TITLE

Comparison of Eyemetrics and Orbscan automated method to determine horizontal corneal diameter

AUTHOR(S)
Venkataraman, Arvind; Mardi, Sapna K.; Pillai, Sarita
PUB. DATE
March 2010
SOURCE
Indian Journal of Ophthalmology;Mar2010, Vol. 58 Issue 3, p219
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Purpose: To compare horizontal corneal diameter measurements using the Orbscan Eyemetrics function and Orbscan corneal topographer. Materials and Methods: Seventy-three eyes of 37 patients were included in the study. In all cases, the automated white-to-white (WTW) measurements were obtained using Orbscan by two observers. Using the Eyemetrics function, the WTW was measured manually by the same observers from limbus to limbus using the digital caliper passing through the five point corneal reflections on the Orbscan real image. The data was analyzed using SPSS software for correlation, reliability and inter-rater repeatability. Results: The mean horizontal corneal diameter was 11.74 ± 0.32 mm (SD) with the Orbscan and 11.92 ± 0.33 mm (SD) with Eyemetrics Software-based measurement. A good positive correlation (Spearman r = 0.720, P = 0.026) was found between these two measurements. The coefficient of inter-rater repeatability was 0.89 for the Orbscan and 0.94 for the Eyemetrics software measurements on the anterior segment images. The Bland and Altman analysis showed large limits of agreement between Orbscan WTW and Eyemetrics WTW measurements. The intra-session repeatability scores for repeat measurements for the Orbscan WTW and Eyemetrics measurements were good. Conclusion: Eyemetrics can be used to measure WTW and the Eyemetrics measured WTW was longer than the WTW measured by Orbscan.
ACCESSION #
50282357

 

Related Articles

  • Prediction of Forest Stand Attributes Using TerraSAR-X Stereo Imagery. Vastaranta, Mikko; Niemi, Mikko; Karjalainen, Mika; Peuhkurinen, Jussi; Kankare, Ville; Hyypp&#;, Juha; Holopainen, Markus // Remote Sensing;Apr2014, Vol. 6 Issue 4, p3227 

    Consistent, detailed and up-to-date forest resource information is required for allocation of forestry activities and national and international reporting obligations. We evaluated the forest stand attribute prediction accuracy when radargrammetry was used to derive height information from...

  • Correlation between blue-on-yellow perimetry and scanning laser polarimetry with variable corneal compensation measurements in primary open-angle glaucoma. Yu Cheng; Ping Huang // Japanese Journal of Ophthalmology;Nov2009, Vol. 53 Issue 6, p574 

    Abstract Objective  To investigate the correlation between blue-on-yellow perimetry (B/YP) indices and scanning laser polarimetry with variable corneal compensation (GDx VCC) parameters in primary open-angle glaucoma (POAG) patients, and to evaluate whether the two tests can detect similar...

  • Longitudinal relationship between retinal nerve fiber layer thickness parameters assessed by scanning laser polarimetry (GDxVCC) and visual field in glaucoma. Makabe, Kenichi; Takei, Kazuo; Oshika, Tetsuro // Graefe's Archive of Clinical & Experimental Ophthalmology;Apr2012, Vol. 250 Issue 4, p575 

    Purpose: To investigate the longitudinal relationship between retinal nerve fiber layer (RNFL) thickness parameters assessed by scanning laser polarimetry with variable corneal compensation (GDxVCC) and visual field parameters obtained with the Humphrey field analyzer (HFA) in patients with...

  • Monte Carlo simulation of laser beams interaction with the human eye using Geant4. Tendeiro, Diogo; Lopes, Gonçalo; Vieira, Pedro; Santos, José Paulo // BioMedical Engineering OnLine;2014, Vol. 13 Issue 1, p1 

    Background Due to the unique characteristics of the eye, ophthalmologic diagnostic techniques often rely on the photons interaction with the retina to infer its internal structure. Although these techniques are widely used, the interpretation of the generated images is not always fully...

  • Interchangeability of macular thickness measurements between different volumetric protocols of Spectralis optical coherence tomography in normal eyes. Wenner, Yaroslava; Wismann, Stephan; Jäger, Melanie; Pons-Kühnemann, Jörn; Lorenz, Birgit // Graefe's Archive of Clinical & Experimental Ophthalmology;Aug2011, Vol. 249 Issue 8, p1137 

    Backgrounds: To evaluate in healthy eyes the interchangeability of retinal thickness measurements resulting from different protocols of Spectralis optical coherence tomography (OCT, Heidelberg Engineering, Germany). Methods: Three different central volumetric protocols were performed in one...

  • Trans-lamina cribrosa pressure difference correlated with neuroretinal rim area in glaucoma. Ren, Ruojin; Wang, Ningli; Zhang, Xiaojun; Cui, Tongtong; Jonas, Jost // Graefe's Archive of Clinical & Experimental Ophthalmology;Jul2011, Vol. 249 Issue 7, p1057 

    Background: The aim of this work is to prospectively assess the relationship between trans-laminar cribrosa pressure difference and neuroretinal rim area as morphologic surrogate of glaucomatous optic nerve damage. Methods: The study included 22 patients with high-pressure glaucoma, 13 patients...

  • Inbreeding Coefficient in Mass Selection in Maize. Márquez-Sánchez, Fidel; Kang, Manjit S. // Handbook of Formulas & Software for Plant Geneticists & Breeders;2003, p329 

    The article provides information on inbreeding coefficient in mass selection in maize. It presents and defines the equation used in maize inbreeding. It suggests the formula to adjust the variance in the equation.

  • ALTERNATIVE OF COEFFICIENT OF CONCORDANCE. Popov, G. A.; Popova, E. A. // Erasmus Journal for Philosophy & Economics;2013, Vol. 6 Issue 2, p158 

    The shortcomings of classical coefficient of concordance for the case of the expert procedure in the form of a strict ranking are analyzed. The formula that eliminates one of the drawbacks of the classical coefficient of concordance is presented. An alternative version of the coefficient of...

  • USING THE RANGE TO CALCULATE THE COEFFICIENT OF VARIATION. Rhiel, G. Steven // Psychological Reports;Dec2004 Part1, Vol. 95 Issue 3, p1043 

    In this research a coefficient of variation (CVhigh-low) is calculated from the highest and lowest values in a set of data. Use of CVhigh-low when the population is normal, leptokurtic, and skewed is discussed. The statistic is the most effective when sampling from the normal distribution. With...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics