TITLE

Polymer screening by radiofrequency glow discharge time-of-flight mass spectrometry

AUTHOR(S)
Lobo, L.; Tuccitto, N.; Bordel, N.; Pereiro, R.; Pisonero, J.; Licciardello, A.; Tempez, A.; Chapon, P.; Sanz-Medel, A.
PUB. DATE
April 2010
SOURCE
Analytical & Bioanalytical Chemistry;Apr2010, Vol. 396 Issue 8, p2863
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The aim of this work is to optimise and evaluate radiofrequency glow discharge (RF GD) time-of-flight mass spectrometry (TOFMS) for identification of organic polymers. For this purpose, different polymers including poly[methylmethacrylate], poly[styrene], polyethylene terephthalate-co-isophthalate and poly[alpha-methylstyrene] have been deposited on silicon wafers and the RF GD-TOFMS capabilities for qualitative identification of these polymeric layers by molecular depth profiling have been investigated. Although some molecular information using the RF continuous mode is available, the pulsed mode offers a greater analytical potential to characterise such organic coatings. Some formed polyatomic ions have proved to be useful to identify the different polymer layers, confirming that layers having similar elemental composition but different polymer structure could be also differentiated and identified. [Figure not available: see fulltext.]
ACCESSION #
48746703

 

Related Articles

  • Critical evaluation of the potential of radiofrequency pulsed glow discharge-time-of-flight mass spectrometry for depth-profile analysis of innovative materials. Pisonero, Jorge; Bordel, Nerea; Gonzalez de Vega, Claudia; Fernández, Beatriz; Pereiro, Rosario; Sanz-Medel, Alfredo // Analytical & Bioanalytical Chemistry;Jul2013, Vol. 405 Issue 17, p5655 

    The combination of radiofrequency pulsed glow discharge (RF-PGD) analytical plasmas with time-of-flight mass spectrometry (TOFMS) has promoted the applicability of this ion source to direct analysis of innovative materials. In this sense, this emerging technique enables multi-elemental depth...

  • Direct chemical in-depth profile analysis and thickness quantification of nanometer multilayers using pulsed-rf-GD-TOFMS. Valledor, R.; Pisonero, J.; Bordel, N.; Martín, J. I.; Quirós, C.; Tempez, A.; Sanz-Medel, A. // Analytical & Bioanalytical Chemistry;Apr2010, Vol. 396 Issue 8, p2881 

    Nanometer depth resolution is investigated using an innovative pulsed-radiofrequency glow discharge time-of-flight mass spectrometer (pulsed-rf-GD-TOFMS). A series of ultra-thin (in nanometers approximately) Al/Nb bilayers, deposited on Si wafers by dc-magnetron sputtering, is analyzed. An Al...

  • Charge carrier transport in conjugated polymers. Hertel, D.; Bassler, H. // Journal of Chemical Physics;5/8/1999, Vol. 110 Issue 18, p9214 

    Studies the charge carrier mobility in ladder-type polymers by using the time-of-flight (TOF) mass spectrometry method. Characteristics of the TOF signals featuring nondispersive charge transport in terms of the disorder formalism; Hole mobilities obtained from the transprot.

  • Measurement of velocity distribution functions of neutral particles in ion source plasma. Kitatani, K.; Kasuya, T.; Nakayama, T.; Yamamoto, K.; Wada, M. // Review of Scientific Instruments;Feb2002, Vol. 73 Issue 2, p958 

    The velocity distribution function of the gas effusing from a 5.5-cm-diam, 5-cm-long small ion source was measured by the mass separated time-of-flight method. The measured distribution function could be fitted to a Maxwellian distribution before the commencement of a discharge, when the...

  • Charge carrier mobility in poly(p-phenylenevinylene) studied by the time-of-flight technique. Lebedev, E.; Dittrich, Th. // Applied Physics Letters;11/3/1997, Vol. 71 Issue 18, p2686 

    Investigates the charge carrier transport in poly(p-phenylenevinylene) (PPV) using the time-of-flight technique. Determination of mobilities in PPV positive carriers; Analysis of the dispersion parameters in the context of a multiple trapping model; Range of the drift mobility of the positive...

  • Measurements of charge mobility and diffusion coefficient of conjugated electroluminescent polymers by time-of-flight method. Hao-En Tseng; Tzu-Hao Jen, Jan; Kang-Yung Peng; Show-An Chen // Applied Physics Letters;3/1/2004, Vol. 84 Issue 9, p1456 

    Charge mobilities (μ) and diffusion coefficients (D) of hole (μ[sub h], D[sub h]) and electron (μ[sub e], D[sub e]) of the conjugated electroluminescent polymers, poly(phenylene vinylene)s and polyfluorenes, have been measured by fitting of a theoretical photocurrent transient equation...

  • Neutron-scattering study of the vibrational behavior of trehalose aqueous solutions. Branca, C.; Magazu, S.; Migliardo, F.; Romeo, G.; Villari, V.; Wanderlingh, U.; Colognesi, D. // Applied Physics A: Materials Science & Processing;Dec2002 Supplement, Vol. 74 Issue 6, ps452 

    Neutron spectra for hydrated trehalose samples have been obtained by using the time-of-flight spectrometer TOSCA at the ISIS Pulse Neutron Facility (Rutherford Appleton Laboratory, Chilton, UK). Neutron spectra have been compared to the absorbance spectra obtained by Fouriertransform infrared...

  • Pulsed rf-GD-TOFMS for depth profile analysis of ultrathin layers using the analyte prepeak region. Pisonero, J.; Valledor, R.; Licciardello, A.; Quirós, C.; Martín, J.; Sanz-Medel, A.; Bordel, N. // Analytical & Bioanalytical Chemistry;Oct2012, Vol. 403 Issue 8, p2437 

    Direct solid analysis of ultrathin layers is investigated using pulsed radiofrequency (rf) glow discharge (GD) time-of-flight mass spectrometry (TOFMS). In particular, previous studies have always integrated the detected ion signals in the afterglow region of the rf-GD pulse, which is known to...

  • Spectroscopic evaluation of a compact magnetically boosted radiofrequency glow discharge for time-of-flight mass spectrometry. Vega, P.; Pisonero, J.; Bordel, N.; Tempez, A.; Ganciu, M.; Sanz-Medel, A. // Analytical & Bioanalytical Chemistry;May2009, Vol. 394 Issue 1, p373 

    A compact magnetically boosted radiofrequency glow discharge (GD) has been designed, constructed and its analytical potential evaluated by its coupling to a mass spectrometer (MS). Simple modifications to the original source configuration permitted the insertion of permanent magnets. Small...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics