TITLE

Research Activities Using Indus-1 Synchrotron Radiation Source

AUTHOR(S)
Lodha, G. S.; Deb, S. K.
PUB. DATE
June 2010
SOURCE
AIP Conference Proceedings;6/24/2010, Vol. 1234 Issue 1, p277
SOURCE TYPE
Conference Proceeding
DOC. TYPE
Article
ABSTRACT
Indus-1 is an efficient SR source in the soft x-ray / vacuum ultra violet region of the electromagnetic spectrum. For Indus-1, the higher order energy contamination in soft x-ray region, heat load and radiation safety problems are also significantly low. At present, soft x-ray-VUV reflectivity, angle integrated and angle resolved photo electron spectroscopy (ARPES), photo physics and high resolution vacuum ultra violet spectroscopy, beamlines are operational. The paper presents some of the recent studies carried out using In-dus-1.
ACCESSION #
51975509

 

Related Articles

  • Soft x-ray spectroscopy beamline 6 m high energy spherical grating monochromator at SRRC: Optical... Chung, S.-C.; Chen, C.-I.; Tseng, P.-C.; Lin, H.-F.; Dann, T.E.; Song, Y.-F.; Huang, L.-R.; Chen, C.-C.; Chuang, J.-M.; Tsang, K.-L.; Chang, C.-N. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1655 

    Describes the layout and first data on the performance of the soft x-ray bending magnet beamline six-meter high energy spherical grating monochromator at the Synchrotron Radiation Research Center in Taiwan. Beamline design; Photon flux; High order harmonic contamination; Energy resolution.

  • The Exploitation of Multichannel Detection in Scanning Photoemission Microscopy. Potts, A. W.; Morrison, G. R.; Gregoratti, L.; Barinov, A.; Kaulich, B.; Kiskinova, M. // Surface Review & Letters;Apr2002, Vol. 9 Issue 2, p705 

    Sub-micrometer resolution has been achieved in photoemission microscopy thanks to the high flux and brightness of the soft X-rays provided by third generation synchrotron sources and the progress in microfabrication of focusing elements. The use of multichannel detectors in recently constructed...

  • A study on background subtraction in Auger and photoelectron time coincidence spectroscopy... Calicchia, P.; Lagomarsino, S.; Scarinci, F.; Martinelli, C. // Review of Scientific Instruments;Sep99, Vol. 70 Issue 9, p3529 

    Conducts Auger and photoelectronic time coincidence spectroscopy measurements on Si(100) employing third generation synchrotron radiation source. Time structure characteristics of the European Synchrotron Radiation Facility light source; Influence of the source in the distribution of accidental...

  • Performances and first experimental results of BACH, the beamline for dichroism and scattering experiments at ELETTRA. Zangrando, M.; Zacchigna, M.; Bondino, F.; Finazzi, M.; Pardini, T.; Platè, M.; Rochow, R.; Cocco, D.; Parmigiani, F.; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p324 

    BACH, the new soft x-ray beamline for polarization dependent experiments at the Italian synchrotron radiation facility ELETTRA, has been commissioned, characterized and opened to external users. Based on two APPLE II undulators, it covers an energy range between 35 eV and 1600 eV with the...

  • The Advanced Light Source Upgrade. Chemla, D. S.; Feinberg, B.; Hussain, Z.; Krebs, G. F.; Padmore, H. A.; Robin, D. S.; Robinson, A. L.; Smith, N. V.; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p145 

    The ALS, a third-generation synchrotron light source at Berkeley Lab, has been operating for almost a decade and is generating forefront science by exploiting the high brightness of a third-generation source in three areas: (1) high resolving power for spectroscopy; (2) high spatial resolution...

  • An evaluation of multilayer mirrors for the soft x ray and extreme ultraviolet wavelength range that were irradiated with neutrons Regan, S. P.; May, M. J.; Soukhanovskii, V.; Finkenthal, M.; Moos, H. W.; Farnum, E. H.; Clinard, Jr., F. W.; Tarrio, C.; Watts, R. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p757 

    Presents the results of an evaluation of multilayer mirrors (MLM) for the soft x ray and extreme ultraviolet wavelength range that were irradiated with neutrons. Wavelength resolution of MLM devices; MLM irradiation experiment; Reflectivity measurements; Thermal properties of MLM containing...

  • Narrow bandpass multilayer x-ray monochromator. Sammar, A.; Krastev, K.; Andre, J.-M.; Barchewitz, R. // Review of Scientific Instruments;Aug1997, Vol. 68 Issue 8, p2969 

    Proposes a method to reduce the bandpass of soft x-ray multilayer Bragg reflectors. Components and theoretical principles of the narrow bandpass monochromator; Methods used to design the monochromator; Performance testing of the device.

  • Development of Multilayer Analyzer Array Detectors for X-ray Fluorescence at the Third Generation Synchrotron Source. Zhang, K.; Rosenbaum, G.; Liu, R.; Liu, C.; Carmeli, C.; Bunker, G.; Fischer, D.; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p957 

    The development of Multilayer Analyzer Array Detector (MAAD) for X-ray fluorescence eliminates the count rate limitation encountered with multi-element Ge detectors. A 24-element multilayer detector has been fabricated that is tunable in a large energy region. This detector has been operational...

  • Grazing incidence X-ray scattering and diffraction. Basu, Jaydeep // Resonance: Journal of Science Education;Dec2014, Vol. 19 Issue 12, p1158 

    The advent of dedicated powerful synchrotron Xray sources worldwide has lead to the growth of the most recent branch of X-ray diffraction and scattering - surface X-ray scattering and diffraction. In thia article, various aspects of surface Xray diffraction and scattering are discussed with...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics