TITLE

Scanning Hall probe microscopy with shear force distance control

AUTHOR(S)
Schweinbo¨ck, Thomas; Weiss, Dieter; Lipinski, Martin; Eberl, Karl
PUB. DATE
May 2000
SOURCE
Journal of Applied Physics;5/1/2000, Vol. 87 Issue 9, p6496
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We describe a new type of scanning Hall probe microscope operating at room temperature for quantitative and noninvasive measurements of magnetic stray fields. The probe-sample distance is controlled by piezoelectrical detection of the shear forces acting on an oscillating cantilever. The Hall probes are manufactured from prepatterned GaAs wafers overgrown with a GaAs/AlGaAs heterostructure containing a high-mobility two-dimensional electron gas a few ten nm below the surface. The active Hall area is defined by optical and electron-beam lithography with a junction width of 0.6 μm yielding in a resolution of approximately 0.4 μm. The Hall coefficient of the sensor at room temperature is 0.23 Ω/G with a noise level of ∼0.1 G/Hz1/2. We show measurements of the stray field pattern of bits written on a magnetic hard disk. © 2000 American Institute of Physics.
ACCESSION #
5400963

 

Related Articles

  • High accuracy magnetic field measurements with a Hall probe. Schott, C.; Popovic, R.S.; Alberti, S.; Tran, M.Q. // Review of Scientific Instruments;Jun99, Vol. 70 Issue 6, p2703 

    Describes a silicon-based temperature stabilized axial Hall probe with an absolute accuracy of +/-40 ppm in the range from 0 to 6 T. Hall probe configuration; Magnetic field configuration; Calibration procedure.

  • A calibration method of a radio frequency magnetic probe. Yang, J.G.; Choi, J.H.; Kim, B.C.; Yoon, N.S.; Hwang, S.M. // Review of Scientific Instruments;Sep99, Vol. 70 Issue 9, p3774 

    Demonstrates a simple calibration method of a radio frequency magnetic probe by utilizing a two port network analysis method. Measurement of the scattering parameters; Calculation of the magnetic field generated by the Helmholtz coil; Determination of probe sensitivity.

  • Electrical measurements with a SQUlD susceptometer. Wong, H. K. // Review of Scientific Instruments;Jun91, Vol. 62 Issue 6, p1664 

    We describe the design of a probe that can be inserted into a SQUID susceptometer (S.H.E. model VTS-805) for electrical measurements at variable temperature and high magnetic field. This top-loading probe allows multisample measurements and rapid sample replacement without disturbing the...

  • Calibration of magnetic probes in the vicinity of a conducting well. Howard, S. J.; Horton, R. D.; Hwang, D. Q.; Evans, R. W.; Brockington, S. J. // Review of Scientific Instruments;Feb2008, Vol. 79 Issue 2, p023503 

    Measuring magnetic fields near the edge of a plasma device can be complicated by the geometric effects of the ports through which such measurements are made. The primary effect is an attenuation of the magnetic field at the probe coil due to the field expanding into the finite sized conducting...

  • Noise Measurement of Interacting Ferromagnetic Particles with High Resolution Hall Microprobes. Komatsu, K.; L'Hôte, D.; Nakamae, S.; Ladieu, F.; Mosser, V.; Kerlain, A.; Konczykowski, M.; Dubois, E.; Dupuis, V.; Perzynski, R. // AIP Conference Proceedings;4/23/2009, Vol. 1129 Issue 1, p153 

    We present our first experimental determination of the magnetic noise of a superspin-glass made of <1 pico-liter frozen ferrofluid. The measurements were performed with a local magnetic field sensor based on Hall microprobes operated with the spinning current technique. The results obtained,...

  • NDT Inspections Exploiting Invariances on Scale Transformations. Ramos, Helena Geirinhas; Torres, João; Ribeiro, Artur L.; Rebello, João // AIP Conference Proceedings;2015, Vol. 1650 Issue 1, p327 

    The aim of this paper is to show the invariance on the giant magneto-resistor sensor (GMR) output response in the measurement of different plate thicknesses when the problem is resized. To resize the problem, two different probes were projected, implemented and tested: one, with all the...

  • Liquid helium level detector. Quine, Richard W.; Eaton, Sandra S.; Eaton, Gareth R. // Review of Scientific Instruments;Jun91, Vol. 62 Issue 6, p1647 

    A simple mechanical and electrical design is presented for a small probe for monitoring the level of liquid helium in experimental apparatus or storage Dewars.

  • Electron holography in the study of the leakage field of magnetic force microscope sensor tips. Matteucci, G.; Muccini, M.; Hartmann, U. // Applied Physics Letters;4/12/1993, Vol. 62 Issue 15, p1839 

    Investigates the leakage magnetic field produced by sharp ferromagnetic probes. Application of electron holography; Obtainment of interference fringes; Evaluation of the phase difference in the simulated map of the dipole field.

  • Magnetic field probes for time-domain monitoring of RF exposure within tissue-mimicking materials for MRI-compatible medical device testing. Attaran, Ali; Handler, William B.; Menon, Ravi S.; Chronik, Blaine A. // Electronics Letters;1/11/2018, Vol. 54 Issue 1, p16 

    A new RF B/H field probe for time-domain monitoring of RF electromagnetic-radiated exposure during medical device testing inside the lossy tissue-mimicking material is presented. The probe was tuned and matched for a centre frequency of 127.6 MHz to optimise the response for testing within...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics