TITLE

Emission characteristics of H- ion source with inverse gas magnetron geometry

AUTHOR(S)
Baturin, V. A.; Litvinov, P. A.; Pustovoitov, S. A.; Karpenko, A. Yu.
PUB. DATE
February 2010
SOURCE
Review of Scientific Instruments;Feb2010, Vol. 81 Issue 2, p02A710
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The work is dedicated to the experimental investigation of the intense volume-plasma H- ion source. Preliminary experimental researches of two parameters of the upgraded source—emission density of H- ions and gas flow—are represented below. In plasma volume of noncesium H- ion source, the conditions for obtaining of increased density of H- ions in the field of adjoining to the emission aperture were realized. The advancing of electrode system of the emission chamber of a source has allowed receiving the value of an emission density of H- ions equal to 600 mA/cm2.
ACCESSION #
48352598

 

Related Articles

  • Some characteristics of a cylindrical mesh hollow-cathode magnetron ion source (abstract). Miljevic, V. I. // Review of Scientific Instruments;Apr94, Vol. 65 Issue 4, p1398 

    A hollow-cathode magnetron ion source, based on a new type of hollow-cathode discharge [V. Miljević, Phys. Lett. A 92, 439 (1982); V. Miljević, VI ESCAMPIG, Oxford (1982), p. 123; V. Miljević, VII ESCAMPIG, Lisbon (1984), p. 166], is presented. This ion source has all the good...

  • Hollow cathode magnetron ion source with axial extraction. II. Miljevic, Vujo I. // Review of Scientific Instruments;Feb1998, Vol. 69 Issue 2, p1054 

    Evaluates the hollow cathode magnetron ion source with axial extraction. Dependence of the plasma column on discharge and ion current conditions; Assurance of the needed ion concentration for the ion current; Relationship between the plasma column and extracted ion current.

  • Operational characteristics of the impregnated-electrode-type liquid-metal ion source with multiple tip and reservoirs. Gotoh, Y.; Yoshida, K.; Kawai, T.; Fukayama, N.; Ogata, Y.; Tsuji, H.; Ishikawa, J. // Review of Scientific Instruments;Apr94, Vol. 65 Issue 4, p1351 

    A new type of impregnated-electrode-type liquid-metal ion source, which eliminated the heating problem in the previous source, has been developed with multiple tip and reservoirs (TAR's). In the present ion source, the TAR's are connected electrically in series by modifying the TAR holding...

  • Studies on a Magnetron Source. Moehs, D. P. // AIP Conference Proceedings;2002, Vol. 639 Issue 1, p115 

    In working toward a less noisy H[sup -] magnetron source, a new diagnostic tool consisting of a scannable Faraday Cup Array has been developed and installed on the Fermilab H[sup -] ion source test bench. The array consists of 14 identical Faraday cups with 1 mm diameter entrance holes spaced...

  • Performance of the Magnetron H- Source on the BNL 200 MeV Linac. Alessi, James G. // AIP Conference Proceedings;2002, Vol. 642 Issue 1, p279 

    A magnetron surface plasma H-ion source has been used at Brookhaven since 1982 for injection into the 200 MeV linac. Since 1989, this source has operated with a circular aperture, injecting into an RFQ. The source typically produces 90-100 mA of H[sup -] at 35 keV, in 700 µs pulses at up to...

  • Comparative analysis of continuous-wave surface-plasma negative ion sources with various discharge geometry. Belchenko, Yu; Sanin, A.; Sotnikov, O. // Review of Scientific Instruments;2014, Vol. 85 Issue 2, p1 

    Negative ion extraction from continuous-wave (CW) magnetron and semiplanotron discharges was studied and it was compared with that for the source with Penning electrode geometry. The CW negative ion beam up current to 13 mA was extracted from the magnetron source with emission aperture of 3.5 mm...

  • The status of Deutsches Elektronen-Synchroton H[sup -] sources. Peters, J. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1045 

    Reports on the status of two different types of H[sup -] ion sources at Deutsches Elektronen Synchrotron magnetron. Operating history of the magnetron source; Construction history and extraction system of the radio frequency-driven volume source; Operation of the spectrometer einzel lens...

  • A small unbalanced magnetron sputtering source with multipole magnetic field anode. Zheng, Sixiao; Sun, Guanqing; Wang, Peilu; Liao, Xiaodong // Review of Scientific Instruments;Apr94, Vol. 65 Issue 4, p1331 

    A study of a small unbalanced magnetron source with a multipole cusp magnetic field anode is described. The coaxial magnetron principle was extended to the small unbalanced planar magnetron source. In the radial arrangement of magnets, the S pole of the magnet is directed toward the center of...

  • The status of DESY H[sup -] sources. Peters, J. // Review of Scientific Instruments;Feb1998, Vol. 69 Issue 2, p992 

    Describes the operation of negative hydrogen sources in Hamburg, Germany. Reduction of the duty cycle of the magnetron using a heater for cathode temperature control; Effect of coating sputtering on the lifetime of the antenna; Introduction of a collar to suppress electrons.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library