TITLE

Haemolysis due to active venous drainage during cardiopulmonary bypass: comparison of two different techniques

AUTHOR(S)
Cirri, S.; Negri, L.; Babbini, M.; Latis, G.; Khlat, B.; Tarelli, G.; Panisi, P.; Mazzaro, E.; Bellisario, A.; Borghetti, B.; Bordignon, F.; Ferrara, M.; Pavan, H.; Meco, M.
PUB. DATE
July 2001
SOURCE
Perfusion;Jul2001, Vol. 16 Issue 4, p313
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
To facilitate mini-access for cardiac surgery, two different methods of active venous drainage are used: vacuum assisted drainage and centrifugal pump aspiration on the venous line. The aim of this study was to compare the haemolysis produced using these two techniques. From June to December 1999, 50 consecutive patients were operated on using a ministernotomy. All of these patients had valvular surgery for either valve repair or valve replacement (9 MVRepair, 11 MVR, 29 AVR, 1 AVR 1 MVR). They were randomized into two groups: Group A, 25 patients who underwent surgery where vacuum assisted drainage was used, and Group B, 25 patients where kinetic asssisted venous drainage with centrifugal pump venous aspiration was used. Patient characteristics of both groups were similar for age, gender, body weight, body surface area, height, cardiopulmonary bypass (CPB) time, aortic crossclamp time, priming volume, cardioplegia volume, haemoglobin concentration, haematocrit, serum creatinine, bilirubin, lactate dehydrogenase (LDH), serum glutamic oxaloacetic transaminase (sGOT), serum glutamic pyruvic transaminase (sGPT), aptoglobin, reticulocytes, and platelet count. We checked all these laboratory parameters preoperatively, at the end of CPB, and 2 and 24h after operation. We also checked haemoglobinuria at these same time points. We assessed blood loss at 6, 12, and 24 h after the operation and calculated total postoperative bleeding. There was a tendency towards a greater increase in LDH, sGOT and sGPT in Group A more than in Group B, but these data did not reach statistical significance. Platelet count was always lower in Group A and aptoglobin increased in Group A more than in Group B. More patients in Group A had haemoglobinuria. These findings indicate that haemolysis is increased more in patients treated with vacuum assisted drainage, when compared to the rise in haemolysis in those treated with centrifugal pump venous drainage. Total bleeding is also greater in Group A.
ACCESSION #
5437696

 

Related Articles

  • Isoimmune haemolysis in pathogenesis of anaemia after cardiac surgery. Boughton, B.J.; Galbraith, P.R. // British Medical Journal;11/22/1975, Vol. 4 Issue 5994, p430 

    Describes the isoimmune hemolysis in pathogenesis of anemia after cardiac surgery. Development of antiglobulin-positive hemolytic anemia on patient after receiving multiple transfusions; Fragmentation of erythrocytes; Malfunction of prosthetic heart valves.

  • Excessive negative venous line pressures and increased arterial air bubble counts during miniaturized cardiopulmonary bypass: an experimental study comparing miniaturized with conventional perfusion systems. Aboud, Anas; Liebing, Kai; Börgermann, Jochen; Ensminger, Stephan; Zittermann, Armin; Renner, Andre; Hakim-Meibodi, Kavous; Gummert, Jan // European Journal of Cardio-Thoracic Surgery;Jan2014, Vol. 45 Issue 1, p69 

    OBJECTIVES Miniaturized cardiopulmonary bypass (MCPB) is increasingly used in cardiac surgery, because it can lower clinically significant complications such as systemic inflammatory response, haemolysis and high transfusion requirements. A limitation of MCPB is the risk of excessive negative...

  • Reoperation in a Jehovah's Witness. Dohmen, P.M.; Liu, J.; Lembcke, A.; Konertz, W. // Texas Heart Institute Journal;2003, Vol. 30 Issue 2, p146 

    We report the case of a 29 year-old male Jehovah's Witness who presented with hemolysis and right heart failure as a consequence of extreme calcification of an aortic valve containing allograft and Dacron prosthesis that had been placed 22 years earlier to repair tetralogy of Fallot. Reoperation...

  • Pump-induced haemolysis: a comparison of short-term ventricular assist devices. Bennett, M.; Horton, S.; Thuys, C.; Augustin, S.; Rosenberg, M.; Brizard, C. // Perfusion;Mar2004, Vol. 19 Issue 2, p107 

    Centrifugal pumps are superior to roller pumps for extended support durations in terms of pump-induced haemolysis. In this study, we evaluated the commonly used Biomedicus BP 50 and compared it with the Jostra Rotaflow and a standard roller pump in an in vitro test circuit. Each circuit was run...

  • Evaluation of oxygenators and centrifugal pumps for long-term pediatric extracorporeal membrane oxygenation. Thiara, A. P. S.; Hoel, T. N.; Kristiansen, F.; Karlsen, H. M.; Fiane, A. E.; Svennevig, J. L. // Perfusion;Sep2007, Vol. 22 Issue 5, p323 

    Objective: Two extracorporeal membrane oxygenation (ECMO) circuits for children under 10 kg were evaluated and compared for plasma leakage, hemolysis, blood transfusions, and durability. Methods: Group A (n = 20) was supported by ECMO circuits with the Minimax oxygenator and the Biomedicus...

  • Microhaemodynamics within the blade tip clearance of a centrifugal turbodynamic blood pump. Antaki, J F; Diao, C-G; Shu, F-J; Wu, J-C; Zhao, R; Kameneva, M V; Khir, Ashraf W; Sherwin, Spencer J; Pedley, T J // Proceedings of the Institution of Mechanical Engineers -- Part H;May2008, Vol. 222 Issue 4, p573 

    A persistent challenge facing the quantitative design of turbodynamic blood pumps is the great disparity of spatial scales between the primary and auxiliary flow paths. Fluid passages within journals and adjacent to the blade tips are often on the scale of several blood cells, confounding the...

  • Pathophysiological aspects of cardiotomy suction usage. Svitek, Vladimir; Lonsky, Vladimir; Anjum, Faraz // Perfusion;May2010, Vol. 25 Issue 3, p147 

    Cardiotomy suction is used for preservation of autologous blood during on-pump cardiac surgery at present. Controversially, the exclusion of cardiotomy suction in some types of operations (coronary artery bypass surgery) is not necessarily associated with an increased transfusion requirement. On...

  • DeltaStream: a blood pump that reduces hemolysis during pediatric pulsatile perfusion.  // Cardiology in the Young;May2005 Supplement 2, Vol. 15 Issue S2, p40 

    This article focuses on a study related to DeltaStream, a blood pump that reduces hemolysis during pediatric pulsatile perfusion. Occlusive roller pumps for extra- corporal circulation are widely distributed, but an elevated grade of hemolysis is inevitable when pulsatile perfusion is performed....

  • Closure of a Paravalvular Aortic Leak with the Use of 2 AMPLATZER Devices and Real-Time 2- and 3-Dimensional Transesophageal Echocardiography. Hoffmayer, Kurt S.; Zellner, Christian; Kwan, Damon M.; Konety, Suma; Foster, Elyse; Moore, Phillip; Yeghiazarians, Yerem // Texas Heart Institute Journal;2011, Vol. 38 Issue 1, p81 

    Paravalvular leaks are well-recognized sequelae of mechanical aortic valve implantation. Clinical manifestations include hemolysis, arrhythmias, and congestive heart failure. Frequently, patients who receive mechanical aortic valves are poor candidates for repeat valve surgery, and the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics