TITLE

The Role of Follow-up Radiographic Studies in Nonoperative Management of Spleen Trauma

AUTHOR(S)
Uecker, John; Pickett, Creighton; Dunn, Ernest
PUB. DATE
January 2001
SOURCE
American Surgeon;Jan2001, Vol. 67 Issue 1, p22
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The management of splenic injuries has evolved significantly in recent years from an operative to a nonoperative approach in stable patients with blunt abdominal trauma. The management of these patients with serial radiographic studies before hospital discharge remains controversial. We reviewed the management of 90 patients retrospectively who were admitted to our Level II trauma center with splenic injuries secondary to blunt trauma to determine the value of serial radiographic studies. Forty-seven (52%) patients underwent immediate laparotomy. Forty-three (48%) patients were managed conservatively without surgery. All nonoperative patients had an initial CT of the abdomen to evaluate their abdominal injuries. Among the 43 patients managed without surgery 31 had no follow-up radiographic studies. Twelve patients had follow-up studies before discharge. Two of these 12 patients subsequently underwent splenectomy. Both had developed hypotension, tachycardia, and a decreasing hematocrit, which prompted their repeat radiographic studies. Ten patients had no change in their clinical status and showed no significant change in the radiographic injury pattern to the spleen. One patient who was initially managed nonoperatively became hemodynamically unstable with increasing abdominal pain and subsequently underwent splenectomy without follow-up radiographic studies. The remaining 30 patients who had no follow-up studies had no significant change in their clinical abdominal examinations and had no further complications from their splenic injuries. Routine follow-up radiographic evaluations are not necessary in the nonoperative management of stable patients with splenic injuries.
ACCESSION #
5177317

 

Related Articles

  • Less Invasive Hemodynamic Monitoring. Luks, Andrew M. // Critical Care Alert;Jun2010, Vol. 18 Issue 3, p21 

    The article presents information on hemodynamic monitoring devices including pulse contour cardiac output (PiCCO) catheter, FloTrac system and LiDCO Plus system.

  • Variation in haemodynamic monitoring for major surgery in European nations: secondary analysis of the EuSOS dataset. Ahmad, Tahania; Beilstein, Christian M.; Aldecoa, Cesar; Moreno, Rui P.; Molnár, Zsolt; Novak-Jankovic, Vesna; Hofer, Christoph K.; Sander, Michael; Rhodes, Andrew; Pearse, Rupert M. // Perioperative Medicine;9/24/2015, Vol. 4 Issue 1, p1 

    Background: The use of cardiac output monitoring may improve patient outcomes after major surgery. However, little is known about the use of this technology across nations. Methods: This is a secondary analysis of a previously published observational study. Patients aged 16 years and over...

  • Hemodynamic and Physiologic Monitoring of the Mechanically Ventilated Patient. Scott, J. Brady // AARC Times;Oct2014, Vol. 38 Issue 10, p12 

    The article discusses the importance of hemodynamic and physiologic monitoring of the mechanically ventilated patient in health care settings. An explanation is offered on the usefulness of different monitoring parameters including arterial blood pressure, central venous pressure, pulmonary...

  • Torticolisul congenital. Zamfir, A.; Bălănescu, M. // ORL.ro;2014, Vol. 7 Issue 22, p12 

    Congenital torticollis is relatively uncommon in pediatric ENT practice. The neck complexity imposes particular protocols to investigate and diagnose the region. Searching for other malformations as well avoids further morbidity. Therapeutic approach involves different techniques and involve...

  • 727 Monitoring hemodynamics in patients with low cardiac output treated with extracorporeal membrane oxygenation (ECMO) using transesophageal echo- Doppler (ED). Garbade, J.; Barten, M.J.; Walther, T.; Krakor, R.; Gummert, J.F.; Mohr, F.W. // European Journal of Heart Failure. Supplements;Jun2004, Vol. 2 Issue 1, p153 

    An abstract of the study "Monitoring Hemodynamics in Patients With Low Cardiac Output Treated With Extracorporeal Membrane Oxygenation (ECMO) Using Transesophageal Echo-Doppler (ED)," by J. Garbade and colleagues is presented.

  • CE mark for Nexfin line.  // Medical Device Daily;7/25/2007, Vol. 11 Issue 140, p8 

    The article reports on the CE-mark approval received by Netherlands-based BMEYE for its Nexfin line of hemodynamic monitors. It says that these monitors provide the function of continuous non-invasive blood pressure and cardiac output monitoring. A finger sensor is being used by this family of...

  • Performance of a minimally invasive uncalibrated cardiac output monitoring system (FlotracTM/VigileoTM) in haemodynamically unstable patients. F. D. Compton; B. Zukunft; C. Hoffmann; W. Zidek; J.-H. Schaefer // BJA: The British Journal of Anaesthesia;Apr2008, Vol. 100 Issue 4, p451 

    Background Early haemodynamic assessment is of particular importance in the evaluation of haemodynamically compromised patients, but is often precluded by the invasiveness and complexity of the established cardiac output (CO) monitoring techniques. The FloTracâ„¢/Vigileoâ„¢ system allows...

  • Toward Intelligent Hemodynamic Monitoring: A Functional Approach. Squara, Pierre; Waldmann, Carl // Cardiology Research & Practice;2012, p1 

    Technology is now available to allow a complete haemodynamic analysis; however this is only used in a small proportion of patients and seems to occur when the medical staff have the time and inclination. As a result of this, significant delays occur between an event, its diagnosis and therefore,...

  • Positive End Expiratory Pressure Prevents Loss Of Respiratory Compliance During Low Tidal Volume Ventilation In Acute Lung Injury Patients. Gupta, Vishal; Gupta, Ajay; Mehta, Anjali; Wakloo, Renu; Angral, Rajesh; Sarswat, Vikas; Darswal, Poonam; Lahori, Rohit; Kapoor, B. B.; Gupta, Satyadev; Kumar, Dinesh // Internet Journal of Anesthesiology;2009, Vol. 20 Issue 2, p17 

    A total of 120 patients were enrolled in the present study over a period of 3 years from (2005 - 2008) . Pressure controlled ventilation (PCV) and volume controlled ventilation (VCV), with an average tidal Volume (VT) of 8.2 ű 0.4 ml/kg was applied at three levels of PEEP [5][10][15] cm...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics