TITLE

Desarrollo de un Sistema de Monitoreo en Tiempo Real para la Humedad Relativa

AUTHOR(S)
Estrada, M. A.; Rodríguez, S. A.; Caballero, E.; Sarmiento, R.; Racedo, N. F.
PUB. DATE
July 2008
SOURCE
Revista Colombiana de Física;2008, Vol. 40 Issue 2, p382
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
This paper develops the calibration of a system of data acquisition to monitoring the relative humidity in real time using the saturated solutions method, which produce constant relative humidity bath to a given temperature. Relative humidity sensor HIH3610 is introduced in that bath and finally it compared the experimental values of the sensor output voltage with the referenced values by the data sheet.
ACCESSION #
53888567

Tags: HUMIDITY;  ACQUISITION of data;  DETECTORS;  EXPERIMENTS;  PHYSICAL measurements

 

Related Articles

  • DESARROLLO DE UN SISTEMA DE MONITOREO EN TIEMPO REAL DE VARIABLES FISICAS UTILIZANDO SENSORES. Estrada., M. A.; Rodriguez, S. A.; E., Caballero; N. F., Racedo // Revista Colombiana de F�sica;2007, Vol. 39 Issue 2, p661 

    In this work was implemented a system of data acquisition to monitorear physical variables observed in the laboratory using the sensors LM335 and HIH3610 for temperature and relative humidity respectively. A program developed in C++ for the visualization of the behaviour of the variables across...

  • Calibration method to characterize the accuracy of phase-shifting point diffraction interferometer. Liu, Ke; Li, Yanqiu; Wang, Hai // Review of Scientific Instruments;Mar2011, Vol. 82 Issue 3, p033105 

    Characterization of measurement accuracy of the phase-shifting point diffraction interferometer (PS/PDI) is usually performed by two-pinhole null test. In this procedure, the geometrical coma and detector tilt astigmatism systematic errors are almost one or two magnitude higher than the desired...

  • The latest results from the IceCube experiment. Kiryluk, J.; IceCube Collaboration // AIP Conference Proceedings;4/19/2012, Vol. 1441 Issue 1, p454 

    The recently completed IceCube observatory is a 1 km3 neutrino detector with powerful capabilities to explore the Universe. Its primary goal is to observe cosmic neutrinos with energies in the TeV to PeV range. IceCube has been collecting data since the deployment of the first string in 2005. We...

  • Trigger of the KEDR detector. Baru, S.; Talyshev, A.; Telnov, V.; Ukraintsev, Yu.; Usov, Yu.; Shamanaeva, L.; Shamov, A. // Instruments & Experimental Techniques;May2011, Vol. 54 Issue 3, p335 

    The primary and secondary triggers of the KEDR detector operating at the VEPP-4M electron-positron collider of the Budker Institute of Nuclear Physics since 2000 are considered. The detector systems generating the signals, the design of the triggers, the timing characteristics of their...

  • Dewpoint is all done by mirrors.  // Environmental Engineering;Summer2006, Vol. 19 Issue 2, p19 

    The article focuses on the use of mirror technology in measuring humidity. Designed for use inside climatic test chamber, the Optidew from Michell Instruments is being used for measuring dew point ranging from the equivalent of 0.5 to 100 percent relative humidity at temperatures between -40°...

  • Results and recommendations from an intercomparison of six Hygroscopicity-TDMA systems. Massling, A.; Niedermeier, N.; Hennig, T.; Fors, E. O.; Swietlicki, E.; Ehn, M.; Hameri, K.; Villani, P.; Laj, P.; Good, N.; McFiggans, G.; Wiedensohler, A. // Atmospheric Measurement Techniques;2011, Vol. 4 Issue 3, p485 

    The article presents a study on the performance of six custom-built Hygrocopicity-Tandem Differential Mobility Analyser (H-TDMA) systems in the frame of an intercomparison workshop held in Leipzig, Germany. The study states that the goal of the workshop is to develop recommendations for...

  • Techniques for the measurement of disruption halo currents in the National Spherical Torus Experiment. Gerhardt, S. P.; Fredrickson, E.; Guttadora, L.; Kaita, R.; Kugel, H.; Menard, J.; Takahashi, H. // Review of Scientific Instruments;Oct2011, Vol. 82 Issue 10, p103502 

    This paper describes techniques for measuring halo currents, and their associated toroidal peaking, in the National Spherical Torus Experiments [M. Ono et al., Nucl. Fusion 40, 557 (2000)]. The measurements are based on three techniques: (1) measurement of the toroidal field created by the...

  • The Crucible of Physician Performance Reports. Woo, Hawkin E. // JGIM: Journal of General Internal Medicine;Feb2011, Vol. 26 Issue 2, p226 

    Individualized physician performance reports are an emerging phenomena. The narrative piece examines one physician's experience with individualized physician performance reports. Reforming the data collection process could enhance the value of the reports to stakeholders.

  • Digital humidity and temperature sensor.  // DEMM: Engineering & Manufacturing;May2012, p2 

    The article offers information on Bestech Australia's Almemo humidity sensor.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics