The high speed performance of a scanning probe microscope (SPM) is improved if a microelectromechanical systems (MEMS) device is employed for the out-of-plane scanning motion. We have carried out experiments with MEMS high-speed z-scanners (189 kHz fundamental resonance frequency) in both atomic force microscope and scanning tunneling microscope modes. The experiments show that with the current MEMS z-scanner, lateral tip speeds of 5 mm/s can be achieved with full feedback on surfaces with significant roughness. The improvement in scan speed, obtained with MEMS scanners, increases the possibilities for SPM observations of dynamic processes. Even higher speed MEMS scanners with fundamental resonance frequencies in excess of a megahertz are currently under development.
ACCESSION #
50173721

 

Related Articles

  • Preparation of cantilevered W tips for atomic force microscopy and apertureless near-field scanning optical microscopy. Sun, W. X.; Shen, Z. X.; Cheong, F. C.; Yu, G. Y.; Lim, K. Y.; Lin, J. Y. // Review of Scientific Instruments;Aug2002, Vol. 73 Issue 8, p2942 

    Tip characteristics play an important role in the resolution and sensitivity of scanning probe microscopy. Extensive efforts have been devoted to tip fabrication. Most of the research is focused on scanning tunneling microscopy applications, which require sharp and short tips. Long tips that can...

  • Frequency response of cantilever beams immersed in viscous fluids near a solid surface with applications to the atomic force microscope. Green, Christopher P.; Sader, John E. // Journal of Applied Physics;12/1/2005, Vol. 98 Issue 11, p114913 

    Theoretical models for the frequency response of a cantilever beam immersed in a viscous fluid commonly assume that the fluid is unbounded. Experimental measurements show, however, that proximity to a surface can significantly affect the frequency response of a cantilever beam. In this article,...

  • Compositional mapping of surfaces in atomic force microscopy by excitation of the second normal mode of the microcantilever. Rodríguez, Tomás R.; García, Ricardo // Applied Physics Letters;1/19/2004, Vol. 84 Issue 3, p449 

    We propose a method for mapping the composition of a surface by using an amplitude modulation atomic force microscope operated without tip-surface mechanical contact. The method consists in exciting the first two modes of the microcantilever. The nonlinear dynamics of the tip motion, the...

  • Frequency-modulation atomic force microscopy at high cantilever resonance frequencies using the heterodyne optical beam deflection method. Fukuma, Takeshi; Kimura, Kenjiro; Kobayashi, Kei; Matsushige, Kazumi; Yamada, Hirofumi // Review of Scientific Instruments;Dec2005, Vol. 76 Issue 12, p126110 

    We have developed a frequency-modulation atomic force microscope (FM-AFM) with a wideband cantilever deflection sensor using the heterodyne optical beam deflection method. The method enhances the bandwidth of the deflection measurement up to the maximum frequency for the laser power modulation,...

  • Microscope Flaw More than Microscopic.  // Australasian Science;Jun2003, Vol. 24 Issue 5, p12 

    Reports on the findings of Doctor John Sader of the University of Melbourne's School of Mathematics and Statistics, that a basic feature of Atomic Force Microscope (AFM) design delivers none of its purported benefits and degrades its performance. Information on how AFM operates; History of the...

  • Small amplitude oscillations of a thin beam immersed in a viscous fluid near a solid surface. Green, Christopher P.; Sader, John E. // Physics of Fluids;Jul2005, Vol. 17 Issue 7, p073102 

    The hydrodynamic loading on a solid body moving in a viscous fluid can be strongly affected by its proximity to a surface. In this article, we calculate the hydrodynamic load on an infinitely long rigid beam of zero thickness that is undergoing small amplitude oscillations. The presence of a...

  • AFM Measurement of Step Kinetics for the Growth and Dissolution of Crystallites. Teng, H. Henry // Spectroscopy;Jun2005, Vol. 20 Issue 6, p16 

    Discusses two atomic force microscopy (AFM) techniques that have been used successfully to quantify step movement, direct and indirect measurement of crystallites. Development of AFM introduced in 1986; Methods used in quantifying step movement; Factors that made measuring step speed difficult...

  • How to Gauge Sensor Noise in Closed-Loop AFMs. Cleveland, Jason // R&D Magazine;Jul2005, Vol. 47 Issue 7, p30 

    Focuses on the development of atomic force microscopy (AFM) in nanotechnology. Problems being faced by AFM developers in creating nanometer-scale motion; Factors to consider in noise specification; Features of the Asylum Research MFP-3D AFM.

  • Noncontact scanning impedance imaging in an aqueous solution. Hawkins, Aaron R.; Liu, Hongze; Oliphant, Travis E.; Schultz, Stephen M. // Applied Physics Letters;8/9/2004, Vol. 85 Issue 6, p1080 

    We present a method for imaging based on noncontact electrical impedance measurements and mechanical scanning. Measurement results are shown for an initial system based on this concept. An impedance probe design is presented, applicable to the test system. Line-scan data plots of high impedance...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics