TITLE

Ultra-fast two-dimensional microchip electrophoresis using SDS μ-CGE and microemulsion electrokinetic chromatography for protein separations

AUTHOR(S)
Osiri, John K.; Shadpour, Hamed; Soper, Steven A.
PUB. DATE
September 2010
SOURCE
Analytical & Bioanalytical Chemistry;Sep2010, Vol. 398 Issue 1, p489
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A poly(methyl methacrylate) microfluidic chip was used to perform a two-dimensional (2-D) separation of a complex protein mixture in short development times. The separation was performed by combining sodium dodecyl sulfate micro-capillary gel electrophoresis (SDS μ-CGE) with microemulsion electrokinetic chromatography (μ-MEEKC), which were used for the first and second dimensions, respectively. Fluorescently labeled Escherichia coli cytosolic proteins were profiled by this 2-D approach with the results compared to a similar 2-D separation using SDS μ-CGE × μ-MEKC (micelle electrokinetic chromatography). The relatively short column lengths (effective length = 10 mm) for both dimensions were used to achieve separations requiring only 220 s of development time. High spot production rates (131 ± 11 spots min−1) and reasonable peak capacities (481 ± 18) were generated despite the fact that short columns were used. In addition, the use of μ-MEEKC in the second dimension was found to produce higher peak capacities compared to μ-MEKC (481 ± 18 for μ-MEEKC and 332 ± 17 for μ-MEKC) due to the higher plate numbers associated with μ-MEEKC.
ACCESSION #
52815207

 

Related Articles

  • Isolation and Detection of Proteins with Nano-Particles and Microchips for Analyzing Proteomes on a Large Scale Basis. Ki Chan; Tzi Bun Ng // Protein & Peptide Letters;Apr2011, Vol. 18 Issue 4, p423 

    No abstract available.

  • Look, no hands. Gershon, Diane // Nature;7/31/2003, Vol. 424 Issue 6948, p583 

    A recurring theme in proteomics is the demand for greater automation to increase efficiency and reproducibility. Fullerton, California-based Beckman Coulter has modified and repositioned some of its products under the name ProteomeLab. With the PF 2D automated, two-dimensional...

  • Determination of adrenal steroids by microfluidic chip using micellar electrokinetic chromatography. Shen, Shuanglong; Li, Yan; Wakida, Shin-ichi; Takeda, Sahori // Environmental Monitoring & Assessment;Jun2009, Vol. 153 Issue 1-4, p201 

    This paper describes a sensitive and convenient method to separate progesterone, 17α-hydroxy progesterone, cortexolone, hydrocortisone and cortisone, all of which are steroids and have similar structures, using microfluidic chip-based technology with UV detection at 252 nm. We successfully...

  • Potential for Ultrafast Protein Separations with Capillary-Channeled Polymer (C-CP) Fiber Columns. Nelson, Dwella M.; Marcus, R. Kenneth // Protein & Peptide Letters;Jan2006, Vol. 13 Issue 1, p95 

    Capillary-channeled polymer (C-CP) fibers are demonstrated as a potential stationary phase for liquid chromatography separation of protein mixtures. Separation of a synthetic mixture of four proteins is accomplished within a 45-second window using a conventional revered-phase (RP) gradient, at a...

  • Proteomics technology: Character references.  // Nature;10/25/2001, Vol. 413 Issue 6858, p869 

    Reports on the development of mass spectrometry and 2D-gel technology used to separate individual proteins from complex mixtures. Modernization of the chromatography; Integration of more steps of the overall proteomics workflow into fewer pieces of equipment; General technique of isolating and...

  • Regenerated Cellulose Membrane with Different Spacer Arm Length of Diamine Monomer for Membrane Chromatography. Yue Wei Lee; Saufi, Syed M. // Advances in Environmental Biology;Special2014, Vol. 8 Issue 3, p596 

    Packed bed column chromatography is widely used for protein separation. However, it has several limitations such as high pressure drop and long processing times. Membrane chromatography is an alternative technique used for protein separation. Specific monomer can be grafted to uncharged membrane...

  • Simplified purification of equine chorionic gonadotropin (eCG)--an example of the use of magnetic microsorbents for the isolation of glycoproteins from serum. Müller, Christine; Wagner, Kerstin; Frankenfeld, Katrin; Franzreb, Matthias // Biotechnology Letters;May2011, Vol. 33 Issue 5, p929 

    Classical purification of the glycoprotein equine chorionic gonadotropin (eCG) from serum includes pH fractionation with metaphosphoric acid, two ethanol precipitation steps as well as dialysis followed by fixed-bed chromatography. A simplified process requiring only 1/3 of the solvent and...

  • Protein separation on a polar-copolymerized C stationary phase. Jun Dong; Long Yu; Xiuli Zhang; Xingya Xue; Zhimou Guo; Xinmiao Liang // Analytical & Bioanalytical Chemistry;May2011, Vol. 399 Issue 10, p3415 

    novel polar-copolymerized C stationary phase composed of octyl and chloropropyl (C-CCl)-bonded silica has been developed for protein separation. Separation of standard proteins on this homemade column was investigated and compared with separation on a Waters Symmetry 300 C column. Results...

  • Guidelines for reporting the use of column chromatography in proteomics. Jones, Andrew R.; Carroll, Kathleen; Knight, David; MacLellan, Kirsty; Domann, Paula J.; Legido-Quigley, Cristina; Lihua Huang; Smallshaw, Lance; Mirzaei, Hamid; Shofstahl, James; Paton, Norman W. // Nature Biotechnology;Jul2010, Vol. 28 Issue 7, p654 

    The article offers information on the column chromatography module (MIAPE-CC) of the minimum information about a proteomics experiment (MIAPE) guidelines developed by proteomics research working under the aegis of the Human Proteome Organisation's Proteomics Standards Initiative (HUPO-PSI). The...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?