TITLE

Hg stable isotope analysis by the double-spike method

AUTHOR(S)
Mead, Chris; Johnson, Thomas M.
PUB. DATE
June 2010
SOURCE
Analytical & Bioanalytical Chemistry;Jun2010, Vol. 397 Issue 4, p1529
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Recent publications suggest great potential for analysis of Hg stable isotope abundances to elucidate sources and/or chemical processes that control the environmental impact of mercury. We have developed a new MC-ICP-MS method for analysis of mercury isotope ratios using the double-spike approach, in which a solution containing enriched 196Hg and 204Hg is mixed with samples and provides a means to correct for instrumental mass bias and most isotopic fractionation that may occur during sample preparation and introduction into the instrument. Large amounts of isotopic fractionation induced by sample preparation and introduction into the instrument (e.g., by batch reactors) are corrected for. This may greatly enhance various Hg pre-concentration methods by correcting for minor fractionation that may occur during preparation and removing the need to demonstrate 100% recovery. Current precision, when ratios are normalized to the daily average, is 0.06‰, 0.06‰, 0.05‰, and 0.05‰ (2 σ) for 202Hg/198Hg, 201Hg/198Hg, 200Hg/198Hg, and 199Hg/198Hg, respectively. This is slightly better than previously published methods. Additionally, this precision was attained despite the presence of large amounts of other Hg isotopes (e.g., 5.0% atom percent 198Hg) in the spike solution; substantially better precision could be achieved if purer 196Hg were used.
ACCESSION #
50870516

 

Related Articles

  • Heavy element stable isotope ratios : analytical approaches and applications. Tanimizu, Masaharu; Sohrin, Yoshiki; Hirata, Takafumi // Analytical & Bioanalytical Chemistry;Mar2013, Vol. 405 Issue 9, p2771 

    Continuous developments in inorganic mass spectrometry techniques, including a combination of an inductively coupled plasma ion source and a magnetic sector-based mass spectrometer equipped with a multiple-collector array, have revolutionized the precision of isotope ratio measurements, and...

  • Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report). Brand, Willi A.; Coplen, Tyler B.; Vogl, Jochen; Rosner, Martin; Prohaska, Thomas // Pure & Applied Chemistry;Mar2014, Vol. 86 Issue 3, p425 

    Since the early 1950s, the number of international measurement standards for anchoring stable isotope delta scales has mushroomed from 3 to more than 30, expanding to more than 25 chemical elements. With the development of new instrumentation, along with new and improved measurement procedures...

  • Invited Review Article: Recent developments in isotope-ratio mass spectrometry for geochemistry and cosmochemistry. Ireland, Trevor R. // Review of Scientific Instruments;Jan2013, Vol. 84 Issue 1, p011101 

    Mass spectrometry is fundamental to measurements of isotope ratios for applications in isotope geochemistry, geochronology, and cosmochemistry. Magnetic-sector mass spectrometers are most common because these provide the best precision in isotope ratio measurements. Where the highest precision...

  • An introduction to mass cytometry: fundamentals and applications. Tanner, Scott; Baranov, Vladimir; Ornatsky, Olga; Bandura, Dmitry; George, Thaddeus // Cancer Immunology, Immunotherapy;May2013, Vol. 62 Issue 5, p955 

    Mass cytometry addresses the analytical challenges of polychromatic flow cytometry by using metal atoms as tags rather than fluorophores and atomic mass spectrometry as the detector rather than photon optics. The many available enriched stable isotopes of the transition elements can provide up...

  • Metal Content and Stable Isotope Determination in Some Commercial Beers from Romanian Markets. Voica, Cezara; Magdas, Dana-Alina; Feher, Ioana // Journal of Chemistry;5/26/2015, Vol. 2015, p1 

    Characterization of beer samples is of interest because their compositions affect the taste and stability of beer and, also, consumer health. In this work, the characterizations of 20 Romanian beers were performed by mean of Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and Isotope Ratio...

  • Application of non-traditional stable isotopes in analytical ecogeochemistry assessed by MC ICP-MS - A critical review. Irrgeher, Johanna; Prohaska, Thomas // Analytical & Bioanalytical Chemistry;Jan2016, Vol. 408 Issue 2, p369 

    Analytical ecogeochemistry is an evolving scientific field dedicated to the development of analytical methods and tools and their application to ecological questions. Traditional stable isotopic systems have been widely explored and have undergone continuous development during the last century....

  • MeCAT-new iodoacetamide reagents for metal labeling of proteins and peptides. Schwarz, Gunnar; Beck, Sebastian; Weller, Michael; Linscheid, Michael // Analytical & Bioanalytical Chemistry;Dec2011, Vol. 401 Issue 4, p1203 

    Besides protein identification via mass spectrometric methods, protein and peptide quantification has become more and more important in order to tackle biological questions. Methods like differential gel electrophoresis or enzyme-linked immunosorbent assays have been used to assess protein...

  • An in-depth evaluation of accuracy and precision in Hg isotopic analysis via pneumatic nebulization and cold vapor generation multi-collector ICP-mass spectrometry. Rua-Ibarz, Ana; Bolea-Fernandez, Eduardo; Vanhaecke, Frank // Analytical & Bioanalytical Chemistry;Jan2016, Vol. 408 Issue 2, p417 

    Mercury (Hg) isotopic analysis via multi-collector inductively coupled plasma (ICP)-mass spectrometry (MC-ICP-MS) can provide relevant biogeochemical information by revealing sources, pathways, and sinks of this highly toxic metal. In this work, the capabilities and limitations of two different...

  • Refining Kinetics of Selected Elements in the Industrial Silicon Process. Kero, Ida; Næss, Mari; Andersen, Vegar; Tranell, Gabriella // Metallurgical & Materials Transactions. Part B;Jun2015, Vol. 46 Issue 3, p1186 

    An industrial oxidative ladle refining process of metallurgical grade silicon has been experimentally examined. An extensive industrial sampling campaign has been performed and samples of silicon and slag have been analyzed by inductively coupled plasma mass spectroscopy (ICP-MS). The elemental...