TITLE

Increasing financial burden of revision total knee arthroplasty

AUTHOR(S)
Oduwole, Kayode O.; Molony, Diarmuid C.; Walls, Ray J.; Bashir, Simi P.; Mulhall, Kevin J.
PUB. DATE
July 2010
SOURCE
Knee Surgery, Sports Traumatology, Arthroscopy;Jul2010, Vol. 18 Issue 7, p945
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We reviewed the peri-operative and financial data of patients who underwent revision total knee arthroplasty in our institution between 1997 and 2006. The aims were to compare difference in cost between aseptic and septic cases and to identify the sources of preventable cost increase in revision knee procedure. The study group comprised 117 women (65%) and 62 men (35%). The median age of patients decreased from 73 years (37–83 years) in 1997–2001 to 70 years (15–91 years) in 2002–2006, a decline of 4% ( P < 0.05). The mean ASA scores also dropped from 3 to 2 between the two periods. Despite this, the mean total cost of revision knee procedure continued to increase. Patients undergoing revision arthroplasty because of infection had much higher ( P = 0.0001) cost compared to their aseptic counterpart. Increase in the costs of investigations ( P < 0.05) and implant ( P < 0.05) was the major contributing factors. The cost of implants increased by 32–35% ( P < 0.05) depending on implant selection. Changing demographics will increase the requirement for this surgery and thus increase its overall cost to society. Cost increases associated with unnecessary investigations, prolonged hospital stay and use of expensive implants should be avoided.
ACCESSION #
51517235

 

Related Articles

  • Two-stage total infected knee arthroplasty treatment with articulating cement spacer. Ocguder, Ali; Firat, Ahmet; Tecimel, Osman; Solak, Sukru; Bozkurt, Murat // Archives of Orthopaedic & Trauma Surgery;Jun2010, Vol. 130 Issue 6, p719 

    The treatment of infected total knee arthroplasty (TKA) is controversial and various. Two-stage prolonged reimplantation and 6-week systemic antibiotics use have been a gold standard of treatment in recent years. Seventeen knees of 17 patients, who underwent primary TKA and subsequently...

  • Primary total knee arthroplasty using rotating-hinge prosthesis in severely affected knees. Yang, Jae-Hyuk; Yoon, Jung-Ro; Oh, Chi-Hun; Kim, Taik-Sun // Knee Surgery, Sports Traumatology, Arthroscopy;Mar2012, Vol. 20 Issue 3, p517 

    Purpose: A rotating-hinge total knee prosthesis may be utilized for the treatment of global instability or severe bone loss around the knee. The outcome of primary total knee arthroplasty (TKA) using Endo-Modell (Link) rotating-hinge prosthesis was evaluated. Methods: Retrospectively, review of...

  • Fracture at the stem-condylar junction of a modular femoral prosthesis in a varus-valgus constrained total knee arthroplasty. Nikolopoulos, D.; Polyzois, I.; Magnissalis, E.; Bernard, P.; Michos, I. // Knee Surgery, Sports Traumatology, Arthroscopy;Jun2012, Vol. 20 Issue 6, p1071 

    We present a rare case of fracture of the modular femoral component in a varus-valgus constrained total knee arthroplasty (TKA) prosthesis which occurred 2 years after implantation. Both femoral and tibial components underwent a second revision using a constrained hinged TKA. Laboratory analysis...

  • Increased flexion position of the femoral component reduces the flexion gap in total knee arthroplasty. Matziolis, Georg; Hube, Robert; Perka, Carsten; Matziolis, Doerte // Knee Surgery, Sports Traumatology, Arthroscopy;Jun2012, Vol. 20 Issue 6, p1092 

    Background: The symmetry and equality of the flexion and extension gap are essential for successful endoprosthetic knee arthroplasty. Cruciate ligament sparing endoprosthetic designs are implanted with a measured resection technique, so that the posterior bone resection corresponds to the...

  • Most patients should expect TKR implants to activate airport security systems. Rapp, Susan M. // Orthopaedics Today Europe;Jul/Aug2008, Vol. 11 Issue 4, p7 

    The article focuses on a study which revealed that patients with total knee replacements are more likely to set off walk-through airport security scanners because of the metal in their implants. Investigators discovered that 90% of patients experienced their implants setting off walk-through...

  • 'Spin-out' - eine vermeidbare Komplikation in der Knieendoprothetik. Magin, M.N. // Der Orthopäde;Feb2014, Vol. 43 Issue 2, p175 

    Spin out of a rotating polyethylene (PE) platform after total knee replacement leads to rotation of the bearing compared to the fixed metal components of the prosthesis at the femur and tibia of approximately 90°. This complication occurs only in prosthesis designs which do not have a...

  • An alternative method to create extramedullary references in total knee arthroplasty. Seo, Jai-Gon; Moon, Young-Wan; Park, Sang-Hoon; Shim, Jae-Woo; Kim, Sang-Min // Knee Surgery, Sports Traumatology, Arthroscopy;Jul2012, Vol. 20 Issue 7, p1339 

    Purpose: Historically, extramedullary techniques have focused on finding the femoral head center and referred mainly to the anterosuperior iliac spine (the FHC method) in total knee arthroplasty (TKA). The purpose of this study was to evaluate a new extramedullary alignment system that uses...

  • Assessing patient-oriented results after revision total knee arthroplasty. Baier, Clemens; Lüring, Christian; Schaumburger, Jens; Köck, Franz; Beckmann, Johannes; Tingart, Markus; Zeman, Florian; Grifka, Joachim; Springorum, Hans-Robert // Journal of Orthopaedic Science;Nov2013, Vol. 18 Issue 6, p955 

    Background: Revision total knee arthroplasties (TKA) have been performed with increasing frequency over the last 25 years. Methods: In this study, we retrospectively analyzed 78 patients who underwent 78 revision TKAs during the years 2003–2007 with an average follow-up of 81 months...

  • Effect of bioactive coating of the tibial component on migration pattern in uncemented total knee arthroplasty: a randomized RSA study of 14 knees presented according to new RSA-guidelines. M. Therbo; B. Lund; K.-E. Jensen; H. Schrøder // Journal of Orthopaedics & Traumatology;Jun2008, Vol. 9 Issue 2, p63 

    Abstract Background  Bioactive coating of uncemented total knee arthroplasty (TKA) is believed to increase bone ingrowth and enhance early fixation of the TKA. In a prospective randomized study using radiostereometric analysis (RSA) we examined migrations of the tibial implant, in an...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics