TITLE

Misalignment of Total Ankle Components Can Induce High Joint Contact Pressures

AUTHOR(S)
Espinosa, N.; Walti, M.; Favre, P.; Snedeker, J. G.
PUB. DATE
May 2010
SOURCE
Journal of Bone & Joint Surgery, American Volume;May2010, Vol. 92-A Issue 5, p1179
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: A major cause of the limited longevity of total ankle replacements is premature polyethylene component wear, which can be induced by high joint contact pressures. We implemented a computational model to parametrically explore the hypothesis that intercomponent positioning deviating from the manufacturer's recommendations can result in pressure distributions that may predispose to wear of the polyethylene insert. We also investigated the hypothesis that a modern mobile-bearing design may be able to better compensate for imposed misalignments compared with an early two-component design. Methods: Two finite element models of total ankle replacement prostheses were built to quantify peak and average contact pressures on the polyethylene insert surfaces. Models were validated by biomechanical testing of the two implant designs with use of pressure-sensitive film. The validated models were configured to replicate three potential mis- alignments with the most clinical relevance: version of the tibial component, version of the talar component, and relative component rotation of the two-component design. The misalignments were simulated with use of the computer model with physiologically relevant boundary loads. Results: With use of the manufacturer's guidelines for positioning of the two-component design, the predicted average joint contact pressures exceeded the yield stress of polyethylene (18 to 20 MPa). Pressure magnitudes increased as implant alignment was systematically deviated from this reference position. The three-component design showed lower- magnitude contact pressures in the standard position (<10 MPa) and was generally less sensitive to misalignment. Both implant systems were sensitive to version misalignment. Conclusions: In the tested implants, a highly congruent mobile-bearing total ankle replacement design yields more evenly distributed and lower-magnitude joint contact pressures than a less congruent design. Although the mobile- bearing implant reduced susceptibility to aberrant joint contact characteristics that were induced by misalignment, predicted average contact stresses reached the yield stress of polyethylene for imposed version misalignments of >5°.
ACCESSION #
50505473

 

Related Articles

  • Revision Total Ankle Replacement. Myerson, Mark S.; Aiyer, Amiethab A.; Ellington, J. Kent // Essential Surgical Techniques;Apr-Jun2015, Vol. 5 Issue 2, p1 

    The article offers step-by-step instructions for revision total ankle replacement.

  • Obese patients do well with TAR. Stanton, Terry // AAOS Now;Sep2011, Vol. 5 Issue 9, p1 

    The article focuses on the result of a study which examines the survivorship of prosthesis components of obese patients who underwent total ankle replacement (TAR). The study shows that implant survivorship of obese patients who underwent TAR was similar to that of the outcomes in nonobese...

  • Fixed-bearing TAR improves gait function. Stanton, Terry // AAOS Now;Sep2011, Vol. 5 Issue 9, p12 

    The article focuses on a study which assesses the gait mechanics in patients who underwent total ankle replacement (TAR) with fixed-bearing implants. It notes that the study examined two different fixed-bearing TAR implants in 51 patients. The study reveals that patients who received one of the...

  • Short-Term in Vivo Wear of Cross-Linked Polyethylene. Heisel, Christian; Silva, Mauricio; Rosa, Mylene A. Dela; Schmalzried, Thomas P. // Journal of Bone & Joint Surgery, American Volume;Apr2004, Vol. 86-A Issue 4, p748 

    Background: Cross-linked polyethylene was developed to reduce volumetric wear in prosthetic joints. Hip simulator studies have shown promising results with regard to wear reduction. This study evaluated the short-term in vivo wear of a moderately cross-linked polyethylene. Methods: Linear head...

  • Taking a Closer Look at Osteolysis in TAA Patients. MCKEE, JENNIE // AAOS Now;Nov2014, Vol. 8 Issue 11, p13 

    The article discusses the focus of post-arthroplasty osteolysis on total hip and total knee replacements rather than on patients with total ankle arthroplasty (TAA) failure. Physician Murray J. Penner of the University of British Columbia notes the causative factors of polyethylene wear for...

  • Perioperative complications of the MOBILITY total ankle system: comparison with the HINTEGRA total ankle system. KYUNG TAI LEE; YOUNG KOO LEE; KI WON YOUNG; HAK JUN KIM; SHIN YI PARK; JIN SU KIM; KI CHUN KIM // Journal of Orthopaedic Science;May2010, Vol. 15 Issue 3, p317 

    The perioperative complications associated with MOBILITY total ankle replacement arthroplasty have not yet been reported. During the research period from May 2008 to June 2009, a total of 30 consecutive cases of ankle arthritis were treated with surgery. An investigation into the perioperative...

  • Revisionsarthroplastik des oberen Sprunggelenks. Hintermann, B.; Barg, A.; Knupp, M. // Der Orthopäde;Nov2011, Vol. 40 Issue 11, p1000 

    In the last 20 years total ankle replacement has become a viable alternative to arthrodesis for end-stage osteoarthritis of the ankle. Numerous ankle prosthesis designs have appeared on the market in the past and attracted by the encouraging intermediate results reported in the literature, many...

  • Intermediate to Long-Term Outcomes of Total Ankle Replacement with the Scandinavian Total Ankle Replacement (STAR). Daniels, Timothy R.; Mayich, D. Joshua; Penner, Murray J. // Journal of Bone & Joint Surgery, American Volume;6/3/2015, Vol. 97 Issue 11, p895 

    Background: The Scandinavian Total Ankle Replacement (STAR) prosthesis has been in clinical use since 1981, with investigational use in the U.S. since 1998. Few studies of the North American version of the STAR are available. This prospective cohort study analyzed intermediate to long-term...

  • FATIGUE DEVICE FOR TESTING ANKLE JOINT ENDOPROSTHESES. TOADER-PASTI, Cristian; STOIA, Dan Ioan; TOTH-TAŞCĂU, Mirela // Fiability & Durability / Fiabilitate si Durabilitate;2012, Issue 1, p43 

    The paper proposes a model of a fatigue device for testing dedicated to ankle prostheses. The concept of the testing device relies on two aspects: almost any type of ankle prosthesis can be tested on it and it has to work on INSTRON axial-torsion testing machine. Starting from these...