TITLE

Short time ion pulse extraction from the Dresden electron beam ion trap

AUTHOR(S)
Kentsch, U.; Zschornack, G.; Schwan, A.; Ullmann, F.
PUB. DATE
February 2010
SOURCE
Review of Scientific Instruments;Feb2010, Vol. 81 Issue 2, p02A507
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We present measurements of the extraction of short time pulses of highly charged ions (4 keV, Ar16+) from the Dresden electron beam ion trap. Thereby the dependence of the extractable ionic charge on the extraction regime was investigated. The ion extraction time was varied between 20 ns and 1 μs. Furthermore the production of carbon ions and the influence of the extraction regime on the pulse widths was investigated to obtain information about the suitability of the Dresden EBIS-A in synchrotron based particle therapy facilities.
ACCESSION #
48352589

 

Related Articles

  • The Portable Synchrotron MIRRORCLE-6X. Hasegawa, Daisuke; Yamada, Hironari; Kleev, Andrey I.; Toyosugi, Norio; Hayashi, Taichi; Yamada, Takanori; Tohyama, Isao; Young-Deok Ro // AIP Conference Proceedings;2004, Vol. 716 Issue 1, p116 

    The construction of the tabletop synchrotron MIRRORCLE-6X is completed. The electron beam current extracted from the 6-MeV Microtron injector is reached 100 mA with 500 ns pulse duration and 400 Hz repetition rate. The measured main magnetic field distribution of the synchrotron showed good...

  • Extraction of a powerful electron beam into the atmosphere through two parallel titanium foils. Golubenko, Yu. I.; Kuksanov, N. K.; Salimov, R. A.; Nemytov, P. I. // Journal of Applied Mechanics & Technical Physics;Mar2010, Vol. 51 Issue 2, p145 

    This paper described the system used in ELV-6 and ELV-12 industrial accelerators for electron beam extraction into the atmosphere through two parallel titanium foils.

  • Beam Diagnostics for the BNL Energy Recovery Linac Test Facility. Cameron, Peter; Ben-Zvi, Ilan; Blaskiewicz, Michael; Brennan, Michael; Connolly, Roger; Dawson, William; Degen, Chris; DellaPenna, Al; Gassner, David; Kesselman, Martin; Kewish, Jorg; Litvinenko, Vladimir; Mead, Joseph; Oerter, Brian; Russo, Tom; Vetter, Kurt; Yakimenko, Vitaly // AIP Conference Proceedings;2004, Vol. 732 Issue 1, p232 

    An Energy Recovery Linac (ERL) test facility is presently under construction at BNL. The goals of this test facility are first to demonstrate stable intense CW electron beam with parameters typical for the RHIC e-cooling project (and potentially for eRHIC), second to test novel elements of the...

  • Seeded FEL Amplifier-Buncher in the 0.5–9 THz for Advanced Accelerators. Tochitsky, S. Ya.; Reiche, S.; Sung, C.; Rosenzweig, J. B.; Joshi, C.; Gottschalk, S. C.; Kelly, R. // AIP Conference Proceedings;1/22/2008, Vol. 1086 Issue 1, p490 

    Longitudinal modulation of a relativistic electron beam in the THz range is important for advanced laser- or beam-driven plasma accelerators operating in the 1016–1018 cm-3 plasma density range. We describe a single-pass FEL amplifier-buncher which is under construction at the UCLA...

  • Control & Manipulation of Electron Beams. Piot, Philippe // AIP Conference Proceedings;1/22/2008, Vol. 1086 Issue 1, p47 

    The concepts of the advanced accelerators and light source rely on the production of bright electron beams. The rms areas of the beam phase space often need to be tailored to the specific applications. Furthermore, a new class of the forefront research calls for detailed specific distribution...

  • Calculation of Coherent Radiation from Ultra-short Electron Beams Using a Liénard-Wiechert Based Simulation Code. Flacco, A.; Fairchild, M.; Reiche, S.; Rosenzweig, J. B.; Giannessi, L.; Quattromini, M. // AIP Conference Proceedings;2004, Vol. 737 Issue 1, p797 

    The coherent radiation emitted by electrons in high brightness beam-based experiments is important from the viewpoints of both radiation source development, and the understanding and diagnosing the basic physical processes important in beam manipulations at high intensity. While much theoretical...

  • Injection Efficiency Monitor for the Australian Synchrotron. Cole, A.; Boland, M. J.; Van Garderen, E. D.; Rhyder, A.; Rassool, R. P. // EPJ Web of Conferences;2012, Issue 35, preceding p02001-p.2 

    The Australian Synchrotron AS is moving towards a continuous injection mode called top-up. During top-up the linac and booster synchrotron injection system will be in continuous operation rather than used every eight hours the way they are used at present. In order to monitor the performance of...

  • Design of an injector of Super SOR ring. Sakai, Hiroshi; Nakamura, Norio; Takaki, Hiroyuki; Koseki, Tadashi; Hama, Hiroyuki; Shidara, Tetsuo; Satoh, Masanori; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p69 

    We present a design of the injector part for the Super-SOR ring of the University of Tokyo, which is a 3rd generation type vuv light source and is aimed to operate with top-up operation scheme. In order to realize top-up operation, this injector consists of a pre-injector and a synchrotron. The...

  • Measurements of the Beam Induced Heat Load at the ANKA Superconductive Undulator. Casalbuoni, S.; Hagelstein, M.; Kostka, B.; Rossmanith, R.; Schoeck, F.; Weisser, M.; Steffens, E.; Bernhard, A.; Wollmann, D.; Baumbach, T. // AIP Conference Proceedings;2007, Vol. 879 Issue 1, p363 

    Several theoretical papers tried to estimate the magnitude of the different possible effects heating a cold-bore small gap undulator: synchrotron radiation from upstream magnets, image currents and synchrotron radiation produced in the undulator. Measurements performed with the superconducting...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.