TITLE

Glenohumeral Contact Kinematics in Patients After Total Shoulder Arthroplasty

AUTHOR(S)
Massimini, Daniel F.; Guoan Li; Warner, Jon P.
PUB. DATE
April 2010
SOURCE
Journal of Bone & Joint Surgery, American Volume;Apr2010, Vol. 92-A Issue 4, p915
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Knowledge of in vivo glenohumeral joint contact mechanics after total shoulder arthroplasty may provide insight for the improvement of patient function, implant longevity, and surgical technique. The objective of this study was to determine the in vivo glenohumeral joint contact locations in patients after total shoulder arthroplasty. We hypothesized that the glenohumeral joint articular contact would be centered on the glenoid surface because of the ball-in-socket geometric features of the implants. Methods: Dual-plane fluoroscopic images and computer-aided design models were used to quantify patient-specific glenohumeral articular contact in thirteen shoulders following total shoulder arthroplasty. The reconstructed shoulder was imaged at arm positions of 0°, 45°, and 90° of abduction (in the coronal plane) and neutral rotation and at 900 of abduction with maximum internal and external rotation. The patients were individually investigated, and their glenohumeral joint contact centroids were reported with use of contact frequency. Results: In all positions, the glenohumeral joint contact centroids were not found at the center of the glenoid surface but at an average distance (and standard deviation) of 11.0 ± 4.3 mm from the glenoid center. Forty (62%) of the sixty-five total contact occurrences were found on the superior-posterior quadrant of the glenoid surface. The position of 0° of abduction in neutral rotation exhibited the greatest variation of quadrant contact location; however, no contact was found on the superior-anterior quadrant of the glenoid surface in this position. Conclusions: In vivo, glenohumeral joint contact after total shoulder arthroplasty is not centered on the glenoid surface, suggesting that kinematics after shoulder arthroplasty may not be governed by ball-in-socket mechanics as traditionally thought. Although contact locations as a function of arm position vary among patients, the superior-posterior quadrant seems to experience the most articular contact in the shoulder positions tested.
ACCESSION #
49476018

 

Related Articles

  • TREATMENT OF GLENOHUMERAL ARTHRITIS WITH A HEMIARTHROPLASTY: A MINIMUM FIVE-YEAR FOLOW-UP OUTCOME STUDY. Wirth, Michael A.; Tapscott, R. Stacy; Southworth, Carleton; Rochwood Jr., Charles A. // Journal of Bone & Joint Surgery, American Volume;May2006, Vol. 88-A Issue 5, p964 

    Background: Glenohumeral hemiarthroplasty is well established as a method to treat glenohumeral arthritis. This study was designed to report longer-term results and to provide a decision model to assist surgeons in achieving successful outcomes. Our selection strategy for hemiarthroplasty...

  • Glenoid Replacement in Total Shoulder Arthroplasty. Keller, Julie; Bak, Sean; Bigliani, Louis U.; Levine, William N. // Orthopedics;Mar2006, Vol. 29 Issue 3, p221 

    Discusses the contribution of advances in glenoid replacement to improved patient outcomes and satisfaction following total shoulder arthroplasty. Therapeutic application of glenohumeral arthroplasty which was introduced by Charles Neer II in the early 1950s; Indications and contraindications of...

  • Determination of a reference system for the three-dimensional study of the glenohumeral relationship. Verstraeten, Tom; Deschepper, Ellen; Jacxsens, Matthijs; Walravens, Stig; Coninck, Brecht; Pouliart, Nicole; Wilde, Lieven // Skeletal Radiology;Aug2013, Vol. 42 Issue 8, p1061 

    Objective: Knowledge of the normal and pathological three-dimensional glenohumeral relationship is imperative when planning and performing a total shoulder arthroplasty. There is, however, no consensus on which references should be used when studying this relationship. The purpose of the present...

  • Glenoid Loosening in Response to Dynamic Multi-Axis Eccentric Loading. Roche, C.; Angibaud, L.; Flurin, P. H.; Wright, T.; Zuckerman, Joseph // Bulletin of the NYU Hospital for Joint Diseases;2006, Vol. 63 Issue 3/4, p88 

    Glenoid loosening is a common failure mode observed in total shoulder arthroplasty. In an effort to isolate the affect of differing fixation techniques on loosening, an edge displacement test was conducted using two, pear-shaped, UHMWPE glenoid designs: one keel and one peg, each having a...

  • Long-Term Follow-up of Shoulder Hemiarthroplasty for Glenohumeral Osteoarthritis. Levine, William N.; Fischer, Charla R.; Duong Nguyen; Flatow, Evan L.; Ahmad, Christopher S.; Bigliani, Louis U. // Journal of Bone & Joint Surgery, American Volume;11/21/2012, Vol. 94-A Issue 22, p2053 

    The article presents a study on the long term clinical outcomes on the use of hemiarthroplasty for glenohumeral osteoarthritis at the Center for Shoulder, Elbow and Sports Medicine in Columbia University Medical Center in New York. It involves 30 patients with glenohumeral osteoarthritis who...

  • Biomechanical evaluation of knotless anterior and posterior Bankart repairs. Martetschläger, Frank; Michalski, Max; Jansson, Kyle; Wijdicks, Coen; Millett, Peter // Knee Surgery, Sports Traumatology, Arthroscopy;Sep2014, Vol. 22 Issue 9, p2228 

    Purpose: The value of modern tape-like suture materials and the influence of the number of anchors inserted for arthroscopic Bankart repairs compared to the intact state have yet to be investigated. It was hypothesised: (1) suture-tape repairs will show higher biomechanical strength than common...

  • Duocentric reversed shoulder prosthesis and Personal Fit templates: innovative strategies to optimize prosthesis positioning and prevent scapular notching. Trouilloud, P.; Gonzalvez, M.; Martz, P.; Charles, H.; Handelberg, F.; Nyffeler, R.; Baulot, E. // European Journal of Orthopaedic Surgery & Traumatology;May2014, Vol. 24 Issue 4, p483 

    We describe our experience with a new system of patient-specific template called Personal Fit, which is unique in shoulder surgery and used in combination with Duocentric prosthesis. The reverse prosthesis's concept is the invention of Paul Grammont, developed with Grammont's team of Dijon...

  • In vivo kneeling biomechanics after posterior stabilized total knee arthroplasty. George R. Hanson; Sang E. Park; Angela L. Moynihan; Andrew A. Freiberg; Guoan Li // Journal of Orthopaedic Science;Sep2007, Vol. 12 Issue 5, p476 

    Abstract Background  Kneeling is one of the activities sought by patients after total knee arthroplasty (TKA). This study investigated the six degrees of freedom (DOF) kinematics and three-dimensional (3D) contact during weight-bearing kneeling. Methods  A total of 16 South Korean...

  • Use total shoulder arthroplasty. Levine, William N. // Orthopedics Today;May2008, Vol. 28 Issue 5, p96 

    The author argues in favor of the use of total shoulder arthroplasty in the case of a young patient with shoulder osteoarthritis (OA). The author states that he would rather do one good operation that will last longer than do an inferior operation that the physician has to revise after several...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics