The present article describes the results and findings explored in the course of the development of the analytically capable prototype of continuous time-of-flight (CTOF) mass spectrometer. Currently marketed pulsed TOF (PTOF) instruments use ion introduction with a 10 ns or so pulse width, followed by a waiting period roughly 100 μs. Accordingly, the sample is under excitation in 10-4 part of the total measuring time. This very low duty cycle severely limits the sensitivity of the PTOF method. A possible approach to deal with this problem is to use linear sinusoidal dual modulation technique (CTOF) as described in this article. This way the sensitivity of the method is increased, due to the 50% duty cycle of the excitation. All other types of TOF spectrometer use secondary electron multiplier (SEM) for detection, which unfortunately discriminates in amplification in favor of the lighter ions. This discrimination effect is especially undesirable in a mass spectrometric method, which targets high mass range. In CTOF method, SEM is replaced with Faraday cup detector, thus eliminating the mass discrimination effect. Omitting SEM is made possible by the high ion intensity and the very slow ion detection with some hundred hertz detection bandwidth. The electrometer electronics of the Faraday cup detector operates with amplification 1010 V/A. The primary ion beam is highly monoenergetic due to the construction of the ion gun, which made possible to omit any electrostatic mirror configuration for bunching the ions. The measurement is controlled by a personal computer and the intelligent signal generator Type Tabor WW 2571, which uses the direct digital synthesis technique for making arbitrary wave forms. The data are collected by a Labjack interface board, and the fast Fourier transformation is performed by the software. Noble gas mixture has been used to test the analytical capabilities of the prototype setup. Measurement presented proves the results of the mathematical calculations as well as the future potentiality for use in chemical analysis of gaseous mixtures.
ACCESSION #
48911804

 

Related Articles

  • Reflectron velocity map ion imaging. Leskiw, Brian D.; Myung Hwa Kim; Hall, Gregory E.; Suits, Arthur G. // Review of Scientific Instruments;Oct2005, Vol. 76 Issue 10, p103102 

    We report the first demonstration of velocity map ion imaging in a reflectron configuration. Under these conditions, the velocity-resolving capabilities associated with velocity map ion imaging are achieved simultaneously with long flight times and the high mass resolution characteristic of...

  • Method for an accurate calibration of the flight-time-focused time-of-flight atom probe. Ren, Duomin; Tsong, T. T.; McLane, S. B. // Review of Scientific Instruments;Oct86, Vol. 57 Issue 10, p2543 

    A method is devised to determine accurately the flight-path constant, the time-delay constant, and the pulse factor for the flight-time-focused time-of-flight atom probe field ion microscope. Using these constants, masses of ions can be determined routinely to the accuracy of ∼0.005 to 0.06...

  • Design and performance of an electrospray ionization time-of-flight mass spectrometer. Håkansson, Kristina; Zubarev, Roman A.; Håkansson, Per; Laiko, Viktor; Dodonov, Alexander F. // Review of Scientific Instruments;Jan2000, Vol. 71 Issue 1 

    In order to circumvent the limitations of a quadrupole mass filter, which so far has been the most common mass analyzer for use with electrospray ionization, a mass spectrometer coupling electrospray with time-of-flight mass analysis has been constructed. The design of this spectrometer,...

  • Searching for Rare Decay Modes in the Reaction 238U+4He (40 MeV). Pyatkov, Yu.; Trzaska, W.; Mutterer, M.; Yamaletdinov, S.; Tjukavkin, A.; Bolgov, D.; Kamanin, D.; Khlebnikov, S.; Kopach, Yu.; Kuznetsova, E.; Lavrova, J.; Lyapin, V.; Sillanpää, M.; Tishchenko, V.; Tyurin, G. // AIP Conference Proceedings;2007, Vol. 912 Issue 1, p144 

    In the present paper we describe an experiment performed on the reaction 238U + 4He (40 MeV) using a two-arm TOF-E (time-of-flight vs. energy) spectrometer with micro- channel plate detectors and mosaics of PIN diodes. This experiment has aimed at searching for fine structures in the total...

  • Ways to improve the analytical characteristics of magnetic-sector time-of-flight mass analyzers. Nuriev, K. Z.; Nurubeyli, T. K.; Nurubeyli, Z. K. // Technical Physics Letters;Dec2009, Vol. 35 Issue 12, p1156 

    Ways to improve the characteristics of analyzers and the parameters of ion beams in magnetic-sector time-of-flight mass spectrometers with axisymmetric electrostatic fields are considered. It is shown that the analyzer transmission can be improved by eliminating the edge effects at the analyzer...

  • Design and performance of an atmospheric pressure sampling interface for ion-trap/time-of-flight mass spectrometry. Setz, Patrick D.; Schmitz, Thomas A.; Zenobi, Renato // Review of Scientific Instruments;Feb2006, Vol. 77 Issue 2, p024101 

    An ion-trap/time-of-flight mass spectrometer in combination with an atmospheric pressure sampling interface was developed in order to simultaneously profit from the ease of sample handling at ambient pressure, from the storage and accumulation capabilities of an ion trap, and from the...

  • New time-of-flight mass spectrometer for improved mass resolution, versatility, and mass spectrometry/mass spectrometry studies. Pinkston, J. David; Rabb, Martin; Watson, J. Throck; Allison, John // Review of Scientific Instruments;Apr1986, Vol. 57 Issue 4, p583 

    Reported here is the design and experimental investigation of the performance characteristics of a new time-of-flight (TOF) mass spectrometer. The instrument combines the advantages of beam deflection for ion pulse formation with an electrostatic analyzer which reduces the energy spread of the...

  • MASTIF: Mass analysis of secondaries by time-of-flight technique. A new approach to secondary ion mass spectrometry. Gruntman, M. A. // Review of Scientific Instruments;Oct89, Vol. 60 Issue 10, p3188 

    A new approach to surface studies by time-of-flight secondary ion mass spectrometry is proposed. The time-of-flight technique is implemented in an unconventional way utilizing a continuousprobing beam. The "birth" moment of the secondary ion is fixed by the detection of secondary electrons...

  • A time-of-flight spectrometer for low-energy neutral and ionized alkalis. Kimmel, G. A.; Cooper, B. H. // Review of Scientific Instruments;Mar93, Vol. 64 Issue 3, p672 

    A time-of-flight spectrometer has been developed for measuring velocity- and angle-resolved distributions of neutral and ionized alkali atoms in the range of several electron volts to several thousand electron volts. The spectrometer is mounted on a rotating platform inside a previously existing...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics