TITLE

Oxygenator change-out times: the value of a written protocol and simulation exercises

AUTHOR(S)
Darling, Edward; Searles, Bruce
PUB. DATE
May 2010
SOURCE
Perfusion;May2010, Vol. 25 Issue 3, p141
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A survey by our department revealed that most of the institutions in New England and New York have written protocols for low-volume, high-risk, emergency events but few of these centers formally practice these protocols through simulation. We hypothesized that hands-on experience with medical emergency protocols will significantly improve clinician performance. Two groups (n = 24 each) of third semester perfusion students with comparable clinical skills were enrolled in this study. The first group was surprised with an emergent oxygenator change-out drill during a simulation exercise, with no prior warning and without the benefit of a written protocol. The second group was asked to develop a written protocol before they were challenged with the change-out drill. Subsequently, both groups were given a week to practice a protocol for emergent change-out before re-testing. The times for all change-out drills were recorded and the groups were compared with a Student's t-test. A p-value < 0.05 was considered significant. The group without a written protocol (NP) had the longer time (559.7 ± 84.9 sec) while the group with the written protocol (P) performed better (461.8 ± 57.5 sec, p < 0.05). However, both groups achieved significantly better performance following repeated practice (NP = 167.8 ± 34.8; P = 170.9±32.5 sec, p < 0 .05). While written protocols for emergent events will improve patient care, simulation and practice of emergency protocols is the most significant way to protect our patients. Based on this, we advocate for all perfusion groups to simulate emergency events and practice their crisis protocols.
ACCESSION #
51887429

 

Related Articles

  • Commentary on: Oxygenator change-out times: the value of a written protocol and simulation exercises. Darling, Edward // Perfusion;May2010, Vol. 25 Issue 3, p144 

    The article presents a discussion on the paper related to the value of a written protocol and simulation exercises on the use of oxygenator presented at the 30th Annual Seminar of the American Academy of Cardiovascular Perfusion. One discussant, Robert Groom, mentions the importance of declaring...

  • The relative safety of an oxygenator. Svenmarker, S.; Haggmark, S.; Jansson, E.; Lindholm, R.; Appelblad, M.; Aberg, T. // Perfusion;1997, Vol. 12 Issue 5, p289 

    Analysis of prospectively registered incidents related to cardiopulmonary bypass (CPB) was initiated to establish the incident rate for 10 different oxygenator brands employed over a seven-year period in 5000 clinical perfusions. A general safety index (SI) was defined as the number of recorded...

  • Editorial. Taylor, K. // Perfusion;1998, Vol. 13 Issue 3, p155 

    Editorial. Discusses on the ability of membrane oxygenators to handle and remove air. Quantification and localization of the air removal characteristics of membrane oxygenators; Analysis on the design and manufacture of cardiopulmonary bypass circuit components for neonatal and pediatric...

  • The incidence and cause of emergency oxygenator changeovers. Fisher, A.R. // Perfusion;1999, Vol. 14 Issue 3, p207 

    Emergency oxygenator changeover presents as an important potential hazard during cardiopulmonary bypass. In order to assess the frequency and possible causes of this event a retrospective survey was conducted of cardiothoracic units in the UK and Ireland. The survey was sent to these units in...

  • Cryofibrination: did it really happen? Luckraz, H.; Boolauky, D.; Mohangee, A. // Perfusion;Jan2001, Vol. 16 Issue 1, p83 

    Cryofibrin precipitation is a phenomenon which has only recently been described, although it might have been present since the advent of membraneoxygenators for cardiopulmonary bypass procedures. The deposition of the cold-reactive protein, cryofibrin, causes progressive occlusion of the...

  • Parallel replacement of the oxygenator that is not transferring oxygen: the PRONTO procedure. Groom, R. C.; Forest, R. J.; Cormack, J. E.; Niimi, K. S.; Morton, J. // Perfusion;Nov2002, Vol. 17 Issue 6, p447 

    We present here a technique to replace a failed oxygenator by inserting a second oxygenator in parallel (PRONTO) within the cardiopulmonary bypass (CPB) circuit. Oxygenator failure is a potential hazard that may result in patient injury or death. Although failures are rare, safety surveys...

  • practice makes PERFECT.  // BusinessWest;12/19/2011 Supplement, p1 

    The article focuses on the in situ labor and delivery simulation of a 28-year-old woman at the Baystate Medical Center, which aims to improve teamwork, communication, and crisis management skills for nearly 235 health care professionals.

  • Can an oxygenator design potentially contribute to air embolism in cardiopulmonary bypass? A novel method for the determination of the air removal capabilities of neonatal membrane oxygenators. de Somer, F.; Dierickx, P.; Dujardin, D.; Verdonck, P.; Nooten, G.V. // Perfusion;1998, Vol. 13 Issue 3, p157 

    At present, air handling of a membrane oxygenator is generally studied by using an ultrasonic sound bubble counter. However, this is not a quantitative method and it does not give any information on where air was entrapped in the oxygenator and if it eventually was removed through the membrane...

  • Oxygenator thrombosis: an international phenomenon. Schaadt, J. // Perfusion;1999, Vol. 14 Issue 6, p425 

    Oxygenator thrombosis, despite adequate anticoagulation, has become a recent concern amongst perfusionists worldwide. The phenomenon is characterized by a transient increase in oxygenator inlet pressure of up to 900 mmHg about 10-15 min after the institution of cardiopulmonary bypass (CPB)....