TITLE

Low-Cost Dedicated Outdoor-Air Systems

AUTHOR(S)
West, Michael
PUB. DATE
July 2010
SOURCE
Heating/Piping/Air Conditioning Engineering;Jul2010, Vol. 82 Issue 7, p42
SOURCE TYPE
Periodical
DOC. TYPE
Article
ABSTRACT
The article explains the engineering aspects of two dedicated outdoor-air systems (DOAS)-related innovations. It helps engineers in achieving an equal or better performance without the complexities and cost of a reheat coil and controls. It adds that the inherent simplicity makes DOAS lower in cost than comparable units that rely on enthalpy wheels or hot-gas or liquid reheat coils and controls. It further outlines the compelling advantages of DOAS.
ACCESSION #
52409755

 

Related Articles

  • Humidity Control, IAQ.  // ASHRAE Journal;Jul2011, Vol. 53 Issue 7, p140 

    The article offers brief information on several indoor air quality (IAQ) products including the Wireless IAQ Profile PPMonitor from PPM Technology Ltd., PreVent air intake filters from Permatron Corp., and the UWRI-2-NEMA wireless relativity humidity transmitter from Omega Engineering Inc.

  • Standard 62.1 Update & Plans. HEDRICK, ROGER // ASHRAE Journal;Aug2014, Vol. 56 Issue 8, p86 

    The article focuses on the changes included in the revised and updated U.S. building technology society ASHRAE's Standard 62.1-2013, Ventilation for Acceptable Indoor Air Quality, in 2014. Topics discussed include the modification of the requirements for the quality of water used in...

  • The Analysis of Comfortable and Energy Saving of Ice-Storage Low Temperature Air Supply System. Li Bai; Xuezhi Zhou; Yan Wang; Yawei Hua // Advanced Materials Research;2014, Vol. 960-961, p635 

    More and more attentions have been paid on ice-storage low temperature air supply system because of its notable energy saving effects and comfort. The paper expatiate on that ice-storage low temperature air supply system brings a series of especial superiority to modern air-condition cause. The...

  • ENERGY RECOVERY VENTILATION. Dieckmann, John // ASHRAE Journal;Aug2008, Vol. 50 Issue 8, p38 

    The article focuses on the energy recovery ventilation (ERV) which is a proven means of reducing cooling and heating loads in energy use in the U.S. ERV is applied with an air-to-air enthalpy exchanger and has a positive impact on building humidity control for it removes a large amount of the...

  • Modular dehumidifiers offer design flexibility.  // Air Conditioning Heating & Refrigeration News;2/27/95, Vol. 194 Issue 9, p22 

    Reports that the Cargocaire Division of Munters Corp. introduced a line of dehumidifiers designed for flexibility through optional add-on modules. Features of the HCD 6000 through 9000 product line; Other Cargocaire announcements at the 1995 IAHR Expo.

  • These dehumidifiers pose no Y2K threat, says mfr.  // Air Conditioning Heating & Refrigeration News;08/16/99, Vol. 207 Issue 16, p6 

    Reports on Cargocaire's claim that no problems will occur with its dessicant dehumidification equipment upon the arrival of January 1, 2000. Programmable logic controller (PLC) in the company's dehumidifiers as not using clock-sensitive microprocessors; Use of non-calendar-based timers; Contact...

  • Humidification, energy-recovery products grow to meet needs.  // Air Conditioning Heating & Refrigeration News;3/11/96, Vol. 197 Issue 11, p64 

    Reports on the launch of humidification products at the 1996 International Air-Conditioning, Heating, Refrigerating Exposition. Air Technology Systems Inc.'s applications in its VFS series; Desert Aire's line of humidity and temperature controls; Herrmidifier's range of products from...

  • Dehumidification market is strong overseas.  // Air Conditioning, Heating & Refrigeration News;3/21/94, Vol. 191 Issue 12, p18 

    Reports on the performance of Heat Controller Inc.'s Century and Comfort-Aire heating and air conditioning equipment in the export market. Popularity of United States (US) dehumidifier in the export market due to its quality and value; Number of units shipped annually by Heat Controller;...

  • DESICCANT DEHUMIDIFICATION SYSTEMS RESOLVE MOLD ISSUES AT SCHOOL.  // Engineered Systems;Nov2004 Supplement, Vol. 21, p10 

    Focuses on the effort of the Pharr-San Juan-Alamo School District to identify problems and solutions related to molds that grew on ceilings,walls, equipment and books at the district's memorial high school by contracting Assured Indoor Air Quality. Identification of humidity in outside air drawn...