TITLE

Redefining cooling tower performance

PUB. DATE
June 2010
SOURCE
DEMM: Engineering & Manufacturing;Jun2010, p16
SOURCE TYPE
Trade Publication
DOC. TYPE
Article
ABSTRACT
The article focuses on the advantages of using the Baldor Reliance RPM AC Cooling Tower Direct Drive Motor with a Permanent Magnet Rotor (PMR) design for Tower Engineering. Among the inherent problems encountered by the firm from gearboxes were misalignment, excessive vibration and noise. Benefits of the Cooling Tower include high system energy efficiency, variable speed and optimum performance. The technology is expected to eliminate troublesome gearbox maintenance issues and to transform the traditional cooling tower fan motor to a green solution.
ACCESSION #
51433288

 

Related Articles

  • Direct-Drive Cooling Tower Technology Improves System Efficiencies. Wajda, Roman // Electroindustry;Aug2015, Vol. 20 Issue 8, p13 

    The article offers information on the permanent magnet (PM )/ laminated frame motor technology used in air-cooled condensers and heat exchangers, and also mentions the advantages of cooling towerpermanent magnet (CTPM) motor.

  • Ceramic fill cooling tower provides efficient, durable air conditioning at university.  // American Ceramic Society Bulletin;May2010, Vol. 89 Issue 4, p13 

    The article offers information on the ceramic water-cooling tower installed at the Armstrong State University (AASU) in Savannah, Georgia. It discusses that the cooling tower, installed by Tower Engineering Inc., provides basic technology that will provide lifetime heating, ventilation, and air...

  • Comparison of Torque Density for Three Phase Double Sided Slot-less AFPM Motors. Gholamian, S. Asghar // Global Journal of Pure & Applied Mathematics;2011, Vol. 7 Issue 2, p147 

    Selecting an AFPM motors with high torque densities an important parameter in applications. So, comparison of torque density between different topologies of double-sided AFPM motors seems to be necessary. In this paper, the sizing equations of axial flux slot-less one-stator-two-rotor (TORUS)...

  • Effect of Air Gap on Power Density for Various Types of Double-Sided Axial Flux Slotted PM Motors using Analytic and FEM Evaluation. Gholamian, S. A.; Ardebili, M.; Abbaszadeh, K. // European Journal of Scientific Research;May2008, Vol. 20 Issue 3, p470 

    Double-sided axial flux PM motors (AFPM) are the most promising and widely used types. There are two topologies for slotted double-sided AFPM motors. Selecting an AFPM motors with high power density is an important parameter in applications. So, comparison of power density between different...

  • Speed Control of Brushless DC Motor Using Fuzzy Controller. Puttalakshmi, G. R.; Paramasivam, S. // IUP Journal of Electrical & Electronics Engineering;Jan2014, Vol. 7 Issue 1, p7 

    The paper presents a control scheme of a fuzzy logic for the Brushless Direct Current (BLDC) permanent magnet motor drives. The mathematical model of BLDC motor and fuzzy logic algorithm is derived. The controller is designed to track variations of speed references and stabilizes the output...

  • Additional Torque in Multipole Permanent Magnet Machines Caused by Eccentricity. Shevchenko, Aleksandr Fedorovich; Toporkov, Dmitrii Michailovich // Applied Mechanics & Materials;2015, Vol. 792, p78 

    The additional torque caused by the static eccentricity in multipole permanent magnet machines is investigated in the paper. The equation governing the dependence of the additional torque on number of poles and the amount of eccentricity qualitatively is developed. Analytical conclusions are...

  • Performance Analysis of a Surface Permanent Magnet Motor. PETKOVSKA, Lidija; CVETKOVSKI, Goga // Przeglad Elektrotechniczny;2016, Vol. 92 Issue 12, p133 

    In the paper the Finite Element Method (FEM) to analyse the performance characteristics of a surface permanent magnet motor is employed. The object of study is a permanent magnet motor with surface permanent magnets. Two rotor topologies are considered: surface- mounted (SM) and surface-inset...

  • Design of Full Order Observer for VSI Fed PMSM Drive. Ramana, P.; Kumar, M. Phani; Mary, K. A.; Kalavathi, M. S. // International Journal of Emerging Sciences;Sep2011, Vol. 1 Issue 3, p504 

    This paper presents the PMSM mathematical model based on the rotor reference frame. The state feedback control for a Permanent Magnet Motor requires the knowledge of all states. In this paper we are estimating all the states of PMSM, both accessible and inaccessible by using full order observer,...

  • Motors and Drives.  // Air Conditioning Heating & Refrigeration News;3/13/2006, Vol. 227 Issue 11, p8 

    The article presents the EcoHeart's high-efficiency permanent magnet motors and drives with a permanent magnet technology that attains 10 percent higher efficiency. An advanced sinusoidal motor current wave form allows the units to achieve low torque ripple, low vibration and acoustic noise, and...