TITLE

Solid-state Marx based two-switch voltage modulator for the On-Line Isotope Mass Separator accelerator at the European Organization for Nuclear Research

AUTHOR(S)
Redondo, L. M.; Silva, J. Fernando; Canacsinh, H.; Ferrão, N.; Mendes, C.; Soares, R.; Schipper, J.; Fowler, A.
PUB. DATE
July 2010
SOURCE
Review of Scientific Instruments;Jul2010, Vol. 81 Issue 7, p074703
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A new circuit topology is proposed to replace the actual pulse transformer and thyratron based resonant modulator that supplies the 60 kV target potential for the ion acceleration of the On-Line Isotope Mass Separator accelerator, the stability of which is critical for the mass resolution downstream separator, at the European Organization for Nuclear Research. The improved modulator uses two solid-state switches working together, each one based on the Marx generator concept, operating as series and parallel switches, reducing the stress on the series stacked semiconductors, and also as auxiliary pulse generator in order to fulfill the target requirements. Preliminary results of a 10 kV prototype, using 1200 V insulated gate bipolar transistors and capacitors in the solid-state Marx circuits, ten stages each, with an electrical equivalent circuit of the target, are presented, demonstrating both the improved voltage stability and pulse flexibility potential wanted for this new modulator.
ACCESSION #
52616358

 

Related Articles

  • Flash-lamp-triggered high-power thyratron-type switch. Kirkman, G.; Hartmann, W.; Gundersen, M. A. // Applied Physics Letters;2/22/1988, Vol. 52 Issue 8, p613 

    Extremely high cold cathode emission and a plasma current density that is much higher than commercial glow discharge hot cathode switches have been obtained in a flash-triggered hollow cathode thyratron-type switch that operates in a glow mode. The cold cathode emission is higher by several...

  • Large-bore copper vapor laser with a double thyratron pulse modulator. Singh, B.; Nakhe, S. V.; Mittal, J. K.; Dixit, S. K.; Vora, H. S.; Bhatnagar, R. // Review of Scientific Instruments;Feb1993, Vol. 64 Issue 2, p314 

    Use of a double thyratron pulse modulator in a large-bore copper vapor laser is demonstrated. Design of the laser consisting of a discharge tube of 70-mm diameter and 1500-mm length is discussed. The laser gave 55-W output power at 4.8-kHz repetition rate using neon as the buffer gas with 9.1-kW...

  • Radiation protection study related to the future post-accelerator of the HIE-ISOLDE project. Giron, S.; Vollaire, J.; Dorsival, A. // Radiation Protection Dosimetry;Oct2014, Vol. 161 Issue 1-4, p321 

    The HIE-ISOLDE project aims at expanding the physics programme of the ISOLDE facility at CERN. In particular, the addition of a superconducting linac will allow the post-acceleration of radioactive ion beams up to 10 MeV/u. However, because of field emission in the superconducting cavities and...

  • Toward ultracompact pseudospark switches. Jiang, Chunqi; Kuthi, Andras; Gundersen, Martin A. // Applied Physics Letters;1/10/2005, Vol. 86 Issue 2, p024105 

    This letter reports studies of small pseudospark switches wherein the volume is reduced by one order of magnitude relative to the smallest previously reported versions operating with a peak current >1 kA. In preliminary testing, the switch holds off >20 kV with a peak current >4 kA and a pulse...

  • Operation and thermal modeling of the ISIS H- source from 50 to 2 Hz repetition rates. Pereira, H.; Faircloth, D.; Lettry, J. // AIP Conference Proceedings;Feb2013, Vol. 1515 Issue 1, p114 

    CERN's Linac4 accelerator H- ion source, currently under construction, will operate at a 2 Hz repetition rate, with pulse length of 0.5 ms and a beam current of 80 mA. Its reliability must exceed 99 % with a mandatory 3 month uninterrupted operation period. A Penning ion source is successfully...

  • Charge state breeding of radioactive isotopes for ISAC. Ames, F.; Baartman, R.; Bricault, P.; Jayamanna, K. // Hyperfine Interactions;Feb2014, Vol. 225 Issue 1-3, p63 

    For the acceleration of radioactive isotopes with a mass greater than 30 amu charge breeding with an electron cyclotron resonance ion source (ECRIS) is being used at ISAC. Singly charged ions from the target ion source combination are injected into a 14.5 GHz ECRIS from PANTECHNIK and charge...

  • ARIEL front end. Marchetto, M.; Baartman, R. A.; Laxdal, R. E. // Hyperfine Interactions;Feb2014, Vol. 225 Issue 1-3, p275 

    The ARIEL project at TRIUMF will greatly expand the variety and availability of radioactive ion beams (RIBs) (Laxdal, Nucl Inst Methods Phys Res B 204:400–409, 2003 ). The ARIEL front end connects the two ARIEL target stations to the existing ISAC facility to expand delivery to two and...

  • Rare isotope beams at ISAC–target & ion source systems. Bricault, Pierre G.; Ames, Friedhelm; Dombsky, Marik; Kunz, Peter; Lassen, Jens // Hyperfine Interactions;Feb2014, Vol. 225 Issue 1-3, p25 

    The present status of the ISAC facility for rare isotopes beams after its first 10 years of operation is presented. Planning for the ISAC facility started in 1985 with the Parksville workshop on radioactive ion beams (Buchmann and D’Auria 1985 ). It was put on halt by the KAON proposal...

  • The GRIFFIN spectrometer. Svensson, C. E.; Garnsworthy, A. B. // Hyperfine Interactions;Feb2014, Vol. 225 Issue 1-3, p127 

    Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei (GRIFFIN) is an advanced new high-efficiency γ-ray spectrometer being developed for use in decay spectroscopy experiments with low-energy radioactive ion beams provided by TRIUMF’s Isotope Separator and Accelerator...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics