TITLE

Sealed operation of a rf driven ion source for a compact neutron generator to be used for associated particle imaging

AUTHOR(S)
Wu, Y.; Hurley, J. P.; Ji, Q.; Kwan, J. W.; Leung, K. N.
PUB. DATE
February 2010
SOURCE
Review of Scientific Instruments;Feb2010, Vol. 81 Issue 2, p02B908
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We present the recent development of a prototype compact neutron generator to be used in conjunction with the method of associated particle imaging for the purpose of active neutron interrogation. In this paper, the performance and device specifications of these compact generators that employ rf driven ion sources will be discussed. Initial measurements of the generator performance include a beam spot size of 1 mm in diameter and a neutron yield of 2×105 n/s with air cooling.
ACCESSION #
48352583

 

Related Articles

  • Simple Penning ion source for laboratory research and development applications. Rovey, Joshua L.; Ruzic, Brandon P.; Houlahan, Thomas J. // Review of Scientific Instruments;Oct2007, Vol. 78 Issue 10, p106101 

    A simple Penning ion generator (PIG) that can be easily fabricated with simple machining skills and standard laboratory accessories is described. The PIG source uses an iron cathode body, samarium cobalt permanent magnet, stainless steel anode, and iron cathode faceplate to generate a plasma...

  • Low-energy beam transport studies supporting the spallation neutron source 1-MW beam operation. Han, B. X.; Kalvas, T.; Tarvainen, O.; Welton, R. F.; Murray, S. N.; Pennisi, T. R.; Santana, M.; Stockli, M. P. // Review of Scientific Instruments;Feb2012, Vol. 83 Issue 2, p02B727 

    The H- injector consisting of a cesium enhanced RF-driven ion source and a 2-lens electrostatic low-energy beam transport (LEBT) system supports the spallation neutron source 1 MW beam operation with ∼38 mA beam current in the linac at 60 Hz with a pulse length of up to ∼1.0 ms. In...

  • Characteristics of an ion beam modification system with a linear ion source. Ide-Ektessabi, Ari; Yasui, Nobuto; Okuyama, Daisuke // Review of Scientific Instruments;Feb2002, Vol. 73 Issue 2, p873 

    Characteristics of an ion beam surface modification system with a linear ion source are described in this article. The linear ion source is principally based on an anode layer thruster, which is generally referred to as "closed drift thruster." The linear ion source has a slit type...

  • Comparison of simulation codes for the beam dynamics of low-energy ions. Hanke, K.; Heising, S.; Probert, G.; Scrivens, R. // Review of Scientific Instruments;Feb2002, Vol. 73 Issue 2, p783 

    Results are presented of the simulation of low-energy ion dynamics with three different codes: KOBRA, IGUN, and CPO. To share work between different codes one needs to be confident that they agree. For test cases, good agreement was found between the codes and analytical solutions. Where...

  • Ion sources for radioactive ion beams in ISOL facilities (plenary). Schmor, P. W. // Review of Scientific Instruments;Feb2002, Vol. 73 Issue 2, p707 

    Research requiring radioactive ion beams (RIBs) are rapidly expanding worldwide. On-line-isotope-separation RIB facilities, in particular, present a unique and challenging environment for ion source operation. Ion sources are required to ionize short-lived isotopes, in a very high radiation...

  • Beam extraction from ion sources with electrostatic containment. Coste, Ph.; Aubert, J.; Farchi, A.; Lejeune, C.; Wartski, L. // Review of Scientific Instruments;Apr92, Vol. 63 Issue 4, p2762 

    Ion sources with electrostatic containment of the primary electrons are very attractive since they possess an upgraded ionization efficiency and are simple to realize. However, their plasma potential is quite different from the potential of the plasma electrode, which supports extraction...

  • Beam diagnostics (invited). Strehl, P. // Review of Scientific Instruments;Apr92, Vol. 63 Issue 4, p2652 

    Although the types of ion sources in many applications are of great diversity the quality of a source can be assessed mostly by the measurement of the same beam parameters. In this paper the characteristics of various devices for measurement of beam currents, beam profiles, and transverse...

  • Investigation of a radio frequency-driven multicusp ion source of the diagnostic neutral beam for the Hanbit device at Korea Basic Science Institute. Yang, H. L.; Yoo, S. J.; Hwang, S. M.; Chung, K. H. // Review of Scientific Instruments;Feb2000, Vol. 71 Issue 2, p1148 

    Describes the first results of the ion bean extraction experiments conducted at Korea Basic Science Institute. Experimental setup; Results; Conclusion.

  • Reversal ion source: A new source of negative ion beams. Orient, O. J.; Chutjian, A.; Alajajian, S. H. // Review of Scientific Instruments;Jan1985, Vol. 56 Issue 1, p69 

    We demonstrate a new type of ion source for producing either pulsed or continuous negative ion beams. The source, dubbed the ‘‘reversal ion source,’’ utilizes an electrostatic ‘‘mirror’’ which reverses trajectories in an electron beam,...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library