TITLE

Influence of Nebulizer Type, Position, and Bias Flow on Aerosol Drug Delivery in Simulated Pediatric and Adult Lung Models During Mechanical Ventilation

AUTHOR(S)
Ari, Arzu; Atalay, Orcin Telli; Harwood, Robert; Sheard, Meryl M.; Aljamhan, Essam A.; Fink, James B.
PUB. DATE
July 2010
SOURCE
Respiratory Care;Jul2010, Vol. 55 Issue 7, p845
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
BACKGROUND: The effectiveness of aerosol drug delivery during mechanical ventilation is influenced by the patient, ventilator, and nebulizer variables. The impact of nebulizer type, position on the ventilator circuit, and bias flow on aerosol drug delivery has not been established for different age populations. OBJECTIVE: To determine the influence of nebulizer position and bias flow with a jet nebulizer and a vibrating-mesh nebulizer on aerosol drug delivery in simulated and mechanically ventilated pediatric and adult patients. METHOD: Albuterol sulfate (2.5 mg) was nebulized with a jet nebulizer and a vibrating-mesh nebulizer, using simulated pediatric and adult lung models. The 2 nebulizer positions were: (1) jet nebulizer placed 15 cm from the Y-piece adapter, and vibrating-mesh nebulizer attached directly to the Y-piece; and (2) jet nebulizer placed prior to the heated humidifier with 15 cm of large-bore tubing, and vibrating-mesh nebulizer positioned at an inlet to the humidifier. A ventilator with a heated humidifier and ventilator circuit was utilized in both lung models. The adult ventilator settings were VT 500 mL, PEEP 5 cm H2O, respiratory rate 20 breaths/min, peak inspiratory flow 60 L/min, and descending ramp flow waveform. The pediatric ventilator settings were VT 100 mL, PEEP 5 cmH2O, respiratory rate 20 breaths/ min, inspiratory time 1 s. We tested bias flows of 2 and 5 L/min. The adult and pediatric lung models used 8-mm and 5-mm inner-diameter endotracheal tubes, respectively. Each experiment was run 3 times (n = 3). The albuterol sulfate was eluted from the filter and analyzed via spectrophotometry (276 nm). RESULTS: Nebulizer placement prior to the humidifier increased drug delivery with both the jet nebulizer and the vibrating-mesh nebulizer, with a greater increase with the vibrating-mesh nebulizer. Higher bias flow reduced drug delivery. Drug delivery with the vibrating-mesh nebulizer was 2-4-fold greater than with the jet nebulizer at all positions (P < .05) in both lung models. CONCLUSION: During simulated mechanical ventilation in pediatric and adult models, bias flow and nebulizer type and position impact aerosol drug delivery.
ACCESSION #
52060395

 

Related Articles

  • Evaluation of Aerosol Generator Devices at 3 Locations in Humidified and Non-humidified Circuits During Adult Mechanical Ventilation. Ari, Arzu; Areabi, Hasan; Fink, James B. // Respiratory Care;Jul2010, Vol. 55 Issue 7, p837 

    BACKGROUND: The position of the jet or ultrasonic nebulizer in the ventilator circuit impacts drug delivery during mechanical ventilation, but has not been extensively explored, and no study has examined all of the commonly used nebulizers. METHODS: Drug delivery from jet, vibratingmesh, and...

  • Nebulized Drug Delivery in Patients Breathing Spontaneously Through an Artificial Airway. Mir, Muhammad; Dhand, Rajiv // Respiratory Care;Jul2012, Vol. 57 Issue 7, p1195 

    The authors highlight artificial airways, as an obstacle in effective aerosol delivery during mechanical ventilation its impact on patient care in the intensive care unit (ICU). They also introduce and discuss a study "An in vitro evaluation of aerosol delivery through tracheostomy and...

  • Measurement of diaphragm loading during pressure support ventilation. Fauroux, Brigitte; Hart, Nicholas; Luo, Yuan M.; MacNeill, Stephanie; Moxham, John; Lofaso, Frédéric; Polkey, Michael I.; Lofaso, Frédéric // Intensive Care Medicine;Nov2003, Vol. 29 Issue 11, p1960 

    Objective: The diaphragmatic pressure-time product (PTPdi) has been used to quantify the loading and unloading of the diaphragm. The validity of the relationship between PTPdi and diaphragm electrical activity (EMGdi) during pressure-support ventilation (PSV) is unclear. We examined...

  • STRAIGHT TALK.  // RT: The Journal for Respiratory Care Practitioners;Aug2007, Vol. 20 Issue 8, p24 

    An interview with John Power, managing director of Aerogen Ireland Ltd., about aerosol delivery. He reveals that the latest trends in aerosol delivery include device refinement to improve aerosol delivery of existing therapies. He discusses how the products of Aerogen have incorporated the...

  • Anaesthesia Ventilators. Jain, Rajnish K.; Swaminathan, Srinivasan // Indian Journal of Anaesthesia;Sep/Oct2013, Vol. 57 Issue 5, p525 

    Anaesthesia ventilators are an integral part of all modern anaesthesia workstations. Automatic ventilators in the operating rooms, which were very simple with few modes of ventilation when introduced, have become very sophisticated with many advanced ventilation modes. Several systems of...

  • Salbutamol delivery during non-invasive mechanical ventilation in patients with chronic obstructive pulmonary disease: a randomized, controlled study. Nava, S.; Karakurt, S.; Rampulla, C.; Braschi, A.; Fanfulla, F. // Intensive Care Medicine;Oct2001, Vol. 27 Issue 10, p1627 

    Objective: We investigated the clinical response to equivalent doses of salbutamol delivered, via metered dose inhaler (MDI) during non-invasive mechanical ventilation (NIMV-MDI), during spontaneous breathing using a spacer (MDI-Spacer), and also during intermittent positive...

  • FOLLOW THE ARROW: AN EVALUATION OF THE AERONEB® SOLO ADULT T-PIECE DIRECTION ON DOSE DELIVERY IN AN IN-VITRO MODEL.  // Respiratory Care;Oct2014, Vol. 59 Issue 10, pOF30 

    An abstract of the article "Follow the Arrow: An Evaluation of the Aeroneb Solo Adult T-Piece Direction on Dose Delivery in an In-Vitro Model" by Meagan N. Dubosky and David L. Vines is presented.

  • Dry powder inhalers: challenges and goals for next generation therapies. Hak-Kim CHan; Young, Paul M.; Traini, Daniela; Coates, Matthew // Pharmaceutical Technology Europe;Apr2007, Vol. 19 Issue 4, p19 

    This article describes the latest developments in dry powder inhaler (DPI) systems, including the nature and production of active pharmaceutical ingredient particles, formulation considerations for powder blends, and recent developments in DPI devices.

  • Methods of delivering drugs. Rees, John // BMJ: British Medical Journal (International Edition);9/3/2005, Vol. 331 Issue 7515, p504 

    Focuses on different types of medical devices used to administer drugs through inhalation to patients. Description of several inhalers, including metered does, CFC-free, spacer and dry powder; Nebulisers, tablets, syrups and injections; How these devices work to deliver medication.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics