TITLE

Xenon excimer emission from pulsed microhollow cathode discharges

AUTHOR(S)
Moselhy, M.; Shi, W.; Stark, R. H.; Schoenbach, K. H.
PUB. DATE
August 2001
SOURCE
Applied Physics Letters;8/27/2001, Vol. 79 Issue 9, p1240
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
By applying electrical pulses of 20 ns duration to xenon microplasmas, generated by direct current microhollow cathode discharges, we were able to increase the xenon excimer emission by more than an order of magnitude over direct current discharge excimer emission. For pulsed voltages in excess of 500 V, the optical power at 172 nm was found to increase exponentially with voltage. Largest values obtained were 2.75 W of vacuum-ultraviolet optical power emitted from a single microhollow cathode discharge in 400 Torr xenon with a 750 V pulse applied to a discharge. Highest radiative emittance was 15.2 W/cm2. The efficiency for excimer emission was found to increase linearly with pulsed voltages above 500 V reaching values of 20% at 750 V. © 2001 American Institute of Physics.
ACCESSION #
5045928

 

Related Articles

  • Calculation of the parameters of excimer light sources on the basis of a positive column glow discharge. Zvereva, G. N. // Optics & Spectroscopy;Sep2010, Vol. 109 Issue 3, p468 

    We calculate the concentration of plasma and gas-temperature components in a contracted filament of a glow capillary discharge ( R = 0.75 mm) in xenon for pressures of P = 100 and 400 Torr and currents of I = 6-15 mA for cases of with and without cryogenic cooling of the discharge. We find that...

  • Long pulse KrCl excimer laser at 222 nm. Hueber, J.-M.; Fontaine, B.L. // Applied Physics Letters;11/9/1992, Vol. 61 Issue 19, p2269 

    Evaluates the operation of a long-pulse krypton chloride excimer laser at 222 nanometer. Combination of x-ray preionization and double discharge with fast ferrite magnetic switch; Values of the maximum extracted energy and overall energy efficiency; Difference of behavior of some key laser...

  • Effect of Argon Buffer and the UV Preionization Regime on the Electric-Discharge XeCl Laser Parameters. Fedorov, A. I. // Technical Physics Letters;Jul2000, Vol. 26 Issue 7, p625 

    The gas discharge and output radiation parameters were studied in XeCL lasers with various buffer gas compositions (argon vs. neon) and different types of excitation regimes (fast vs. quasi-stationary) in the preionization source. The intervals of specific energy for the neon- and argon-based...

  • Excimer emission from cathode boundary layer discharges. Moselhy, Mohamed; Schoenbach, Karl H. // Journal of Applied Physics;2/15/2004, Vol. 95 Issue 4, p1642 

    The excimer emission from direct current glow discharges between a planar cathode and a ring-shaped anode of 0.75 and 1.5 mm diameter, respectively, separated by a gap of 250 μm, was studied in xenon and argon in a pressure range from 75 to 760 Torr. The thickness of the “cathode...

  • Simulation of gas-discharge UV sources based on a glow discharge in a xenon-chlorine mixture. Golovitskii, A. // Technical Physics;Mar2011, Vol. 56 Issue 3, p371 

    model is developed that makes it possible to calculate the concentration of excimer molecules, halogenides of inert gases, in the positive column of a glow discharge initiated in a chlorine-containing gas mixture. Using this model, one can quantitatively reproduce experimental dependences of the...

  • Subnormal Glow Discharge in a Xe/Cl[sub 2] Mixture in a Narrow Discharge Tube. Shuaibov, A. K.; Dashchenko, A. I.; Shevera, I. V. // Technical Physics;Aug2001, Vol. 46 Issue 8, p1049 

    Electrical and optical characteristics of a subnormal glow discharge in a short (L = 10 cm) discharge tube with an inner diameter of 5 mm are investigated. The dependences of the discharge current-voltage characteristic, the energy deposition in the discharge, the plasma spectral characteristics...

  • Microwave Beam Imaging by Recombination Continuum from the Positive Column of Gas Discharge in a Cesium Vapor�Xenon Mixture. Gitlin, M. S.; Zelenogorsky, V. V.; Perminov, A. O. // Technical Physics Letters;Jun2002, Vol. 28 Issue 6, p445 

    A new sensitive method for imaging of the spatial distribution of microwave intensity is proposed. The method is based on the imaging of the 6P-recombination continuum of cesium, emitted from a nonequilibrium plasma of the positive column of gas discharge in a cesium vapor-xenon mixture. It is...

  • A planar XeCl-exilamp pumped by a low-pressure glow discharge. Sosnin, É. A.; Tarasenko, V. F. // Technical Physics;Dec97, Vol. 42 Issue 12, p1411 

    The energy characteristics of an XeCl exciplex lamp with planar construction pumped by a low-pressure gas discharge are investigated experimentally. When a discharge gap of width 2 cm and a Xe-Cl[sub 2] mixture were used, average radiation powers up to 20 mW were obtained in the wavelength...

  • Electrical test method using high density plasmas for high-end printed circuit boards. Oh, Se-Jin; Kim, Young-Cheol; Chung, Chin-Wook // Review of Scientific Instruments;Jan2012, Vol. 83 Issue 1, p013503 

    A novel electrical test method that uses high-density plasmas, such as inductively coupled discharges, is proposed to detect open/short failures of high-end printed circuit boards (PCBs). The PCB is inserted into the plasma chamber with the top side facing the plasma sheath, and the bottom of...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics