Characterization of a capacitance-coupled contactless conductivity detection system with sidewall electrodes on a low-voltage-driven electrophoresis microchip

AUTHOR(S)
Yi Xu; Jing Liang; Haitao Liu; Xiaoguo Hu; Zhiyu Wen; Yongjie Wu; Mingxia Cao
PUB. DATE
June 2010
SOURCE
Analytical & Bioanalytical Chemistry;Jun2010, Vol. 397 Issue 4, p1583
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A new type of capacitance-coupled contactless conductivity detection (C4D) system with sidewall electrodes was proposed for integration on a silicon-on-isolator–poly(dimethylsiloxane) (SOI-PDMS) hybrid low-voltage-driven electrophoresis microchip. By a microelectromechanical system process, the sidewall electrodes were fabricated precisely at either side of the separation channel. The area of the capacitor electrodes was the maximum value to improve the detection sensitivity with an enhanced capacitance effect. According to the simulation results, the structural parameters of the sidewall electrodes were determined as 550-μm length, 15-μm width, 80-μm separation distance, and 1-μm isolator thickness. The integrated microdevice with the SOI-PDMS hybrid electrophoresis microchip was very compact and the size was only 15 cm × 15 cm × 10 cm (width × length × height), which permitted miniaturization and portability. The detector performance was evaluated by K+ testing. The detection limit of the conductivity detector was determined to be 10-9 and 10-6 M for K+ in the static and electric-driven modes, respectively. Finally, the C4D was applied to low-voltage-driven electrophoresis on a microchip to carry out real-time measurement of the separation of amino acids. The separations of 10-4 M lysine and phenylalanine in the low-voltage-driven electrophoresis mode were performed with an electric field of 300 V/cm and were completed in less than 15 min with a resolution of 1.3. The separation efficiency was found to be 1.3 × 103 and 2.8 × 103 plates for lysine and phenylalanine, respectively, with a migration time reproducibility of 2.7 and 3.2%. The conductivity detection limit of amino acids achieved was 10-6 M. The proposed method for the construction of a novel C4D integrated on an SOI-PDMS hybrid low-voltage-driven electrophoresis microchip showed the most extensive integration and miniaturization of a microdevice, which is a further crucial step toward the realization of the “lab-on-a-chip” concept.
ACCESSION #
50870505

 

Related Articles

  • A Small Signal Capacitance Model for A Metallic Electrochemical Electrode in the Charge Transfer Region. Alamoud, A.R.M. // Egyptian Journal of Solids;2000, Vol. 23 Issue 2, p203 

    In this paper a small signal capacitance model for an electrochemical electrode is developed. This model takes into consideration the conventional Helmholtz layer and diffusion layer capacitances in addition to the capacitance of a homogeneous middle layer between the two previous layers. The...

  • Capacitance measurement of semiconductor electrodes by means of the HP-4274A LCR meter. St. Popkirov, George // Review of Scientific Instruments;Jan1990, Vol. 61 Issue 1, p200 

    It is suggested how a Hewlett-Packard LCR meter HP4274A can easily be used for capacitancevoltage measurements of semiconductor electrodes in an electrochemical cell. Two measurement schemes are presented. In the first, the electrode potential of the sample is controlled by means of an...

  • Note: Microelectromechanical systems Coulter counter for cell monitoring and counting. Yifan Wu; Benson, James D.; Critser, John K.; Almasri, Mahmoud // Review of Scientific Instruments;Jul2010, Vol. 81 Issue 7, p076103 

    This note describes the design, fabrication, and testing of a novel microelectromechanical systems Coulter counter. The Coulter counter will be used to detect and monitor impedance changes of cells as a function of time in response to different experimental extracellular environments. The device...

  • Carbon nanotube film piezoresistors embedded in polymer membranes. Kangwon Lee; Lee, Seung S.; Lee, Jung A.; Kwang-Cheol Lee; Seungmuk Ji // Applied Physics Letters;1/4/2010, Vol. 96 Issue 1, p013511 

    We present carbon nanotube film (CNF) piezoresistors embedded in polymer membranes. CNFs by vacuum filtration are patterned on an Au-deposited Si-wafer and transferred onto the poly-dimethylsiloxane (PDMS) using the weak adhesion property between Au-layer and Si-wafer. Transmittance and I-V...

  • A microfluidic Coulter counting device for metal wear detection in lubrication oil. Murali, Srinidhi; Jagtiani, Ashish V.; Xia, Xingao; Carletta, Joan; Zhe, Jiang // Review of Scientific Instruments;Jan2009, Vol. 80 Issue 1, pN.PAG 

    We present the design, fabrication, and testing of a microfluidic device for metal wear detection in lubrication oils. The detection is based on the capacitance Coulter counting principle, that is, on the change in a microchannel’s capacitance caused by the presence of a metal particle in...

  • Methods for Measuring of Small Capacitance. Velev, Rosen Grigorov; Ivanov, Simeon Ivanov // Annual Journal of Electronics;2010, Vol. 4 Issue 1, p65 

    The article describes two methods for measuring of small capacitance. Two measurement systems are investigated by the authors, covering two different measurement principles. Both are experimented in real measuring capacitance of MEMS structures.

  • Análisis y caracterización de un acelerómetro capacitivo fabricado con tecnología polymump's. Rincon-Jara, R. I.; Ambrosio, R.; Mireles, J. // Superficies y Vacío;2010, Vol. 23 Issue 3, p26 

    This work presents the analysis and characterization of a capacitive accelerometer fabricated with PolyMUMP's technology. The structure contains a proof mass which is suspended between fixed rigid electrodes to sense differential capacitance measurement. The accelerometer structure was simulated...

  • Comment on “Comparison of air breakdown and substrate injection as mechanisms to induce dielectric charging in microelectromechanical switches” [Appl. Phys. Lett. 92, 043502 (2008)]. Olszewski, Zbigniew; O’Mahony, Conor; Houlihan, Ruth; Duane, Russell // Applied Physics Letters;10/26/2009, Vol. 95 Issue 17, p176101 

    The purpose of this comment is to provide additional insight into the reliability of microelectromechanical capacitive switches (MEMSs) investigated by Molinero and Castañer [Appl. Phys. Lett. 92, 043502 (2008)]. We show that the presence or absence of ambient humidity determines whether the...

  • Effects of dielectric charging on fundamental forces and reliability in capacitive microelectromechanical systems radio frequency switch contacts. Patton, Steven T.; Zabinski, Jeffrey S. // Journal of Applied Physics;5/1/2006, Vol. 99 Issue 9, p094910 

    Microelectromechanical systems (MEMS) radio frequency switches hold great promise in a myriad of commercial, aerospace, and military applications. In particular, capacitive-type switches with metal-to-dielectric contacts (typically gold-on-silicon nitride) are suitable for high frequency (>=10...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics