Primary Cementless Total Hip Arthroplasty with an Alumina Ceramic-on-Ceramic Bearing

Petsatodis, George E.; Papadopoulos, Pericles P.; Papavasiiou, Kyriakos A.; Hatzokos, Ippokratis G.; Agathangelidis, Fion G.; Christodoulou, Anastasios G.
March 2010
Journal of Bone & Joint Surgery, American Volume;Mar2010, Vol. 92-A Issue 3, p639
Academic Journal
Background: The biological problems related to wear debris after total hip arthroplasty have stimulated renewed interest in alternatives to metal-on-polyethylene bearing surfaces. Methods: We retrospectively evaluated the clinical and radiographic results of 100 patients who had undergone a total of 109 primary total hip arthroplasties with a cementless alumina ceramic-on-ceramic prosthesis between January 1985 and December 1989. The mean age of the patients at the time of the index arthroplasty was forty-six years. Clinical evaluation was performed with use of the Charnley modification of the Merle d'Aubigné-Postel scale. Seventy-eight patients who had had a total of eighty-five arthroplasties were available for follow-up evaluation at an average of 20.8 years. The patients' average age at the time of the latest follow-up was 66.8 years. Results: Six hips (six acetabular cups and one femoral stem) in six patients underwent revision. Aseptic loosening of the cup combined with focal osteolysis was the cause of all six revisions. In one patient, the stem was also revised because of aseptic loosening. Atthetime of final follow-up, the resultwas excellent(accordingtothe Merle d'Aubigné-Postel scale) in 68% of the hips, good in 19%, fair in 9%, and poor in 4%. The mean Merle d'Aubigné-Postel score improved from 7.9 points preoperatively to 16.9 points postoperatively (p < 0.001). The cumulative rate of survival of the prostheses was 84.4% at 20.8 years. Conclusions: The results of these cementless ceramic-on-ceramic total hip arthroplasties continued to be satisfactory at a minimum of twenty years postoperatively. The improved design of contemporary prostheses and the new generation of ceramic-on-ceramic bearing surfaces may lead to even better long-term results.


Related Articles

  • Femoral stem wear in cemented total hip replacement. Zhang, H. -Y.; Blunt, L.; Jiang, X. -Q.; Brown, L.; Barrans, S.; Zhao, Y. // Proceedings of the Institution of Mechanical Engineers -- Part H;Jul2008, Vol. 222 Issue 5, p583 

    The great success of cemented total hip replacement to treat patients with end-stage osteoarthritis and osteonecrosis has been well documented. However, its long-term survivorship has been compromised by progressive development of aseptic loosening, and few hip prostheses could survive beyond 25...

  • Long-term (20- to 25-year) Results of an Uncemented Tapered Titanium Femoral Component and Factors Affecting Survivorship. Streit, Marcus; Innmann, Moritz; Merle, Christian; Bruckner, Thomas; Aldinger, Peter; Gotterbarm, Tobias // Clinical Orthopaedics & Related Research;Oct2013, Vol. 471 Issue 10, p3262 

    Background: Uncemented femoral components in primary total hip arthroplasty (THA) are commonly used today, but few studies have evaluated their survival into the third decade. Questions/purposes: We evaluated (1) survivorship using femoral revision for any reason as the end point; (2)...

  • Optimizing the Femoral Component Cement Mantle in Total Hip Arthroplasty. Dennis, Douglas A.; Lynch, Christopher B. // Orthopedics;Aug2005 Supplement, Vol. 28, ps867 

    Aseptic loosening is a common cause of long-term failure of cemented femoral components in hip arthroplasty. Initiation of aseptic loosening has been associated with suboptimal cement mantle thickness and uniformity with the resultant progressive development of detrimental cement mantle defects....

  • Biomechanical comparison of three cemented stem removal techniques in revision hip surgery. Tóth, Kálmán; Sisák, Krisztián; Wellinger, Károly; Manó, Sándor; Horváth, Gyöngyi; Szendrői, Miklós; Csernátony, Zoltán // Archives of Orthopaedic & Trauma Surgery;Jul2011, Vol. 131 Issue 7, p1007 

    Background: There are various techniques available to remove a cemented femoral component and distal cement in the case of septic or aseptic loosening, periprosthetic or component fracture. The present study describes the mechanical effects of three techniques: the transfemoral approach (TFA),...

  • Nonunion of the femoral neck: Possibilities and limitations of the various treatment modalities. Raaymakers, Ernst L. F. B.; Marti, René K. // Indian Journal of Orthopaedics;Jan-Mar2008, Vol. 42 Issue 1, p13 

    Nowadays in cases of nonunions of the femoral neck, the surgeon is tempted to perform prosthetic replacement of the hip, more so if there is also evidence of avascular necrosis of the head of femur. This provides rapid pain relief and allows early mobilization. However, long-term results of hip...

  • Total Hip Arthroplasty with an Uncemented Tapered Femoral Component. McLaughlin, Jeffrey R.; Lee, Kyla R. // Journal of Bone & Joint Surgery, American Volume;Jun2008, Vol. 90-A Issue 6, p1290 

    Background: Excellent intermediate-term results with use of tapered femoral components in primary total hip arthroplasty have been reported. The purpose of this study was to update our previous report and to evaluate the outcome of total hip arthroplasty with use of the porous Taperloc femoral...

  • Good Diagnostic Performance of Early Migration as a Predictor of Late Aseptic Loosening of Acetabular Cups. Nieuwenhuijse, Marc J.; Valstar, Edward R.; Kaptein, Bart L.; Nelissen, Rob G.H.H. // Journal of Bone & Joint Surgery, American Volume;5/16/2012, Vol. 94-A Issue 10, p874 

    Background: Excessive early migration of femoral stems following total hip arthroplasty and tibial components following total knee arthroplasty is associated with their long-term survival and allows reliable early evaluation of implant perfor-mance. However, a similar relationship involving...

  • Symptomatic Aseptic Hydrogen Pneumarthrosis as a Sign of Crevice Corrosion Following Total Hip Arthroplasty with a Modular Neck. Weber, Alexander E.; Skendzel, Jack G.; Waxman, David L.; Blaha, John D. // Case Connector;2013, Vol. 3 Issue 3, p1 

    The article presents a case series involving six patients with symptomatic aseptic hydrogen pneumarthrosis after total hip arthroplasty. All patients have experienced acute onset of pain in the hip and groin. The complication of symptomatic hydrogen pneumarthrosis was postulated as an early...

  • Revision Hip Arthroplasty: Infection is the Most Common Cause of Failure. Jafari, S.; Coyle, Catelyn; Mortazavi, S.; Sharkey, Peter; Parvizi, Javad // Clinical Orthopaedics & Related Research;Aug2010, Vol. 468 Issue 8, p2046 

    Revision total hip arthroplasty (THA), although relieving pain and restoring function, fails in some patients. In contrast to failures in primary THA, the frequency of the causes of failure in revision THA has been less well established. We therefore determined the rate of each failure mode and...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics