TITLE

In Vivo Electroporation Using an Exponentially Enhanced Pulse: A New Waveform

AUTHOR(S)
Lucas, M. Lee; Jaroszeski, Mark J.; Gilbert, Richard; Heller, Richard
PUB. DATE
March 2001
SOURCE
DNA & Cell Biology;Mar2001, Vol. 20 Issue 3, p183
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
In vivo electroporation is currently accomplished by one of two types of common waveforms: exponential decay or square-wave pulses. The purpose of this report is to present a new electroporation waveform, the exponentially enhanced pulse (EEP). Pulsing protocols including the EEP resulted in high levels of luciferase expression in muscle and skin, equal to or greater than expression resulting from low-voltage, millisecond square-wave pulses. This high level of expression requires fewer pulses when using an EEP protocol. Therefore, similar or greater plasmid DNA expression levels are obtained using fewer pulses with the EEP protocol than with current protocols. This is the first report of this new waveform and shows the success of using protocols employing the EEP to deliver plasmid DNA to various tissue types.
ACCESSION #
5322827

 

Related Articles

  • DSOs catch digital pulses and patterns. Rowe, Martin // Test & Measurement World;Feb98, Vol. 18 Issue 2, p9 

    Focuses on the capabilities of a cathode ray oscillograph. Applications of pulse-width triggering; Creation of delay with the use of event triggers; Options for triggering; Use of trigger in shaft encoders and system clocks. INSET: Digital triggering..

  • Erratum: Appl. Phys. B , 373-376 (2001).  // Applied Physics B: Lasers & Optics;2001, Vol. 72 Issue 8, p977 

    Presents an erratum of the study `Few-cycle optical waveform synthesis,; by A. Poppe, R. Holzwarth, A. Apolonski, G. Tempea, C. Spielman, T.W. Hansch and F. Krausz.

  • Old scopes never die! Epstein, Steve // Broadcast Engineering;Apr98, Vol. 40 Issue 4, p52 

    Presents some of the requests received by the author on the modification for the Tektronix 529 waveform monitor. Requested reprint of the December 1978 issue of `Broadcast Engineering.'

  • Use a trick to count scope events. Montijo, Allen; Travis, Bill // EDN;01/21/99, Vol. 44 Issue 2, p122 

    Presents a hint to provide a quick way to determine, using a digital storage oscilloscope (DSO), how often each of two waveforms occurs. Use of a standard nonaveraging mode to find the voltages of the two states at a fixed point in time.

  • Build a duty-cycle monitor. Campisi, Skip // Popular Electronics;May97, Vol. 14 Issue 5, p45 

    Discusses the ways to make a duty-cycle monitor, instruments that display the real-time cycle reading. Description of the circuit for duty-cycle monitor; How to construct the monitor; Calibration and uses of the monitor. INSET: Parts list for the duty-cycle monitor..

  • WAVEFORM MONITOR AND RASTERIZER.  // Broadcast Engineering (World Edition);Aug2011, Vol. 53 Issue 8, p34 

    The article presents information related to WFM5200 waveform monitor and WVR5200 rasterizer monitor from Tektronix Inc.

  • Arbitrary waveform generator.  // Machine Design;4/18/94, Vol. 66 Issue 8, p43 

    Features the WaveStation 400 Series arbitrary waveform generator (AWG) of LeCroy.

  • 50M-sample/sec arbitrary-waveform generator doubles as 64-bit pattern generator. Strassberg, Dan // EDN;7/6/95, Vol. 40 Issue 14, p22 

    Focuses on Wavetek Corp.'s Model 296 arbitrary-waveform generator. Features; Applications; Performance; Price; Contact information.

  • High-end DSO provides fast insights into signal behavior. Strassberg, Dan // EDN;3/7/2002, Vol. 47 Issue 5, p17 

    Introduces the Wavemaster 8500 of Lecroy for insights into the meaning of complex waveforms. Creation of complex calculations on acquired data; Clarity of the Wavemaster 8500; Complex calculation required for waveform analysis.