The historical building stock and seismic risk of Anatolia draws considerable attention of the engineers for studying the construction techniques and the earthquake performance of these structures. This study is dealing with the 145 years old Beylerbeyi palace. Within the study architectural features and the construction technique of the palace are introduced and the existing condition of the structure is investigated. The observed damages are classified and the possible sources of these damages are discussed. The final stage is the chemical analyses, performed over the mortar of the structure. Thin section analyses, Scanning Electro microscope analyses, Energy Dispersive X Ray Analyses and X-Ray Diffraction Analyses have been applied over ruins of Beylerbeyi Palace. The results of the analyses have been used to determine the origin of the mortar.
ACCESSION #
51839123

 

Related Articles

  • Using ED"P"XRF to analyze ceramic materials.  // Ceramic Industry;Dec97, Vol. 147 Issue 13, p46 

    Explores the analysis of ceramics by EDPXRF, a form of energy-dispersive x-ray fluorescence spectrometry (EDXRF) that uses polarized x-ray excitation to lower background levels and improve low-level analyses. Specifications of the Spectro X-Lab 2000 EDPXRF instrument; Sample preparation;...

  • X-ray fluorescence analysis of the systems Fe-Ni-Mo/Cr. Mashin, N.; Leont'eva, A.; Tumanova, A.; Lebedeva, R.; Ershov, A. // Journal of Analytical Chemistry;Feb2011, Vol. 66 Issue 2, p179 

    procedure has been developed for the X-ray fluorescence determination of the thickness of Fe-No-Mo/Cr two-layer films supported on polycor. Correction coefficients have been calculated that take into account the effects of the mutual influence of the elements in this system. The density of the...

  • Approaches to improving the accuracy in X-ray fluorescence analysis of Si1 − xGe x films. Mashin, N. I.; Leont'eva, A. A.; Lebedeva, R. V.; Tumanova, A. N. // Inorganic Materials;Mar2010, Vol. 46 Issue 3, p310 

    This work examines approaches to improving the accuracy in the X-ray fluorescence determination of the composition and thickness of thin Si1 − xGe x films on Polikor alumina substrates. We calculate correction coefficients that take into account the interelement effects in the films and...

  • The Formation of Analytical and Background Signals in Radioisotope X-ray Fluorescence Analysis Using a 241Am Radioactive Source and a Si(Li) Detector. Portnoi, A. Yu.; Pavlinskii, G. V.; Dukhanin, A. Yu.; Zuzaan, P.; Erdemchimeg, B. // Journal of Analytical Chemistry;Nov2004, Vol. 59 Issue 11, p1057 

    Reasons for the appearance of a background signal in the relatively soft x-ray range (2–15 keV) upon fluorescence excitation with the 241Am radioisotope are discussed. Mathematical models are proposed for the interaction of the radiation of the radioactive source with the sample and the...

  • X-ray Fluorescence Determination of Sulfur and Metals in Oil and Oil Products.  // Journal of Analytical Chemistry;Nov2004, Vol. 59 Issue 11, p1013 

    Focuses on the use of X-ray fluorescence analysis in determining sulfur and metals in oil and oil products. Demand for the rapid determination of sulfur and some other elements in both oil itself and its products; Versions of X-ray fluorescence analysis; Applications of X-ray fluorescence...

  • Determining analyte concentrations in plutonium metal by x-ray fluorescence using a dried residue method. Worley, Christopher G.; Havrilla, George J. // AIP Conference Proceedings;2000, Vol. 532 Issue 1, p334 

    Accurately determining the concentration of certain elements in plutonium is of vital importance in manufacturing nuclear weapons. X-ray fluorescence (XRF) provides a means of obtaining this type of elemental information accurately, quickly, with high precision, and often with little sample...

  • Three-dimensional chemical analysis of tungsten probes by energy dispersive x-ray nanotomography. Saghi, Z.; Xu, X.; Peng, Y.; Inkson, B.; Möbus, G. // Applied Physics Letters;12/17/2007, Vol. 91 Issue 25, p251906 

    The chemical distribution of oxide layers around functional tungsten nanotips is studied using electron tomography. Three-dimensional element distribution functions are derived for such tips, giving insight into the subsurface chemistry. Energy dispersive x-ray (EDX) spectroscopy is coupled to...

  • Composition study of CoPt bimetallic nanocrystals of 2 nm. Demortière, Arnaud; Losno, Rémi; Petit, Christophe; Quisefit, Jean-Paul // Analytical & Bioanalytical Chemistry;Jun2010, Vol. 397 Issue 4, p1485 

    The synthesis of bimetallic alloy nanocrystals with a well-controlled relative composition is a real challenge and requires chemical analysis techniques with high accuracy. A new chemical route has been used to synthesize cobalt–platinum nanocrystals of 2-nm diameter in a wide range of...

  • Phase diagram and oxygen stoichiometry of Y-Ba-Cu-O thin films. Yang, K. Y.; Homma, H.; Lee, R.; Bhadra, R.; Grimsditch, M.; Bader, S. D.; Locquet, J. P.; Bruynseraede, Y.; Schuller, Ivan K. // Applied Physics Letters;8/29/1988, Vol. 53 Issue 9, p808 

    We have performed an exhaustive study of the phase diagram of Y-Ba-Cu-O thin films using chemical analysis, energy dispersive x-ray spectroscopy, Auger electron spectroscopy, and x-ray diffraction. We show that Raman scattering can provide information regarding impurity phases and oxygen...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics