TITLE

Development of a new control device for stabilizing blood level in reservoir during extracorporeal circulation

AUTHOR(S)
Momose, Naoki; Yamakoshi, Rie; Kokubo, Ryo; Yasuda, Toru; Iwamoto, Norio; Umeda, Chinori; Nakajima, Itsuro; Yanagisawa, Mitsunobu; Tomizawa, Yasuko
PUB. DATE
March 2010
SOURCE
Perfusion;Mar2010, Vol. 25 Issue 2, p77
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We developed a simple device that stabilizes the blood level in the reservoir of the extracorporeal circulation open circuit system by measuring the hydrostatic pressure of the reservoir to control the flow rate of the arterial pump. When the flow rate of the venous return decreases, the rotation speed of the arterial pump is automatically slowed down. Consequently, the blood level in the reservoir is stabilized quickly between two arbitrarily set levels and never falls below the pre-set low level. We conducted a basic experiment to verify the operation of the device, using a mock circuit with water. Commercially available pumps and reservoir were used without modification. The results confirmed that the control method effectively regulates the reservoir liquid level and is highly reliable. The device possibly also functions as a safety device.
ACCESSION #
50229747

 

Related Articles

  • FDA safety initiative to address problems with infusion pumps.  // Endocrine Today;Jun2010, Vol. 8 Issue 6, p25 

    The article looks at the new initiative of the U.S. Food and Drug Administration (FDA) which aims to address problems about the safety of using external infusion pumps.

  • FDA & the Reform of the Medical Device Approval Process.  // Biomedical Market Newsletter;5/28/2011, p1 

    The article discusses the actions taken by the U.S. Food and Drug Administration (FDA) to enhance medical device safety in the country. It provides an overview of the regulatory authorities for medical devices. It indicates that FDA strengthens its scientific decision-making to increase the...

  • Aortic arch replacement with moderate hyperthomia and a modified 3-pump circuit. Charumathi, Dasarathan; Vaijyanath, Prashanth; Sekhar, Lavanya // Perfusion;Mar2011, Vol. 26 Issue 2, p141 

    A strategy employing moderate hypothermia for replacement of the aortic arch is proposed to avoid the complications of profound hypothermic circulatory arrest. Two patients underwent complete replacement of the aortic arch using three pumps (Figure 1a — one to perfuse the brain, one for...

  • Promoting Safe Use of Medical Devices. Swayze, Sonia C.; Rich, Suzanne E. // Online Journal of Issues in Nursing;Jan2012, Vol. 17 Issue 1, p1 

    Although patient safety initiatives in the clinical environment have focused primarily on medication errors to date, medical devices also contribute significantly to patient injuries and deaths. This article addresses the Food and Drug Administration's (FDA) efforts to promote safe use of...

  • Providers, suppliers pumped about FDA safety regs. Cantrell, Susan // Healthcare Purchasing News;Aug2012, Vol. 36 Issue 8, p30 

    The article discusses a report titled "Infusion Pump Improvement Initiative, 2010", which was released in 2012 by the U.S. Food and Drug Administration and found that there were 56,000 reports of adverse events linked to infusion pumps in hospitals between 2005 and 2009. A discussion of reaction...

  • CT energy may interact with devices.  // Medical Device Daily;7/15/2008, Vol. 12 Issue 135, p3 

    The article reports on a public safety statement published by the U.S. Food and Drug Administration on July 14, 2008 which stated that some pacemakers, defibrillators, neurostimulators and infusion pumps may present hazard when exposed to X-rays during computed tomography (CT) imaging sessions...

  • In-line filter included into the syringe infusion pump assembly reduces flow irregularities. Brotschi, B.; Grass, B.; Weiss, M.; Doell, C.; Bernet, V. // Intensive Care Medicine;Mar2012, Vol. 38 Issue 3, p518 

    Purpose: To evaluate whether an in-line filter inserted in the syringe pump infusion line assembly influences start-up times and flow irregularities during vertical pump displacement at low infusion rates. Methods: Fluid delivery after syringe pump start-up and after vertical displacement of the...

  • Infusion pump development and implications for nurses. Lee, Paul // British Journal of Nursing;2015 Therapy Supplement, Vol. 24, pS30 

    Infusion pumps are commonplace in today's healthcare settings and their design and development has kept pace with technology over the decades. In the 1970s and 1980s infusion pumps began to emerge in the UK market and were basic, mechanical devices with limited functions. Today, infusion pumps...

  • Subcutaneous infusion in palliative care: the neriaâ„¢ soft infusion set. Gabriel, Janice // British Journal of Nursing;11/22/2012 Supplement, pS14 

    Patients approaching the end of their life may be unable to tolerate the administration of oral medication owing to their underlying disease and/or symptoms, such as nausea and vomiting. Subcutaneous infusion is an alternative route of administration that offers a number of advantages over oral...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics