TITLE

Fabrication of a hard x-ray sputtered-slice Fresnel phase zone plate

AUTHOR(S)
Kamijo, N.; Tamura, S.; Suzuki, Y.; Handa, K.; Takeuchi, A.; Yamamoto, S.; Ando, M.; Ohsumi, K.; Kihara, H.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p14
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes the fabrication of a Fresnel phase zone plate for hard x ray using physical vapor deposition alternating transparent and opaque layers onto a fine gold wire core 47 micrometers in diameter. Focusing test; Existence of interface roughness of the outer concentric layers in all of the Fresnel zone plates that were fabricated.
ACCESSION #
5327540

 

Related Articles

  • Direct fabrication of polyimide waveguide grating by synchrotron radiation. Kobayashi, Junya; Maruno, Tohru; Ishii, Tetsuyoshi; Tamamura, Toshiaki; Horiuchi, Toshiyuki // Applied Physics Letters;12/7/1998, Vol. 73 Issue 23 

    Synchrotron radiation induces a change in the refractive index of a fluorinated polyimide by an order of 10[sup -2], which is about ten times larger than the change it induces in silica glass irradiated by ultraviolet light, presumably due to fluorine detachment and subsequent volume compaction....

  • X-ray Talbot-Lau interferometer for high-speed phase imaging and tomography using white synchrotron radiation. Olbinado, Margie P.; Harasse, Sébastien; Yashiro, Wataru; Momose, Atsushi // AIP Conference Proceedings;7/31/2012, Vol. 1466 Issue 1, p266 

    The Talbot interferometer using white synchrotron radiation has already been demonstrated for high-speed X-ray phase imaging and tomography as well as four-dimensional phase tomography for an observation of a dynamic specimen. In those previous experiments, the grating lines were oriented...

  • X-ray phase laminography with a grating interferometer using iterative reconstruction. Harasse, Sébastien; Yashiro, Wataru; Momose, Atsushi // AIP Conference Proceedings;7/31/2012, Vol. 1466 Issue 1, p163 

    X-ray phase computed laminography is performed using a Talbot interferometer and synchrotron radiation. An iterative reconstruction algorithm which includes prior information about limited support, range of values and sparsity of the imaged object has been developped. It allows the...

  • The recent development of an X-ray grating interferometer at Shanghai Synchrotron Radiation Facility. Sun, Haohua; Kou, Bingquan; Xi, Yan; Qi, Juncheng; Sun, Jianqi; Mohr, Jürgen; Börner, Martin; Zhao, Jun; Xu, Lisa X.; Xiao, Tiqiao; Wang, Yujie // AIP Conference Proceedings;7/31/2012, Vol. 1466 Issue 1, p243 

    An X-ray grating interferometer has been installed at Shanghai Synchrotron Radiation Facility (SSRF). Three sets of phase gratings were designed to cover the wide X-ray energy range needed for biological and soft material imaging capabilities. The performance of the grating interferometer has...

  • Single-shot X-ray phase-contrast imaging using two-dimensional gratings. Sato, Genta; Itoh, Hidenosuke; Nagai, Kentaro; Nakamura, Takashi; Yamaguchi, Kimiaki; Kondoh, Takeshi; Handa, Soichiro; Ouchi, Chidane; Teshima, Takayuki; Setomoto, Yutaka; Den, Toru // AIP Conference Proceedings;7/31/2012, Vol. 1466 Issue 1, p29 

    We developed a two-dimensional gratings-based X-ray interferometer that requires only a single exposure for clinical radiography. The interferometer consisted of a checkerboard phase grating for π phase modulation and a latticed amplitude grating. Using a synchrotron radiation source, the...

  • X-ray phase imaging-From static observation to dynamic observation-. Momose, A.; Yashiro, W.; Olbinado, M. P.; Harasse, S. // AIP Conference Proceedings;7/31/2012, Vol. 1466 Issue 1, p67 

    We are attempting to expand the technology of X-ray grating phase imaging/tomography to enable dynamic observation. X-ray phase imaging has been performed mainly for static cases, and this challenge is significant since properties of materials (and hopefully their functions) would be understood...

  • Is it feasible a grating based image of a human body? Zhu, Peiping; Wu, Ziyu // AIP Conference Proceedings;7/31/2012, Vol. 1466 Issue 1, p137 

    In this paper we proposed two novel prototypes of grating based tomographic imaging of human body, one based on synchrotron radiation, the other based on the most recent results of carbon nanotube x-ray source array.

  • High-speed X-ray phase tomography with Talbot interferometer and fringe scanning method. Kibayashi, Shunsuke; Harasse, Sébastien; Yashiro, Wataru; Momose, Atsushi // AIP Conference Proceedings;7/31/2012, Vol. 1466 Issue 1, p261 

    High-speed X-ray phase tomography based on the Fourier-transform method has been demonstrated with an X-ray Talbot interferometer using white synchrotron radiation. We report the experimental results of high-speed X-ray phase tomography with fringe-scanning method instead of Fourier-transform...

  • Elimination of higher-order diffraction using zigzag transmission grating in soft x-ray region. Zang, H. P.; Wang, C. K.; Gao, Y. L.; Zhou, W. M.; Kuang, L. Y.; Wei, L.; Fan, W.; Zhang, W. H.; Zhao, Z. Q.; Cao, L. F.; Gu, Y. Q.; Zhang, B. H.; Jiang, G.; Zhu, X. L.; Xie, C. Q.; Zhao, Y. D.; Cui, M. Q. // Applied Physics Letters;3/12/2012, Vol. 100 Issue 11, p111904 

    We present a realization of the sinusoidal transmission function using a series of zigzag-profiled strips where the transmission takes on the binary values 0 and 1 in a two-dimensional distribution. A zigzag transmission grating of 1000 line/mm has been fabricated and demonstrated on the soft...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library