TITLE

Paper-based microfluidic devices for analysis of clinically relevant analytes present in urine and saliva

AUTHOR(S)
Klasner, Scott A.; Price, Alexander K.; Hoeman, Kurt W.; Wilson, Rashaun S.; Bell, Kayla J.; Culbertson, Christopher T.
PUB. DATE
July 2010
SOURCE
Analytical & Bioanalytical Chemistry;Jul2010, Vol. 397 Issue 5, p1821
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We report the use of paper-based microfluidic devices fabricated from a novel polymer blend for the monitoring of urinary ketones, glucose, and salivary nitrite. Paper-based devices were fabricated via photolithography in less than 3 min and were immediately ready for use for these diagnostically relevant assays. Patterned channels on filter paper as small as 90 μm wide with barriers as narrow as 250 μm could be reliably patterned to permit and block fluid wicking, respectively. Colorimetric assays for ketones and nitrite were adapted from the dipstick format to this paper microfluidic chip for the quantification of acetoacetate in artificial urine, as well as nitrite in artificial saliva. Glucose assays were based on those previously demonstrated (Martinez et al., Angew Chem Int Ed 8:1318–1320, ; Martinez et al., Anal Chem 10:3699–3707, ; Martinez et al., Proc Nat Acad Sci USA 50:19606–19611, ; Lu et al., Electrophoresis 9:1497–1500, ; Abe et al., Anal Chem 18:6928–6934, ). Reagents were spotted on the detection pad of the paper device and allowed to dry prior to spotting of samples. The ketone test was a two-step reaction requiring a derivitization step between the sample spotting pad and the detection pad, thus for the first time, confirming the ability of these paper devices to perform online multi-step chemical reactions. Following the spotting of the reagents and sample solution onto the paper device and subsequent drying, color images of the paper chips were recorded using a flatbed scanner, and images were converted to CMYK format in Adobe Photoshop CS4 where the intensity of the color change was quantified using the same software. The limit of detection (LOD) for acetoacetate in artificial urine was 0.5 mM, while the LOD for salivary nitrite was 5 μM, placing both of these analytes within the clinically relevant range for these assays. Calibration curves for urinary ketone (5 to 16 mM) and salivary nitrite (5 to 2,000 μM) were generated. The time of device fabrication to the time of test results was about 25 min. [Figure not available: see fulltext.]
ACCESSION #
51411060

 

Related Articles

  • Researchers build 3-D fluidic device to 'sort' nanomaterials. LONG, DON // Medical Device Daily;4/16/2009, Vol. 13 Issue 72, p1 

    The article focuses on a new three-dimensional (3-D) nanofluidic device developed by researchers at the National Institute of Standards and Technology (NIST) and Cornell University. The key driver for the development of the device is the need to determine the differentiating characteristics of...

  • Testing device 'finds optimal growth conditions for oil algae'.  // Engineer (Online Edition);9/17/2012, p9 

    The article discusses a technology developed by a team from Texas A&M University, Texas that allows researchers to trail different growth conditions at once to see which conditions are best for producing large amounts of algae that give a high oil yield. The device, invented by Dr. Arum Han,...

  • Sticky Lithography. WILLIAMS, RUTH // Scientist;Mar2013, Vol. 27 Issue 3, p31 

    The article offers step-by-step instructions for using a photolithographic equipment which is used in microfluidic devices for depositing cells onto specific parts of culture dishes and slides.

  • MFSI awarded U.S. patent for microfluidic valve mechanism.  // Medical Device Daily;11/17/2009, Vol. 13 Issue 222, p9 

    This article reports on a U.S. patent received by Microfluidic Systems for microfluidic valve mechanism in 2009. Microfluidic Systems said the patent covers a set of claims about the integration of a diaphragm membrane into a rigid body of a cartridge. The company added that the patent offers a...

  • Optically Induced Thermal Gradients for Protein Characterization in Nanolitre-scale Samples in Microfluidic Devices. Sagar, D. M.; Aoudjane, Samir; Gaudet, Matthieu; Aeppli, Gabriel; Dalby, Paul A. // Scientific Reports;7/5/2013, p1 

    Proteins are the most vital biological functional units in every living cell. Measurement of protein stability is central to understanding their structure, function and role in diseases. While proteins are also sought as therapeutic agents, they can cause diseases by misfolding and aggregation...

  • Lab-on-a-brain: Implantable micro-optical fluidic devices for neural cell analysis in vivo. Takehara, Hiroaki; Nagaoka, Akira; Noguchi, Jun; Akagi, Takanori; Kasai, Haruo; Ichiki, Takanori // Scientific Reports;10/24/2014, p1 

    The high-resolution imaging of neural cells in vivo has brought about great progress in neuroscience research. Here, we report a novel experimental platform, where the intact brain of a living mouse can be studied with the aid of a surgically implanted micro-optical fluidic device; acting as an...

  • An electric stimulation system for electrokinetic particle manipulation in microfluidic devices. Lopez-de la Fuente, M. S.; Moncada-Hernandez, H.; Perez-Gonzalez, V. H.; Lapizco-Encinas, B. H.; Martinez-Chapa, S. O. // Review of Scientific Instruments;Mar2013, Vol. 84 Issue 3, p035103 

    Microfluidic devices have grown significantly in the number of applications. Microfabrication techniques have evolved considerably; however, electric stimulation systems for microdevices have not advanced at the same pace. Electric stimulation of micro-fluidic devices is an important element in...

  • Paper-Based Microfluidic Device for Determination of Nitrite in Pickled Vegetables. CHUNXIU XU; MINGHUA ZHONG; YUNYING WU; LONGFEI CAI; JIANI HONG; YUNA HUANG // Asian Journal of Chemistry;2014, Vol. 26 Issue 14, p4330 

    Nitrite is a carcinogen which has been detected in various foods including pickled vegetables, cured meat and fish products. Development of cost effective, simple and easy-to- use method for determination of nitrite in foods is thus highly desirable, especially for those foods that traditionally...

  • Fluidigm Delivers More Than One Bln Microscopic NanoFlex(tm) Valves.  // Biomedical Market Newsletter;5/9/2011, p289 

    The article reports that Fluidigm Corp., provider of microfluidic valves for Life Sciences has announced that its Singapore factory has manufactured and shipped more than 1 bln microscopic NanoFlex(tm) valves. Each NanoFlex valve is so small that it takes 10 to span the width of a human hair....

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.