TITLE

Effect of Postoperative Mechanical Axis Alignment on the Fifteen-Year Survival of Modern, Cemented Total Knee Replacements

AUTHOR(S)
Parratte, Sebastien; Pagnano, Mark W.; Trousdale, Robert T.; Berry, Daniel J.
PUB. DATE
September 2010
SOURCE
Journal of Bone & Joint Surgery, American Volume;Sep2010, Vol. 92-A Issue 12, p2143
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: One long-held tenet of total knee arthroplasty is that implant durability is maximized when postoperative limb alignment is corrected to 00 ± 3° relative to the mechanical axis. Recently, substantial health-care resources have been devoted to computer navigation systems that allow surgeons to more often achieve that alignment. We hypothesized that a postoperative mechanical axis of 0° ± 3° would result in better long-term survival of total knee arthroplasty implants as compared with that in a group of outliers. Methods: Clinical and radiographic data were reviewed retrospectively to determine the fifteen-year Kaplan-Meier survival rate following 398 primary total knee arthroplasties performed with cement in 280 patients from 1985 to 1990. Preoperatively, most knees were in varus mechanical alignment (mean and standard deviation, 6° ± 8.8° of varus [range, 30° of varus to 22° of valgus]), whereas postoperatively most knees were corrected to neutral (mean and standard deviation, 0° ± 2.8° [range, 8° of varus to 9° of valgus]). Postoperatively, we defined a mechanically aligned group of 292 knees (with a mechanical axis of 0° ± 30) and an outlier group of 106 knees (with a mechanical axis of beyond 00 ± 3°). Results: At the time of the latest follow-up, forty-five (15.4%) of the 292 implants in the mechanically aligned group had been revised for any reason, compared with fourteen (13%) of the 106 implants in the outlier group (p = 0.88); twenty- seven (9.2%) of the 292 implants in the mechanically aligned group had been revised because of aseptic loosening, mechanical failure, wear, or patellar problems, compared with eight (7.5%) of the 106 implants in the outlier group (p = 0.88); and seventeen (5.8%) of the 292 implants in the mechanically aligned group had been revised because of aseptic loosening, mechanical failure, or wear, compared with four (3.8%) of the 106 implants in the outlier group (p = 0.49). Conclusions: A postoperative mechanical axis of 00 ± 3° did not improve the fifteen-year implant survival rate following these 398 modern total knee arthroplasties. We believe that describing alignment as a dichotomous variable (aligned versus malaligned) on the basis of a mechanical axis goal of 0° ± 3° is of little practical value for predicting the durability of modern total knee arthroplasty implants. Level of Evidence: Therapeutic Level Ill. See Instructions to Authors for a complete description of levels of evidence.
ACCESSION #
53906200

 

Related Articles

  • Accuracy of soft tissue balancing in TKA: comparison between navigation-assisted gap balancing and conventional measured resection. Dae-Hee Lee; Jong-Hoon Park; Dong-Ik Song; Debabrata Padhy; Woong-Kyo Jeong; Seung-Beom Han // Knee Surgery, Sports Traumatology, Arthroscopy;Mar2010, Vol. 18 Issue 3, p381 

    Equalized rectangular extension and flexion gaps are considered desirable to ensure proper kinematics in total knee arthroplasty (TKA). We compared soft tissue balancing in TKAs performed using navigation-assisted gap-balancing (60 knees) and conventional measured resection (56 knees). The...

  • What's New in Adult Reconstructive Knee Surgery. Deirmengian, Carl A.; Lonner, Jess H. // Journal of Bone & Joint Surgery, American Volume;1/16/2013, Vol. 95-A Issue 2, p184 

    The article presents updates on adult reconstructive knee surgery. It discusses the design of total knee arthroplasty implants which attempts to improve the functionality of the knee after total knee arthroplasty. It details the introduction of high-flexion total knee arthroplasty designs which...

  • Asymmetrical total knee arthroplasty does not improve patella tracking: a study without patella resurfacing. Barink, Marco; Meijerink, Huub; Verdonschot, Nico; Kampen, Albert; Waal Malefijt, Maarten // Knee Surgery, Sports Traumatology, Arthroscopy;Feb2007, Vol. 15 Issue 2, p184 

    It is often suggested that patella tracking after total knee arthroplasty (TKA) with an asymmetrical patella groove is more physiological than with a symmetrical patella groove. Therefore, this study tried to address two questions: what is the effect of TKA on patella tracking, and is patella...

  • Revision of Unicondylar to Total Knee Arthroplasty: A Systematic Review. Siddiqui, Nashat A.; Ahmad, Zafar M. // Open Orthopaedics Journal;2012 Special Issue 002, Vol. 6 Issue S2, p268 

    Isolated unicompartmental osteoarthritis in the young patient is a difficult problem to treat; they may be too young to consider total knee arthroplasty due to difficulties with inevitable future revision. Unicompartmental knee arthroplasty is one possible solution as it is perceived by some as...

  • Modified gap-balancing technique in total knee arthroplasty: evaluation of the post-operative coronal laxity. Moro-oka, Taka-aki; Shiraishi, Hirokazu; Iwamoto, Yukihide; Banks, Scott A. // Knee Surgery, Sports Traumatology, Arthroscopy;Mar2010, Vol. 18 Issue 3, p375 

    It is unknown how intra-operative soft-tissue balance affects post-operative knee kinematics during different functional tasks. In order to clarify this relationship, the intra-operative varus–valgus balance and post-operative knee kinematics were compared for 17 patients who underwent...

  • Computer-assisted total knee arthroplasty: impact of the surgeon's experience on the component placement. Ballas, Richard; Philippot, Rémi; Cartier, Jean-Loup; Boyer, Bertrand; Farizon, Frédéric // Archives of Orthopaedic & Trauma Surgery;Mar2013, Vol. 133 Issue 3, p397 

    Introduction: Accuracy of implant positioning in total knee arthroplasty (TKA) has a major impact on postoperative outcomes. We investigate the accuracy of positioning of multiples values simultaneously in TKA navigated, even among novice users. Method: The 'novice' group included the first 91...

  • MANAGEMENT OF STIFFNESS FOLLOWING TOTAL KNEE ARTHROPLASTY. Parvizi, Javad; Tarity, T. David; Steinbeck, Marla J.; Politi, Roman G.; Joshi, Ashish; Purtill, James J.; Sharkey, Peter F. // Journal of Bone & Joint Surgery, American Volume;Dec2006 Supplement 4, Vol. 88-A, p175 

    The article offers information on a study that determines the factors responsible for stiffness after total knee arthroplasty. The study findings highlight that individuals undergoing total knee arthroplasty at an earlier age are significantly more likely to have stiffness compared with the...

  • Preoperative Malalignment Increases Risk of Failure After Total Knee Arthroplasty. Ritter, Merrill A.; Davis, Kenneth E.; Davis, Peter; Farris, Alex; Malinzak, Robert A.; Berend, Michael E.; Meding, John B. // Journal of Bone & Joint Surgery, American Volume;1/16/2013, Vol. 95-A Issue 2, p126 

    Background: Implant survival after total knee arthroplasty has historically been dependent on postoperative knee alignment, although failure may occur when alignment is correct. Preoperative knee alignment has not been thoroughly evaluated as a possible risk factor for implant failure after...

  • Late spontaneous haemarthrosis: an unusual complication following an unicompartmental knee arthroplasty. Raet, Jan; Verhaven, Eddy; Kemnitz, Stefan // Knee Surgery, Sports Traumatology, Arthroscopy;Jun2007, Vol. 15 Issue 6, p763 

    A man, aged 55, presented with a spontaneous haemarthrosis of his right knee, 1 year after an unicompartmental knee replacement. This case showed an atraumatic rupture of the metal marker wire of an all-polyethylene inlay tibial implant which caused a destruction of the polyethylene surface and...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics