MCNP5 evaluation of a response matrix of a Bonner Sphere Spectrometer with a high efficiency 6LiI (Eu) detector from 0.01 eV to 20 MeV neutrons

Mazrou, Hakim; Idiri, Zahir; Sidahmed, Tassadit; Allab, Malika
May 2010
Journal of Radioanalytical & Nuclear Chemistry;May2010, Vol. 284 Issue 2, p253
Academic Journal
A new approach has been suggested to establish reliable response matrix of a CRNA Bonner Sphere Spectrometer equipped with a high efficiency 10 mm diameter × 2 mm thick 6LiI (Eu) scintillation detector from thermal neutron energy up to 20 MeV. It combines the experimental response functions obtained using a continuous neutron spectrum emitted from an 241Am-Be neutron source of known emission, with those obtained by Monte-Carlo (MC) calculations. Sensitivity analysis has been performed to check the influence of pertinent parameters on the MC computed detector response. The parameters of interest are the density of polyethylene moderators, the cross section library used in MCNP5 and two computing models depending on the interactions of the neutrons in the detector. The calculated responses of the spectrometer to the 241Am-Be neutron source showed discrepancies depending on the sphere diameter when compared to our measured responses. However, this difference was smaller compared with the experiments available in the literature. The enhancement achieved in the present study is partly due to improved modeling in the MC calculations. To correct for the differences observed, a fitting factor has been deduced for each sphere diameter and used to adjust the MC responses to the experimental ones. The obtained results were subsequently compared to the experimental data of GSF-G spheres system obtained for a typical 4 mm diameter × 4 mm thick 6LiI scintillator for four ISO-8529 selected neutron energies (144.0 keV, 565 keV, 2.5 and 14.8 MeV). The present responses were similar in shape but higher, in absolute values, by about two and half times for all spheres owing essentially to the increase in active part of the detector. Finally, the CRNA-BSS response matrix containing 48 energy points from 0.01 eV to 20 MeV for 22 sphere diameters with a mean polyethylene density of 0.944 g/cm3 was constructed by applying a spline interpolation method. The released response matrix was then compared to data available in the literature evaluated by Monte-Carlo calculations for a 4 mm × 4 mm 6LiI crystal scintillator. The obtained response matrix is intended for radiation protection applications at CRNA.


Related Articles

  • Spectrometer for shot-to-shot photon energy characterization in the multi-bunch mode of the free electron laser at Hamburg. Palutke, S.; Gerken, N. C.; Mertens, K.; Klumpp, S.; Mozzanica, A.; Schmitt, B.; Wunderer, C.; Graafsma, H.; Meiwes-Broer, K.-H.; Wurth, W.; Martins, M. // Review of Scientific Instruments;Nov2015, Vol. 86 Issue 11, p1 

    The setup and first results from commissioning of a fast online photon energy spectrometer for the vacuum ultraviolet free electron laser at Hamburg (FLASH) at DESY are presented. With the use of the latest advances in detector development, the presented spectrometer reaches readout frequencies...

  • Methane Detector Used for Emissions Mapping.  // Asian Environmental Technology;Oct/Nov2013, Vol. 17 Issue 4, p6 

    The article offers information on the use of methane detectors for emission and pollution monitoring, control and management services.

  • Role of the magnetic field in electron transportation in a beam-plasma generator. Koroteev, A.; Rizakhanov, R. // Plasma Physics Reports;Dec2010, Vol. 36 Issue 13, p1173 

    The passage of a concentrated beam through the extraction system of a beam plasma generator is investigated on the basis of analysis of variations in the beam diameter and emittance. Evolution of these parameters is analyzed in the final section of the extraction device, which is characterized...

  • A one-dimensional position-sensitive detector for thermal neutrons. Belushkin, A.; Bogdzel';, A.; Zhuravlev, V.; Kutuzov, S.; Levchanovskii, F.; Yong Li; Litvinenko, E.; Nikiforov, A.; Panteleev, Ts.; Prikhod’ko, V.; Chernikov, A.; Churakov, A.; Shvetsov, V. // Instruments & Experimental Techniques;Nov2007, Vol. 50 Issue 6, p737 

    A one-dimensional position-sensitive detector of thermal neutrons has been developed to equip high-efficiency neutron spectrometers at the ИБР-2 research reactor. The detector is based on a multiwire proportional chamber filled with a mixture of 3He + CF4 and has an active area of 200...

  • Simultaneous translational temperature measurements of different atomic species in plasma flows using scanning Fabry-Perot interferometry. Löhle, Stefan; Lein, Sebastian // Review of Scientific Instruments;May2012, Vol. 83 Issue 5, p053111 

    A revised scientific instrument to measure simultaneously kinetic temperatures of different atoms from their optical emission profile is reported. Emission lines are simultaneously detected using one single scanning Fabry-Perot-interferometer (FPI) for a combined spectroscopic setup to acquire...

  • High-resolution Fabry—Pérot interferometric emission measurements of the 535.046 nm thallium line in a see-through hollow cathode discharge. Taylor, N.; Omenetto, N.; Smith, B. W.; Winefordner, J. D. // Applied Physics B: Lasers & Optics;Sep2007, Vol. 89 Issue 1, p107 

    A thallium see-through hollow cathode lamp, or galvatron, is investigated for applications as a narrow band atomic line filter. In order to determine the resolving power of this atom reservoir, high resolution emission profile measurements of the 535.046 nm line were obtained by a scanning...

  • Nitrogen dioxide, sulfur dioxide, and ammonia detector for remote sensing of vehicle emissions. Burgard, Daniel A.; Dalton, Thomas R.; Bishop, Gary A.; Starkey, John R.; Stedman, Donald H. // Review of Scientific Instruments;Jan2006, Vol. 77 Issue 1, p014101 

    A remote sensor for measuring on-road vehicles passing the sensor in real time is described. This sensor expands upon previous technology that measured carbon monoxide, carbon dioxide, and exhaust hydrocarbons in the IR and nitric oxide in the UV. The design adds the capability to measure...

  • Trends in Leak Tightness Testing. Sagi, Hemi // Quality;Oct2004, Vol. 43 Issue 10, p20 

    Focuses on the impact of the emission requirements on the quality of various products in the U.S. Use of leak detectors in finding pinholes; Definition of leak testing parameters; Measurement of flow rates. INSET: Fill Time: Stability and Test Time.

  • Nano-gold measures industrial emissions.  // TCE: The Chemical Engineer;Jul/Aug2009, Issue 817/818, p15 

    The article reports that researchers at the Royal Melbourne Institute Technology (RMIT) University in Australia have found that using nano-engineered gold to measure mercury in industrial emissions is more accurate than existing sensors. It is stated that the study used electrochemical processes...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library