TITLE

Fast integrator based data acquisition system for the SST-1 Thomson scattering system

AUTHOR(S)
Patel, Kiran; Kumar, Ajai
PUB. DATE
April 2010
SOURCE
Review of Scientific Instruments;Apr2010, Vol. 81 Issue 4, p043501
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
An operational transconductance amplifier based fast charge-integrating module (FCIM) is designed and developed for an easy acquisition of fast Thomson scattered and background signal. FCIM based data acquisition technique can be used for the measurement of charge pulses of <20 ns duration. The response of the module is tested using a standard pulsed charge-generating module. The measuring charge range of the module depends on the integrating capacitor. Comparison of the performance of FCIM to commercially available module shows that it has better dynamic range with higher sensitivity and less measurement error. The module is quite cost effective and has many new features.
ACCESSION #
50173722

 

Related Articles

  • Electron cyclotron emission measurements on JET: Michelson interferometer, new absolute calibration, and determination of electron temperature. Schmuck, S.; Fessey, J.; Gerbaud, T.; Alper, B.; Beurskens, M. N. A.; de la Luna, E.; Sirinelli, A.; Zerbini, M.; JET-EFDA Contributors // Review of Scientific Instruments;Dec2012, Vol. 83 Issue 12, p125101 

    At the fusion experiment JET, a Michelson interferometer is used to measure the spectrum of the electron cyclotron emission in the spectral range 70-500 GHz. The interferometer is absolutely calibrated using the hot/cold technique and, in consequence, the spatial profile of the plasma electron...

  • Experimental observation of relativistic nonlinear Thomson scattering. Chen, Szu-yuan; Maksimchuk, Anatoly; Umstadter, Donald // Nature;12/17/1998, Vol. 396 Issue 6712, p653 

    Reports on the use of an approach to obtain direct experimental confirmation of the theoretical predictions of relativistic Thomson scattering. Details about classical Thomson scattering; Possibility of achieving coherent generation of harmonics, a process that could be potentially utilized for...

  • Microwave losses in metal-ferroelectric-metal thin-film capacitors. Gań≠dukov, M. M.; Gagarin, A. G.; Kozyrev, A. B.; Razumov, S. V.; Tumarkin, A. V.; Altynnikov, A. G. // Technical Physics Letters;Jul2008, Vol. 34 Issue 7, p565 

    The design and technology of microwave ferroelectric capacitors based on Pt/(Ba,Sr)TiO3/Cu thin-film structures are considered. The structural and electrical characteristics of a ferroelectric layer deposited over a Pt film are presented. The frequency dependence of microwave losses in a...

  • Design and Study of the Observation Optics for the Thomson Scattering Planned at Wendelstein 7-X. Cantarini, J.; Knauer, J. P.; Pasch, E. // AIP Conference Proceedings;3/19/2008, Vol. 993 Issue 1, p191 

    The main aim of the Thomson scattering system is the measurement of electron temperature and density profiles with high time and spatial resolution. To cover the whole laser beam line (1.6 m) through the plasma cross section, two ports are provided for the observation optics, which image the...

  • Design study of polychromators for ITER edge Thomson scattering diagnostics. Kajita, Shin; Hatae, Takaki; Kusama, Yoshinori // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E726 

    In this study, we investigate designs for polychromators of the ITER edge Thomson scattering system by means of numerical calculations. For this purpose, we discuss the optimum transmission wavelength ranges of the optical filters and the optimum number of filters. Five different filter...

  • Absolute calibration of LIDAR Thomson scattering systems by rotational Raman scattering. Scannell, R.; Beurskens, M.; Kempenaars, M.; Naylor, G.; Walsh, M.; O'Gorman, T.; Pasqualotto, R. // Review of Scientific Instruments;Apr2010, Vol. 81 Issue 4, p045107 

    Absolute calibration of LIDAR Thomson scattering systems on large fusion devices may be achieved using rotational Raman scattering. The choice of calibrating gas molecule presents different options and design trade-offs and is likely to be strongly dependent on the laser wavelength selected....

  • Chromatographic data acquisition system for determination of natural-gas composition and properties. Buzanovskii, V. // Chemical & Petroleum Engineering;May2009, Vol. 45 Issue 5/6, p364 

    A data acquisition system has been developed for the determination of natural-gas composition and properties, ensuring low cost of the system and a measurement error not exceeding 2 %. The architecture of the system, measurement methods, and investigation results are described.

  • Measure twice and cut once: the carpenter's rule still applies. Kamakura, Wagner // Marketing Letters;Sep2015, Vol. 26 Issue 3, p237 

    In a lead article published by the Journal of Marketing Research in 2007, Bergkvist and Rossiter ( Journal of Marketing Research 44:175-84, ) recommend that 'for the many constructs in marketing that consist of a concrete singular object and a concrete attribute, such as A or A, single-item...

  • METHODOLOGICAL ISSUES AND CHALLENGES IN THE PRODUCTION OF OFFICIAL STATISTICS. PFEFFERMANN, DANNY // Journal of Survey Statistics & Methodology;Dec2015, Vol. 3 Issue 4, p425 