ABSTRACT
Superconducting electron cyclotron resonance ion source with advance design in Lanzhou (SECRAL) is an 18–28 GHz fully superconducting electron cyclotron resonance (ECR) ion source dedicated for highly charged heavy ion beam production. SECRAL, with an innovative superconducting magnet structure of solenoid-inside-sextupole and at lower frequency and lower rf power operation, may open a new way for developing compact and reliable high performance superconducting ECR ion source. One of the recent highlights achieved at SECRAL is that some new record beam currents for very high charge states were produced by 18 GHz or 18+14.5 GHz double frequency heating, such as 1 e μA of 129Xe43+, 22 e μA of 209Bi41+, and 1.5 e μA of 209Bi50+. To further enhance the performance of SECRAL, a 24 GHz/7 kW gyrotron microwave generator was installed and SECRAL was tested at 24 GHz. Some promising and exciting results at 24 GHz with new record highly charged ion beam intensities were produced, such as 455 e μA of 129Xe27+ and 152 e μA of 129Xe30+, although the commissioning time was limited within 3–4 weeks and rf power only 3–4 kW. Bremsstrahlung measurements at 24 GHz show that x-ray is much stronger with higher rf frequency, higher rf power. and higher minimum mirror magnetic field (minimum B). Preliminary emittance measurements indicate that SECRAL emittance at 24 GHz is slightly higher that at 18 GHz. SECRAL has been put into routine operation at 18 GHz for heavy ion research facility in Lanzhou (HIRFL) accelerator complex since May 2007. The total operation beam time from SECRAL for HIRFL accelerator has been more than 2000 h, and 129Xe27+, 78Kr19+, 209Bi31+, and 58Ni19+ beams were delivered. All of these new developments, the latest results, and long-term operation for the accelerator have again demonstrated that SECRAL is one of the best in the performance of ECR ion source for highly charged heavy ion beam production. Finally the future development of SECRAL will be presented.
ACCESSION #
48352574

 

Related Articles

  • Roadmap for the design of a superconducting electron cyclotron resonance ion source for Spiral2. Thuillier, T.; Angot, J.; Barué, C.; Canet, C.; Lamy, T.; Lehérissier, P.; Lemagnen, F.; Maunoury, L.; Peaucelle, C. // Review of Scientific Instruments;Feb2012, Vol. 83 Issue 2, p02A339 

    A review of today achieved A/Q = 3 heavy ions beams is proposed. The daily operation A/Q = 3 ion beam intensities expected at Spiral2 are at the limit or above best record 3rd generation electron cyclotron resonance ion source (ECRIS) intensities. The necessity to build a new fully...

  • Concept for a fourth generation electron cyclotron resonance ion source. Lyneis, C.; Ferracin, P.; Caspi, S.; Hodgkinson, A.; Sabbi, G. L. // Review of Scientific Instruments;Feb2012, Vol. 83 Issue 2, p02A301 

    A fourth generation electron cyclotron resonance ion source with an operating frequency between 40 and 56 GHz has the potential to quadruple the heavy-ion beam currents and provide a cost effective upgrade path for heavy ion drivers in use or in the planning stage at radioactive beam facilities....

  • Production of intense 58Fe, 64Ni beam using the MIVOC method and new analyzing system of RIKEN 18 GHz electron cyclotron resonance ion source. Kidera, M.; Nakagawa, T.; Higurashi, Y.; Aihara, T.; Suzuki, N.; Ikezawa, E.; Kamigaito, O.; Kase, M.; Yano, Y. // Review of Scientific Instruments;May2004, Vol. 75 Issue 5, p1473 

    As required by the research group of super heavy elements, highly intense beams of 58Fe and 64Ni ions were produced from RIKEN 18 GHz electron cyclotron resonance ion source [Nakagawa et al., Nucl. Instrum. Methods Phys. Res. A 396, 9 (1997)] using the MIVOC method. Maximum intensities of the...

  • Recent results with the mVINIS ion source. Dobrosavljević, A.; Šljegović, M.; Draganić, I.; Čizmić, B. // Review of Scientific Instruments;May2004, Vol. 75 Issue 5, p1460 

    The mVINIS ion source is a part of the TESLA Accelerator Installation, in Belgrade. It is an ECR ion source used as a stand-alone machine delivering multiply charged ion beams to a low energy experimental channel for modification of materials (the L3A channel). In the future, it will be also...

  • New superconducting electron cyclotron resonance ion source for RIKEN RI beam factory project. Nakagawa, T.; Kidera, M.; Higurashi, Y.; Ohonishi, J.; Goto, A.; Yano, Y. // Review of Scientific Instruments;Feb2008, Vol. 79 Issue 2, p02A327 

    For RIKEN radio isotope beam project, we started to construct the new superconducting electron cyclotron resonance ion source (SC-ECRIS), which has an operational frequency of 28 GHz, in 2007. The main feature of this ion source is that we can produce large size of resonance zone with six sets...

  • Effect of a biased electrode on operation of electron cyclotron resonance ion source using liquid He free superconduction solenoid coils. Imanaka, M.; Kurita, T.; Tsukada, M.; Arai, I.; Lee, S. M.; Nakagawa, T. // Review of Scientific Instruments;Feb2002, Vol. 73 Issue 2, p592 

    We have constructed a liquid He free SC-ECRIS and successfully extracted intense beams of various heavy ions. To improve its performance, we installed a negatively biased electrode in the plasma chamber and observed its effect on the beam intensity systematically. We measured the beam intensity...

  • Ion beam extraction and transport for high-field electron cyclotron resonance ion sources (abstract). Leitner, M. A.; Wutte, D.; Lyneis, C. M. // Review of Scientific Instruments;Feb2002, Vol. 73 Issue 2, p541 

    The next-generation, very high magnetic-field electron cyclotron resonance (ECR) ion sources, like VENUS, SERSE, or PHOENIX, strive for substantially (a factor of 10) higher extracted heavy ion beam intensities than currently achievable. Such high-intensity ion beams present significant...

  • High current density production of multicharged ions with ECR plasma heated by gyrotron transmitter. Bouly, J. L.; Curdy, J. C.; Geller, R.; Golubev, S. V.; Lacoste, A.; Lamy, T.; Sole, P.; Sortais, P.; Razin, S. V.; Vieux-Rochaz, J. L.; Thuillier, T.; Vodopyanov, A. V.; Zorin, V. G. // Review of Scientific Instruments;Feb2002, Vol. 73 Issue 2, p528 

    In order to study the possibilities to produce high currents of pulsed heavy ion beams dedicated to synchrotron injection, two new approaches of ECR devices are now underway. The basic principle consists in maintaining a functioning point of the source with the highest density as possible and a...

  • Intense beam production from RIKEN 18 GHz ECRIS and liquid He free SC-ECRISs. Nakagawa, T.; Kurita, T.; Kidera, M.; Imanaka, M.; Higurashi, Y.; Tsukada, M.; Lee, S. M.; Kase, M.; Yano, Y. // Review of Scientific Instruments;Feb2002, Vol. 73 Issue 2, p513 

    Intense beams of heavy ions with medium charge states (1.3 mA of Ar[sup 8+], 200 µA of Xe[sup 20+]) have been produced from a RIKEN 18 GHz electron cyclotron resonance ion source (ECRIS) using various kinds of techniques, e.g., utilization of an aluminum cylinder and a biased disk, and...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics