogen negative ion H- is studied in pure hydrogen plasmas using a grid bias method for plasma parameter control. The purposes of the present study are as follows. One is to investigate the possibility of controlling plasma parameters with a grid bias method in dc...

  • Brazilian gamma–neutron dosemeter: response to 241AmBe and 252Cf neutron sources. Souto, E. B.; Campos, L. L. // Radiation Protection Dosimetry;Mar2011, Vol. 144 Issue 1-4, p215 

    With the aim of improving the monitoring of workers potentially exposed to neutron radiation in Brazil, the IPEN/CNEN-SP in association with PRO-RAD designed and developed a passive individual gamma–neutron mixed-field dosemeter calibrated to be used to 241AmBe sources. To verify the...

  • Using k0 in PGAA: Perspectives. Lindstrom, R.M. // Journal of Radioanalytical & Nuclear Chemistry;Sep2003, Vol. 257 Issue 3, p557 

    Prompt-gamma activation analysis (PGAA) differs from conventional neutron activation analysis in the set of elements measured, the irradiation conditions, and the nature of the gamma-ray spectra. Each of these affects the conduct of the measurements and interpretation of the data. In its recent...

  • Resistance of Proton-Irradiated GaAs Photodetectors to Combined Gamma and Neutron Radiation. Murel, A.V.; Obolenski&icaron, S.V.; Fefelov, A.F.; Kiseleva, E.V. // Semiconductors;Jul2004, Vol. 38 Issue 7, p800 

    Characteristics of proton-irradiated epitaxial i-GaAs structures with an interdigitated system of electrodes are studied before and after exposure to combined γ and neutron radiation. In order to reduce the dark current of photodetectors, the electrodes were metallized on proton-irradiated...

  • Interactions of gamma rays with tungsten-doped lead phosphate glasses. ElBatal, Fatma; Marzouk, Samir // Journal of Materials Science;Jun2009, Vol. 44 Issue 12, p3061 

    Undoped lead phosphate glass of the composition PbO 50 mol%, P2O5 50 mol% together with samples of the same ratio doped with various WO3 contents were prepared. UV–Visible spectroscopic studies were measured out in the range 200–1100 nm before and after successive gamma...

  • STRUCTURE, OPTICAL, ELECTRICAL, THERMAL AND ACOUSTICAL PROPERTIES OF NEUTRON IRRADIATED CVD DIAMONDS. Ralchenko, V. G.; Karkin, A. E.; Khomich, A. V.; Poklonski, N. A.; Vlasov, I. I.; Khomich, A. A.; Shiryaev, A. A.; Popovich, A. F.; Klokov, A.Yu.; Sharkov, A. I.; Aminev, D. F.; Poklonskaya, O. N.; Gorbachuk, N. I. // International Conference: Radiation Interaction with Material & ;2012, p342 

    Effects of fast neutron irradiation on spectra of IR absorption, Raman scattering, photoluminescence, acoustical properties, thermal and electrical conductivity of chemical vapor deposited polycrystalline diamond films have been studied.

  • Diagnostic systems in DEMO: engineering design issues. Todd, T. N. // AIP Conference Proceedings;2014, Vol. 1612, p9 

    The diagnostic systems of DEMO that are mounted on or near the torus, whether intended for the monitoring and control functions of the engineering aspects or the physics behaviour of the machine, will have to be designed to suit the hostile nuclear environment. This will be necessary not just...