ABSTRACT
Background: Talar osteochondral defects can lead to joint degeneration. Focal resurfacing with a metallic implant has shown promise in other joints. We studied the effect of implantation accuracy on ankle contact mechanics after focal resurfacing of a defect in the talar dome. Methods: Static loading of seven cadaver ankles was performed before and after creation of a 15–mm–diameter Osteochondral defect on the talar dome, and joint contact stresses were measured. The defect was then resurfaced with a metallic implant, with use of a custom implant–bone interface fixture that allowed fine control (in 0.25–mm steps) of implantation height. Stress measurements were repeated at heights of –0.5 to +0.5 mm relative to an as–implanted reference. Finite element analysis was used to determine the effect of implant height, post axis rotation, and valgus/ varus tilt over a motion duty cycle. Results: With the untreated defect, there was a 20% reduction in contact area and a 40% increase in peak contact stress, as well as a shift in the location of the most highly loaded region, as compared with the values in the intact condition. Resurfacing led to recovery of 90% of the contact area that had been measured in the intact specimen, but the peak contact stresses remained elevated. With the implant 0.25 mm proud, peak contact stress was 220% of that in the intact specimen. The results of the finite element analyses agreed closely with those of the experiments and additionally showed substantial variations in defect influences on contact stresses across the motion arc. Talar internal/external rotations also differed for the unfilled defect. Focal implant resurfacing substantially restored kinematics but did not restore the stresses to the levels in the intact specimens. Conclusions: Focal resurfacing with a metallic implant appears to have the potential to restore normal joint mechanics in ankles with a large talar osteochondral defect. However, contact stresses were found to be highly sensitive to implant positioning. Clinical Relevance: Resurfacing a talar osteochondral defect with an implant that restores the joint contour, that provides immediate stability, and that reproduces normal joint mechanics, without requiring biological potential, offers advantages over existing resurfacing techniques; however, restoration of normal joint mechanics is highly dependent on precise surgical implantation.
ACCESSION #
51404003

 

Related Articles

  • Comparison of various surgical methods in the treatment of implant-related infection. Şener, Muhittin; Kazimoglu, Cemal; Karapınar, Hasan; Günal, İzge; Afşar, İlhan; Karataş Şener, Aslı // International Orthopaedics;Mar2010, Vol. 34 Issue 3, p419 

    The treatment of implant-related infections is troublesome. This study was conducted to compare the effectiveness of three different surgical modalities in the treatment of implant-related infection. A total of 32 Wistar albino rats were randomised into four groups after the establishment of...

  • Extracortical Bone Bridging in Tumor Endoprostheses. Tanzer, Michael; Turcotte, Robert; Harvey, Edward; Bobyn, J. Dennis // Journal of Bone & Joint Surgery, American Volume;Dec2003, Vol. 85-A Issue 12, p2365 

    Aseptic loosening remains a major problem following prosthetic replacement after resection of periarticular tumors. Attempts to decrease the rate of loosening led to the introduction of a composite segmental prosthesis in which the shoulder of the intramedullary stem is porous-coated to allow...

  • Knöchelosteotomie - Die Osteotomie als Zugang. Barg, A.; Pagenstert, G.; Leumann, A.; Valderrabano, V. // Der Orthopäde;May2013, Vol. 42 Issue 5, p309 

    Both arthroscopic and open surgical techniques may be used for treatment of osteochondral lesions of the ankle joint. Osteotomy around the ankle joint is a well established technique to extend the approach in cases where the osteochondral lesions are located more posteriorly. Medial, oblique,...

  • Focus on malleolar fractures. Heim, D. // European Journal of Trauma & Emergency Surgery;Dec2010, Vol. 36 Issue 6, p503 

    The author reflects on the treatment for ankle fractures. He mentions that ankle fractures is considered as the most common fracture in human skeleton. It states that the application of weight-bearing radiographs for assessing ankle fractures stability can be a help in determining the indication...

  • Management of Complications Associated with Totally Implantable Ports in Patients with AIDS. Domingo, Pere; Fontanet, Angels // AIDS Patient Care & STDs;Jan2001, Vol. 15 Issue 1, p7 

    Morbidity associated with totally implantable ports is common in patients with acquired immune deficiency syndrome (AIDS). More than half of the implanted devices will have at least one complication before its removal or the patient's death. Infectious complications are the most frequent. Two...

  • Application of autologous bone fresh-frozen and re-implantation in treatment of cranio-maxillofacial bone tumors: report of 4 cases. CHEN Shun-ye; LIU Zhi-hui; LU Yu; HU Yong-jie // Shanghai Journal of Stomatology;Oct2008, Vol. 17 Issue 5, p545 

    PURPOSE: To evaluate the application of autologous bone fresh-frozen and re-implantation in treatment of cranio-maxillofacial bone tumors. METHODS: Four cases with cranio-maxillofacial bone tumors, including one in the frontal bone and three in the mandible, underwent osteoectomy, autologous...

  • Megapfannen und Beckenteilersatz. Eisenhart-Rothe, R.; Gollwitzer, H.; Toepfer, A.; Pilge, H.; Holzapfel, B.M.; Rechl, H.; Gradinger, R. // Der Orthopäde;Oct2010, Vol. 39 Issue 10, p931 

    Extensive bone loss, as encountered in both revision arthroplasty of the hip and after resection of malignant tumors of the pelvis, is a major challenge for the surgeon as well as for the revision implant. The aims are, despite extensive acetabular defects, to achieve a primary and load-stable...

  • Aplicación de xenoimplante para el tratamiento de defectos óseos, tumores benignos, seudoartrosis y artrodesis. (Reporte preliminar). Cueva Del Castillo, J. Fernando; Francisco Osuna, J.; Elizondo, F.; Pérez, O.; Pérez, A.; Hernández, Sergio; Mejía, Carlos // Acta Ortopedica Mexicana;ene/feb2007, Vol. 21 Issue 1, p31 

    Objective. To show that the ceramic produced at the Institute for Materials Research, National Autonomous University of Mexico, is an appropriate replacement of bone graft in patients with bone tumors, benign tumors, pseudoarthrosis and arthrodesis treated at «General Ignacio Zaragoza»...

  • Fixed-bearing TAR improves gait function. Stanton, Terry // AAOS Now;Sep2011, Vol. 5 Issue 9, p12 

    The article focuses on a study which assesses the gait mechanics in patients who underwent total ankle replacement (TAR) with fixed-bearing implants. It notes that the study examined two different fixed-bearing TAR implants in 51 patients. The study reveals that patients who received one of the...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics